34-103-24562

Well Details

Well ID: 34-103-24562
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Hinckley Township
Operator Name: PINE TOP INC
Well Pad ID:
Farm/Lease Name: MASON
License Status: Producing
License Date: 1989-11-01
Spud Date: 1989-11-02
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1989-11-05
Well Total Depth: 3340.00 ft
Configuration: Vertical
Latitude: 41.270000
Longitude: -81.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1989-11-01 570 PINE TOP INC GeoDate 11/1/89
Oil and Gas 1989-11-01 Issued Date 11/1/89 Expired Date 11/1/90 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03340 Proposed Drill Depth 03340
Original Spud 1989-11-02
Completed 1989-11-05
Reached Total Depth 1989-11-05
Completion Report Received 1989-11-22
Construction Permit Expires 1990-11-01
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3101 3192 0
3101 3192 0
2006-09-11 3146 3162 16
3146 3162 16
3101 3192 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 60000 40000 FRAC:WATER&SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 PINE TOP INC 1443.00 1025.00 202
1991 PINE TOP INC 214.00 705.00 365
1992 PINE TOP INC 274.00 467.00 365
1993 PINE TOP INC 1850.00 235.00 365
1994 PINE TOP INC 758.00 219.00 365
1995 PINE TOP INC 1177.00 182.00 371
1996 PINE TOP INC 881.00 132.00 353
1997 PINE TOP INC 881.00 62.00 353
1998 PINE TOP INC 547.00 129.00 353
1999 PINE TOP INC 245.00 73.00 365
2000 PINE TOP INC 383.00 156.00 365
2001 PINE TOP INC 750.00 170.00 365
2002 PINE TOP INC 998.00 230.00 365
2003 PINE TOP INC 459.00 88.00 365
2004 PINE TOP INC 367.00 158.00 365
2005 PINE TOP INC 452.00 161.00 365
2006 PINE TOP INC 394.00 122.00 365
2007 PINE TOP INC 188.00 84.00 365
2009 PINE TOP INC 238.00 85.00 365
2010 PINE TOP INC 394.00 220.00 365
2011 PINE TOP INC 233.00 143.00 365
2012 PINE TOP INC 293.00 0.00 366
2013 PINE TOP INC 89.00 85.00 365
2014 PINE TOP INC 9.00 31.00 365
2015 PINE TOP INC 0.00 0.00 365
2016 PINE TOP INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 PINE TOP INC Brine 152 202
1991 PINE TOP INC Brine 106 365
1992 PINE TOP INC Brine 30 365
1993 PINE TOP INC Brine 46 365
1994 PINE TOP INC Brine 25 365
1995 PINE TOP INC Brine 0 371
1996 PINE TOP INC Brine 0 353
1997 PINE TOP INC Brine 0 353
1998 PINE TOP INC Brine 0 353
1999 PINE TOP INC Brine 0 365
2000 PINE TOP INC Brine 25 365
2001 PINE TOP INC Brine 44 365
2002 PINE TOP INC Brine 0 365
2003 PINE TOP INC Brine 25 365
2004 PINE TOP INC Brine 0 365
2005 PINE TOP INC Brine 0 365
2006 PINE TOP INC Brine 70 365
2007 PINE TOP INC Brine 63 365
2009 PINE TOP INC Brine 0 365
2010 PINE TOP INC Brine 0 365
2011 PINE TOP INC Brine 0 365
2012 PINE TOP INC Brine 0 366
2013 PINE TOP INC Brine 0 365
2014 PINE TOP INC Brine 0 365
2015 PINE TOP INC Brine 0 365
2016 PINE TOP INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1947100153 2007-5-21 0:00: PW No Violations 1.00
000PL11255 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1177684148 2007-04-27 Production Wells Violations Noted Bob Worstall took a call from Tony Carlisle of Pine Top Inc. 2 flow line leading from well to tank battery, split and discharged 2-3 gallons of crude oil in front yard and road ditch on SR 3 north of Hinckley. Tony notified EPA, Kurt Kollert. Road ditch was flowing due to heavy rains. Siphon dams have been set in ditch and absorbant applied to crude oil in yard. Line is repaired.
1179264775 2007-05-15 Production Wells No Violations Case # 07-007,Followup oil spill. Dry ditch and ground where spill occurred. Advised Tony Carlisle to pickup booms and remove siphon dams. Scrape oil from ditch and grade area, seed and mulch. Sun, 85 degrees.
1402399294 2014-06-05 Production Wells No Violations Inspected production well on 06/05/2014. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, drip, and 1-horizontal separator within an earthen dike; the diked area is located within an unlocked metal fence. Multiple small leaks were noted at the tank connections as well as dirty diapers that will need to be cleaned up. Identification posted at the tank battery indicates that it is used by the Mason #1 well (API#: 34-103-2-4542-00-00), however the tank coordinates listed in RBDMS show that the tank battery is utilized by this well also. Identification will need to be posted at the tank battery for all wells producing into it. The well is equipped with a pump jack with an electric motor located within an unlocked metal fence. Well identification is posted, however none of the well information is correct (wrong county, wrong well, etc.), so it will need to be updated. Cathy with Pine Top, Inc. was notified of these issues and will address them as soon as possible. No other problems were noted at the time of the inspection.
1947100153 2007-05-21 Production Wells No Violations Case # 07-007, requested by Tony Carlisle to inspect site after oil spill cleanup. Oil booms and siphon dams have been removed from SR 3 road ditch. 10 by 5 area in yard has been graded and seeded. Sun 65 degrees.
PL11255 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1177684148 US-OH-104722 2007-04-27 Inadequate pipeline strength
1177684148 US-OH-104723 2007-04-27 Well insufficiently equipped to prevent escape of oil and gas
1177684148 US-OH-104724 2007-04-27 Failure to legibly identify well