If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-103-61836 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.11,"lon":-82,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Medina | |
| Municipality: Chatham Township | |
| Operator Name: WROBLESKI CRAIG | |
| Well Pad ID: | |
| Farm/Lease Name: WROBLESKI | |
| License Status: Final Restoration | |
| License Date: 2014-02-21 | |
| Spud Date: | |
| Spud Drilling Contractor: | |
| Final Drill Date: | |
| Well Total Depth: | |
| Configuration: Vertical | |
| Latitude: 41.110000 | |
| Longitude: -82.000000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2014-02-21 | Proposed Formations:, Issued Date:2/21/2014, Expired Date:2/21/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:IO, Proposed Well Class: |
| Change of Owner | 2014-02-21 | Operator changed from 9998, HISTORIC OWNER to 40006, WROBLESKI CRAIG |
| Plugged by Orphan Well Program | 2014-02-27 | Plugged by Orphan Well Program |
| Plugged/Abandoned | 2014-02-27 | INSPECTED BY HAROLD MORAVY ON 12/31/04. MR. WROBLESKI IS PLANNING TO BUILD A HOUSE ON THIS PROPERTY AND FOUND THE WELL.
I&O CN 2010 08 035 WELL LEAKING GAS AT 100 LEL. 8' OVC PIPE INSTELLED VENTING GAS TO ATMOSPHERE. WELL IN WET AREA. SHOULD BE PLUGGED IN COLD WEATHER WHEN GROUND FROZEN. |
| Construction Permit Expires | 2016-02-21 | INSPECTED BY HAROLD MORAVY ON 12/31/04. MR. WROBLESKI IS PLANNING TO BUILD A HOUSE ON THIS PROPERTY AND FOUND THE WELL.
I&O CN 2010 08 035 WELL LEAKING GAS AT 100 LEL. 8' OVC PIPE INSTELLED VENTING GAS TO ATMOSPHERE. WELL IN WET AREA. SHOULD BE PLUGGED IN COLD WEATHER WHEN GROUND FROZEN. |
| Record Last Modified | 2019-06-14 | INSPECTED BY HAROLD MORAVY ON 12/31/04. MR. WROBLESKI IS PLANNING TO BUILD A HOUSE ON THIS PROPERTY AND FOUND THE WELL.
I&O CN 2010 08 035 WELL LEAKING GAS AT 100 LEL. 8' OVC PIPE INSTELLED VENTING GAS TO ATMOSPHERE. WELL IN WET AREA. SHOULD BE PLUGGED IN COLD WEATHER WHEN GROUND FROZEN. |
For data sources see[2]
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1754588781 | 2010-4-15 0:00: | PW | No Violations | 1.00 |
| -2145760128161378 | 2004-12-13 0:00 | OR | No Violations | 1.00 |
| -330259950 | 2015-12-30 0:00 | FR | No Violations | 2.00 |
| -341010910 | 2014-2-25 0:00: | OR | No Violations | |
| -625414149 | 2014-2-26 0:00: | OR | No Violations | |
| 0259808463 | 2010-02-19 | Orphan | No Violations | Due to heavy snow fall, well leak has not been corrected. No gas odor or LELs around well head at this time. Gas is hissing from collar on top of well. Will repair when snow is off. Sun, 25 degrees. |
| 0330259950 | 2015-12-30 | Final Restoration | No Violations | Collecting photographic evidence of final restoration. Final restoration is approved. |
| 0341010910 | 2014-02-25 | Orphan | No Violations | Follow-up inspection on 02/25/14 for contract compliance.
1. The contractor loaded bore hole with fluid to run the log. Appalachian Well service on site to run
logs Bond (VDL), Gamma Ray and Collar locator.
|
| 0345406542 | 2014-02-27 | Orphan | No Violations | Follow-up inspection on 02/27/14 for contract compliance.
1. Checked well for leakage none detected. casing.
END |
| 0561801731 | 2014-03-20 | Plug / Plug Back | No Violations | Visited location on 03/20/2014 at the request of Norburt Lowder to determine status of the location. All rig-related equipment has been removed, and the location has been rough-graded. The gravel pad installed for parking remains on the location. Location is very wet and muddy. |
| 0575812071 | 2014-02-26 | Plug / Plug Back | No Violations | Visited location on 02/26/2014 to witness siphon cement job. Plan was to use siphon string to remove fluid from hole while filling well up with grout. The siphon string plugged up, so the rig ended up topping the well off with grout to surface. |
| 0625414149 | 2014-02-26 | Orphan | No Violations | Follow-up inspection on 02/26/14 for contract compliance.
grout is gravity fed in from the surface. 2. Used a total of 6 yards, of 9 sack grout to fill well bore to surface. 3. Then the well was shut in gas tight. |
| 1097864848 | 2014-02-24 | Plug / Plug Back | No Violations | Arrived at the location on 02/24/2014 to set bottom plug and prepare location visit for from the public later in the day. Visited with officials from the Chatham Fire Department and several members of the public during townhall meeting regarding orphan wells. |
| 1109873485 | 2005-03-03 | Orphan | No Violations | Gas leak has been repaired. Craig Wrobleski will use well when home is built. Sunny,23 degrees. 6 snow. |
| 1209686479 | 2014-06-10 | Final Restoration | No Violations | I completed this follow up inspection on 06/10/2014 for contract compliance.
