X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-24866

Well Details

Well ID: 34-103-24866
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Westfield Township
Operator Name: KING DRILLING CO
Well Pad ID:
Farm/Lease Name: DELAGRANGE DONALD
License Status: Producing
License Date: 2003-11-06
Spud Date: 2004-02-10
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 2004-02-16
Well Total Depth: 5244.00 ft
Configuration: Vertical
Latitude: 41.000000
Longitude: -81.940000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1996-08-19 Issued Date 8/19/96 Expired Date 8/19/97 Acres 0069500 Tool Type RTAF Proposed Formation TREMPEALEAU Proposed Depth 05244 Proposed Drill Depth 05244
Original Spud 1996-10-29
Completed 1996-11-05
CO 1996-12-29 255 KING DRILLING CO GeoDate 8/19/96
APP 2003-11-06 Proposed Formations:CLINTON, Issued Date:11/6/2003, Expired Date:11/5/2004 6:00:00 AM, Drilling unit acres:69.5, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged Back 2004-02-11
Reached Total Depth 2004-02-16
Completion Report Received 2004-03-04
Construction Permit Expires 2004-11-05
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-04-05 2978 3030 15
5222 0
1997-06-29 5222 0
2978 3030 15
2978 3030 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 20000 Gal 0
Not Treated 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1997 KING DRILLING CO 9225.00 0.00 365
1998 KING DRILLING CO 3844.00 0.00 365
1999 KING DRILLING CO 9734.00 0.00 365
2000 KING DRILLING CO 6760.00 0.00 365
2001 KING DRILLING CO 393.00 0.00 365
2002 KING DRILLING CO 542.00 22.00 365
2003 KING DRILLING CO 1642.00 0.00 365
2004 KING DRILLING CO 3593.00 12.00 365
2005 KING DRILLING CO 1886.00 0.00 365
2006 KING DRILLING CO 1472.00 0.00 365
2007 KING DRILLING CO 784.00 0.00 365
2008 KING DRILLING CO 690.00 13.00 365
2009 KING DRILLING CO 656.00 14.00 365
2010 KING DRILLING CO 1032.00 16.00 365
2011 KING DRILLING CO 961.00 17.00 365
2012 KING DRILLING CO 846.00 13.00 366
2013 KING DRILLING CO 634.00 67.00 365
2014 KING DRILLING CO 752.00 40.00 365
2015 KING DRILLING CO 1109.00 31.00 365
2016 KING DRILLING CO 1034.00 41.00 365
2017 KING DRILLING CO 970.00 39.00 365
2018 KING DRILLING CO 885.00 44.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1997 KING DRILLING CO Brine 0 365
1998 KING DRILLING CO Brine 0 365
1999 KING DRILLING CO Brine 0 365
2000 KING DRILLING CO Brine 0 365
2001 KING DRILLING CO Brine 0 365
2002 KING DRILLING CO Brine 160 365
2003 KING DRILLING CO Brine 0 365
2004 KING DRILLING CO Brine 340 365
2005 KING DRILLING CO Brine 0 365
2006 KING DRILLING CO Brine 37 365
2007 KING DRILLING CO Brine 12 365
2008 KING DRILLING CO Brine 0 365
2009 KING DRILLING CO Brine 0 365
2010 KING DRILLING CO Brine 0 365
2011 KING DRILLING CO Brine 0 365
2012 KING DRILLING CO Brine 0 366
2013 KING DRILLING CO Brine 0 365
2014 KING DRILLING CO Brine 0 365
2015 KING DRILLING CO Brine 0 365
2016 KING DRILLING CO Brine 0 365
2017 KING DRILLING CO Brine 0 365
2018 KING DRILLING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1144662968 2015-9-30 0:00: PW No Violations
1144662968 2015-09-30 Production Wells No Violations Inspected production well on 09/30/2015. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator located within an earthen dike. The well is equipped with a pump jack with a gas-powererd motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1206571812 2006-02-21 Preliminary Restoration No Violations Well was plugged back to Clinton formation. Equipped with pump jack, rods and tubing. 1-100 barrel tank with separator in battery. Cloudy, 25 degrees.
1555105081 2014-09-05 Production Wells No Violations Inspected production well on 09/05/2014. The tank battery consists of 1-100 bbl steel tank and 1-vertical separator located within an earthen dike. The well is equipped with a pump jack with a gas-powered motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
iANGE00003 1997-06-12 Preliminary Restoration No Violations
iANGE000034 1997-6-12 0:00: PL No Violations

For data sources see[9]

References