Well History
Oil and Gas
|
1983-02-07
|
Issued Date 2/7/83 Expired Date 8/6/83 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03730 Proposed Drill Depth 03730
|
Original Spud
|
1983-02-23
|
|
Completed
|
1983-02-28
|
|
Reached Total Depth
|
1983-02-28
|
|
CO
|
1983-05-31
|
244 SHONGUM OIL & GAS INC GeoDate 2/7/83
|
Completion Report Received
|
1983-06-03
|
|
Construction Permit Expires
|
1983-08-06
|
|
CO
|
1995-04-12
|
43 RESOURCE AMERICA INC GeoDate 2/7/83
|
Change of Owner
|
2004-03-12
|
Operator changed from 43, RESOURCE AMERICA INC to 6867, ATLAS AMERICA INC
|
Change of Owner
|
2011-01-27
|
Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
|
Change of Owner
|
2011-02-08
|
Operator changed from 6867, ATLAS AMERICA LLC to 6866, ATLAS NOBLE LLC
|
Change of Owner
|
2017-10-17
|
Operator changed from 6866, ATLAS NOBLE LLC to 8685, M & R INVESTMENTS OHIO LLC
|
Record Last Modified
|
2017-10-17
|
|
For data sources see[2]
Perforation Treatments
2006-09-11
|
3566
|
3624
|
14
|
|
0
|
|
0
|
1997-06-29
|
0
|
|
0
|
|
3566
|
3624
|
14
|
|
0
|
|
0
|
For data sources see[3]
Stimulations Data
|
H2O
|
0
|
13070 Gal
|
35000
|
|
FRAC: N2-FOAM, 13MG FLUID, 35M SAND
|
For data sources see[4]
Production Data
For data sources see[5]
[6]
Waste Data
For data sources see[7]
[8]
Inspection Data
Inspections Performed
-295981361
|
2015-9-21 0:00:
|
PW
|
No Violations
|
|
000PL11806
|
|
Preliminary Restoration
|
No Violations
|
Preliminary Restoration done information from Data Point
|
0295981361
|
2015-09-21
|
Production Wells
|
No Violations
|
Inspected production well on 09/21/2015. The tank battery consists of 2-210 bbl steel tanks, 2-25 bbl steel tanks, and 2-horizontal separators located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor located within an unlocked metal fence. A small metal tag with well identification information is attached to the wellhead. No problems were noted at the time of the inspection.
|
1042751275
|
2013-08-13
|
Production Wells
|
No Violations
|
This producing plunger lift has no apparent problems at this time.
|
1142526530
|
2006-03-16
|
Production Wells
|
Violations Noted
|
Sharon Township Fire Department called Dave Hodges to report a gas leak at 1200 Fixler Rd , Wadsworth. I arrived at 1200 Fixler and spoke with Tom Boggs. He showed me where the leak was located. It is in the line running from the well to the tank battery. I called Terry Whitehair and advised him of the leak in Tom Boggs yard. I called Sharon Township Fire Department to advise line. is being repaired. Sun, 35 degrees. Fire Department Phone: 330-239-4992, Tom Boggs: 330-239-2676. Terry Whitehair:330-289-4427.
|
1144083652
|
2006-04-03
|
Production Wells
|
Violations Noted
|
Case # 06-001. Underground gas line has been repaired. Well is in production. NOV in compliance. Rain, 55 degrees.
|
2008807065
|
2014-07-24
|
Production Wells
|
No Violations
|
Inspected production well on 07/24/2014. The tank battery consists of 2-210 bbl steel tanks, 2-25 bbl steel tanks, and 2-horizontal separators within an earthen dike. The diked area is located within a locked metal fence. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equiped with a pump jack with an electric motor located within a locked metal fence. Well identification information is posted at the wellhead as required. No problems were noted at the time of the inspection.
|
PL11806
|
|
PL
|
No Violations
|
|
Violations Commited
1142526530
|
US-OH-103621
|
2006-03-16
|
|
Well insufficiently equipped to prevent escape of oil and gas
|
1144083652
|
US-OH-103674
|
2006-03-16
|
|
Well insufficiently equipped to prevent escape of oil and gas
|