This well is located in the wooded portion of the property. The areas disturbed during plugging operations have been graded and seeded and vegetation is established. The gravel access area was modified, per landowner request, and restoration of well site and access approved by landowner. Final Restoration completed and approved. |
| 1265051596 | 2010-02-01 | Production Wells | Violations Noted | Called by Chatham Fire Chief, Byron Fike, 330-421-7504. Gas well leaking at 5681 Vandemark Rd. Medina, Ohio. Well and property is owned by Craig Wrobleski. Well is leaking at ground surface thru surface casing. 0% lel but strong odor of gas and crude oil in area. Called Craig Wrobleski to have it repaired by 2-8-2010. Identify well with emergency phone number, permit number, owner name, and county. Called fire chief to advise. Cloudy, 25 degrees. Repair casing leak so odor does not escape. Post identification at well with owner name, permit number, phone number, and county. Apply for domestic well owner status with Division of Mineral Resources Management. 614-265-6900 - Erica Freeman. Failure to |
| 1269538496 | 2010-03-25 | Orphan | No Violations | Met with Chatham township fire chief on location. Well is leaking at 100% lel. Called Craig Wrobleski and gave him two contractors names and numbers to call for well repair. Strong odor of gas in wooded area. Issued NOV on 2-1-2010. Rain, 50 degrees. |
| 1341845901 | 2012-07-05 | Administrative Inspection | No Violations | Received phone call from William Disbro, Fire Chief, Chatham Township in Medina County. He had received several complaints concerning a strong order of gas in this area over the last few days. Met with him on Thursday 07/05/2012 to investigate the problem. Well has 10 PVC pipe with 90 degree ell vented approximately 8 above surface level. Gas discharge is visible at top off pipe. This well has previously been assigned I&O CN 2010 08 035. I referred all info and case folder to Gene Chini and Norburt Lowder on 07/09/2012. |
| 1403796549 | 2014-02-24 | Orphan | No Violations | Follow-up inspection on 02-24-14 for contract compliance.
1. Contractor placed terra-mats over stream and around well site, Rig stage over well .
2. Contractor excavated around well casing and placed a plastic liner around casing.
3. Contractor establish total depth with swabbing tool which will be run through a lubricator (well
head control) on 6 casing to a depth of 505 tripped out.
4. The contractor installed a BOP onto the 6 casing. Then ran 2.375 tubing a depth of 498.
5. Then Cementers attached to the 2.375 tubing then mixed pumped 35 sacks of Class A cement
with a weight of 15.4# to set bottom plug 498 to 300.
6. Then contractor pulled the tubing out and shut well in gas tight.
7. Will be Logging tomorrow morning.
End |
| 1413193385 | 2005-02-09 | Production Wells | Violations Noted | Well is leaking gas fron top of 5 casing. 0% lel 10 from well head. Strong odor of gas in area. Called Craig Wrobleskis old number but it is not working. Unable to find a working number. Drove to address in North Royalton and left card and message to contact me immediately. Cold,snow, 30 degrees. |
| 1754588781 | 2010-04-15 | Production Wells | No Violations | 10 PVC vent pipe and ell has been attached to top of casing and gas is venting 8 above grade. No odor at ground level. Craig Wrobleski has not applied for domestic well ownership at this time. No identification posted. Sun, 80 degrees. |
| 2145760128 | 2004-12-13 | Orphan | No Violations | Mr. Wroblesski is planning to build home on propertyy and found old gas well. He hired a contractor to shut well in on casing. Gas leak has stopped. Snow 30 degrees. |
| 259808463 | 2010-2-19 0:00: | OR | No Violations | 2.00 |
| 345406542 | 2014-2-27 0:00: | OR | No Violations | |
| 561801731 | 2014-3-20 0:00: | PB | No Violations | |
| 575812071 | 2014-2-26 0:00: | PB | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 1265051596 | US-OH-107125 | 2010-02-01 | Well insufficiently equipped to prevent escape of oil and gas | |
| 1265051596 | US-OH-107126 | 2010-02-01 | Failure to legibly identify well | |
| 1265051596 | US-OH-107127 | 2010-02-01 | Well shall be plugged | |
| 1413193385 | US-OH-112151 | 2005-02-10 | Well insufficiently equipped to prevent escape of oil and gas | |
| 1413193385 | US-OH-112152 | 2005-02-10 | Failure to register/obtain or maintain bond/insurance |
For data sources see[3]