X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-24944

Well Details

Well ID: 34-103-24944
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Chatham Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: GARVER
License Status: Producing
License Date: 2002-02-04
Spud Date: 2002-04-03
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 2002-04-10
Well Total Depth: 360.00 ft
Configuration: Vertical
Latitude: 41.120000
Longitude: -82.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-02-04 Proposed Formations:BEREA, Issued Date:2/4/2002, Expired Date:2/4/2003 6:00:00 AM, Drilling unit acres:26.07, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2002-04-03 RBDMS Rec
Completed 2002-04-10 RBDMS Rec
Reached Total Depth 2002-04-10 RBDMS Rec
Construction Permit Expires 2003-02-04 RBDMS Rec
Completion Report Received 2003-10-06 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 180 Qts 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 HARLEY DRILLING & PRODUCING LT 0.00 27.00 365
2003 HARLEY DRILLING & PRODUCING LT 0.00 0.00 0
2004 HARLEY DRILLING & PRODUCING LT 0.00 77.00 365
2005 HARLEY DRILLING & PRODUCING LT 0.00 0.00 0
2006 HARLEY DRILLING & PRODUCING LT 0.00 55.00 365
2007 HARLEY DRILLING & PRODUCING LT 0.00 54.00 365
2008 HARLEY DRILLING & PRODUCING LT 0.00 49.00 365
2009 HARLEY DRILLING & PRODUCING LT 0.00 55.00 365
2010 HARLEY DRILLING & PRODUCING LT 0.00 18.00 365
2011 HARLEY DRILLING & PRODUCING LT 0.00 38.00 365
2012 HARLEY DRILLING & PRODUCING LT 0.00 26.00 366
2013 HARLEY DRILLING & PRODUCING LT 0.00 26.00 365
2014 HARLEY DRILLING & PRODUCING LT 0.00 26.00 365
2015 HARLEY DRILLING & PRODUCING LT 0.00 24.00 365
2016 HARLEY DRILLING & PRODUCING LT 0.00 34.00 365
2017 HARLEY DRILLING & PRODUCING LT 0.00 24.00 365
2018 HARLEY DRILLING & PRODUCING LT 0.00 55.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 HARLEY DRILLING & PRODUCING LT Brine 39 365
2003 HARLEY DRILLING & PRODUCING LT Brine 0 0
2004 HARLEY DRILLING & PRODUCING LT Brine 0 365
2005 HARLEY DRILLING & PRODUCING LT Brine 0 0
2006 HARLEY DRILLING & PRODUCING LT Brine 16 365
2007 HARLEY DRILLING & PRODUCING LT Brine 9 365
2008 HARLEY DRILLING & PRODUCING LT Brine 23 365
2009 HARLEY DRILLING & PRODUCING LT Brine 32 365
2010 HARLEY DRILLING & PRODUCING LT Brine 10 365
2011 HARLEY DRILLING & PRODUCING LT Brine 52 365
2012 HARLEY DRILLING & PRODUCING LT Brine 13 366
2013 HARLEY DRILLING & PRODUCING LT Brine 6 365
2014 HARLEY DRILLING & PRODUCING LT Brine 5 365
2015 HARLEY DRILLING & PRODUCING LT Brine 8 365
2016 HARLEY DRILLING & PRODUCING LT Brine 4 365
2017 HARLEY DRILLING & PRODUCING LT Brine 18 365
2018 HARLEY DRILLING & PRODUCING LT Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0023479445 2002-08-12 Production Wells No Violations Status check inspection - well just placed into production. Site has been rough graded but not seeded or mulched.
1765704357 2014-06-30 Production Wells No Violations Inspected production well on 06/30/2014. The tank battery consists of 3-100 bbl steel tanks and an underground brine vault located within an earthen dike. A light accumulation of oil and paraffin was noted on the top of the brine vault that will need to be cleaned up. The tank battery is used by multiple wells; identification is posted for several of the wells producing into it, but this well is not listed. The well is equipped with a pump jack with an electric motor. A small amount of paraffin was noted in the area immediately around the wellhead that will need to be cleaned up. No identification is posted at the wellhead as required. Jason Klauss with Harley Drilling was notified of these issues and will address them as soon as possible. No other problems were noted at the time of the inspection.
23479445 2002-8-12 0:00: PW No Violations

For data sources see[8]

References