{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.16,"lon":-81.81,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Medina | |
Municipality: Medina Township | |
Operator Name: CUTTER OIL COMPANY | |
Well Pad ID: | |
Farm/Lease Name: WEYMOUTH COUNTRY CLUB | |
License Status: Final Restoration | |
License Date: 2013-08-26 | |
Spud Date: 1989-11-13 | |
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]] | |
Final Drill Date: 1989-11-18 | |
Well Total Depth: 3340.00 ft | |
Configuration: Vertical | |
Latitude: 41.160000 | |
Longitude: -81.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1989-09-19 | Issued Date 9/19/89 Expired Date 9/19/90 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03340 Proposed Drill Depth 03340 |
Original Spud | 1989-11-13 | |
Completed | 1989-11-18 | |
Reached Total Depth | 1989-11-18 | |
CO | 1989-11-25 | 1249 CUTTER OIL CO GeoDate 9/19/89 |
Completion Report Received | 1990-12-06 | |
APP | 2013-08-26 | Proposed Formations:CLINTON, Issued Date:8/26/2013, Expired Date:8/26/2015 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2014-01-03 | |
Construction Permit Expires | 2015-08-26 | |
Record Last Modified | 2018-12-19 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3160 | 3240 | 0 |
3160 | 3240 | 0 | |
2006-09-11 | 3198 | 3240 | 2 |
3198 | 3240 | 2 | |
3160 | 3240 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 500 Gal | 70000 | FRAC:WATER/SAND/N2 ASSIST | ||
H2O | 0 | 2400 Bbl | 0 | BREAKDOWN 1000 PSI | ||
N2 | 0 | 250 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | CUTTER OIL COMPANY | 3912.00 | 70.00 | 365 |
1992 | CUTTER OIL COMPANY | 331.00 | 0.00 | 365 |
1993 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
1994 | CUTTER OIL COMPANY | 0.00 | 0.00 | 365 |
1995 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
1996 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
1997 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
1998 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
1999 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2000 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2001 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2002 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2003 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2004 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2005 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2006 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2007 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2008 | CUTTER OIL COMPANY | 0.00 | 0.00 | 0 |
2009 | CUTTER OIL COMPANY | 0.00 | 0.00 | 365 |
2010 | CUTTER OIL COMPANY | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | CUTTER OIL COMPANY | Brine | 157 | 365 |
1992 | CUTTER OIL COMPANY | Brine | 60 | 365 |
1993 | CUTTER OIL COMPANY | Brine | 0 | 0 |
1994 | CUTTER OIL COMPANY | Brine | 0 | 365 |
1995 | CUTTER OIL COMPANY | Brine | 0 | 0 |
1996 | CUTTER OIL COMPANY | Brine | 0 | 0 |
1997 | CUTTER OIL COMPANY | Brine | 0 | 0 |
1998 | CUTTER OIL COMPANY | Brine | 0 | 0 |
1999 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2000 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2001 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2002 | CUTTER OIL COMPANY | Brine | 60 | 0 |
2003 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2004 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2005 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2006 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2007 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2008 | CUTTER OIL COMPANY | Brine | 0 | 0 |
2009 | CUTTER OIL COMPANY | Brine | 0 | 365 |
2010 | CUTTER OIL COMPANY | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL11257 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1429588040 | 2012-08-16 | Production Wells | No Violations | This well was inspected at the request of The Weymouth Country Club, who is attempting a transfer of ownership to them. The well is registered to Cutter Oil; INC. The inspection revealed that the well is powered by a large electric pump that has not been used for approximately 7 years. The country club would like to have the well returned to service for their own use only of heating 1 or 2 buildings on club property. The country club has been discussing the return to service with Cutter Oil. I discussed the well with CJ Cutter, President of Cutter Oil and he says the well has 150 PSI, which I confirmed at the well head by the gauges on the feed lines. The upgrade of the operating equipment would be completed to state requirements following the transfer of the ownership to the country club and with completion of the permitting process. Cutter Oil; INC recommends removing the current 200 barrel tank and replacing it with a 100 barrel tank. Removal of the sales line, and replacing the electric pump with a pump jack. |
1536337723 | 2018-08-10 | Final Restoration | No Violations | Conducted compliance inspection for Final Restoration, this well was plugged on 01-03-2014. The well this field review was conducted with the grounds keeper of Weymouth Country Club he showed me where the well was which is known part of a glufing green. With no visible field evidence or disturbance of any well in this area.
Final Restoration approved |
2007607170 | 2018-08-10 | Final Restoration | No Violations | Conducted inspection of this well site to check for final restoration status well was plugged on 01/03/2014.
Final restoration passed. |
PL11257 | PL | No Violations |