{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.07,"lon":-82.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Meigs | |
Municipality: Salisbury Township | |
Operator Name: AMERICAN NATURAL GAS INC | |
Well Pad ID: | |
Farm/Lease Name: NICHOLS CARL | |
License Status: Producing | |
License Date: 2008-04-21 | |
Spud Date: 1982-03-18 | |
Spud Drilling Contractor: | |
Final Drill Date: 1982-03-20 | |
Well Total Depth: 1653.00 ft | |
Configuration: Vertical | |
Latitude: 39.070000 | |
Longitude: -82.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-01-28 | 215 HERALD OIL & GAS CO GeoDate 1/28/82 |
Oil and Gas | 1982-01-28 | Issued Date 1/28/82 Expired Date Acres 0060000 Tool Type RTF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
Reached Total Depth | 1982-03-20 | PERMIT EXPIRED. |
APP | 2008-04-21 | Proposed Formations:BEREA, Issued Date:4/21/2008, Expired Date:4/21/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Construction Permit Expires | 2009-04-21 | PERMIT EXPIRED. |
Change of Owner | 2010-11-03 | Operator changed from 215, HERALD OIL & GAS CO to 8717, AMERICAN NATURAL GAS INC |
Record Last Modified | 2014-01-08 | PERMIT EXPIRED. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | HERALD OIL & GAS CO | 3443.00 | 0.00 | 0 |
1985 | HERALD OIL & GAS CO | 1397.00 | 66.00 | 0 |
1988 | HERALD OIL & GAS CO | 970.00 | 55.00 | 365 |
1990 | HERALD OIL & GAS CO | 708.00 | 0.00 | 365 |
1992 | HERALD OIL & GAS CO | 963.00 | 0.00 | 365 |
1993 | HERALD OIL & GAS CO | 4190.00 | 127.00 | 310 |
1994 | HERALD OIL & GAS CO | 5979.00 | 137.00 | 350 |
1995 | HERALD OIL & GAS CO | 2468.00 | 136.00 | 365 |
1997 | HERALD OIL & GAS CO | 214.00 | 0.00 | 275 |
1998 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2000 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2001 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2002 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2003 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2004 | HERALD OIL & GAS CO | 0.00 | 29.00 | 75 |
2005 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2006 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2007 | HERALD OIL & GAS CO | 0.00 | 0.00 | 0 |
2008 | HERALD OIL & GAS CO | 174.00 | 0.00 | 30 |
2009 | HERALD OIL & GAS CO | 1206.00 | 0.00 | 365 |
2011 | AMERICAN NATURAL GAS INC | 4090.00 | 0.00 | 365 |
2012 | AMERICAN NATURAL GAS INC | 1875.00 | 63.00 | 366 |
2013 | AMERICAN NATURAL GAS INC | 2415.00 | 0.00 | 365 |
2014 | AMERICAN NATURAL GAS INC | 2415.00 | 82.00 | 365 |
2015 | AMERICAN NATURAL GAS INC | 1905.00 | 25.00 | 365 |
2016 | AMERICAN NATURAL GAS INC | 1773.00 | 33.00 | 365 |
2017 | AMERICAN NATURAL GAS INC | 1315.00 | 33.00 | 365 |
2018 | AMERICAN NATURAL GAS INC | 1126.00 | 0.00 | 363 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | HERALD OIL & GAS CO | Brine | 0 | 0 |
1985 | HERALD OIL & GAS CO | Brine | 0 | 0 |
1988 | HERALD OIL & GAS CO | Brine | 1 | 365 |
1990 | HERALD OIL & GAS CO | Brine | 20 | 365 |
1992 | HERALD OIL & GAS CO | Brine | 20 | 365 |
1993 | HERALD OIL & GAS CO | Brine | 350 | 310 |
1994 | HERALD OIL & GAS CO | Brine | 325 | 350 |
1995 | HERALD OIL & GAS CO | Brine | 786 | 365 |
1997 | HERALD OIL & GAS CO | Brine | 30 | 275 |
1998 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2000 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2001 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2002 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2003 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2004 | HERALD OIL & GAS CO | Brine | 0 | 75 |
2005 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2006 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2007 | HERALD OIL & GAS CO | Brine | 0 | 0 |
2008 | HERALD OIL & GAS CO | Brine | 20 | 30 |
2009 | HERALD OIL & GAS CO | Brine | 60 | 365 |
2011 | AMERICAN NATURAL GAS INC | Brine | 120 | 365 |
2012 | AMERICAN NATURAL GAS INC | Brine | 120 | 366 |
2013 | AMERICAN NATURAL GAS INC | Brine | 120 | 365 |
2014 | AMERICAN NATURAL GAS INC | Brine | 120 | 365 |
2015 | AMERICAN NATURAL GAS INC | Brine | 4370 | 365 |
2016 | AMERICAN NATURAL GAS INC | Brine | 4370 | 365 |
2017 | AMERICAN NATURAL GAS INC | Brine | 3783 | 365 |
2018 | AMERICAN NATURAL GAS INC | Brine | 3228 | 363 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-102528007 | 2018-11-1 0:00: | PW | No Violations | 0.40 |
-144590832 | 2011-4-11 0:00: | PW | No Violations | 1.50 |
-1637678949 | 2019-6-20 0:00: | PW | No Violations | 0.50 |
-1792128643 | 2011-10-31 0:00 | PW | No Violations | 0.50 |
-1873043741 | 2011-8-23 0:00: | PW | No Violations | 0.20 |
-193701358 | 2012-5-10 0:00: | PW | No Violations | 1.00 |
-1937153077 | 2012-5-7 0:00:0 | PW | No Violations | 2.30 |
-194489422 | 2012-5-7 0:00:0 | PW | No Violations | |
-1971869077 | 2012-5-11 0:00: | PW | No Violations | 0.80 |
0102528007 | 2018-11-01 | Production Wells | Violations Noted | The well was equipped with a pumping unit, tubing, rods and an electric motor. The tank battery had 5-100 barrel steel tanks and 1-90 barrel plastic tank. There was 2 vertical separators and a transfer pump in the dike as well. The wellhead and the tank battery will need properly identified. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. If multiple wells are being produced into the common tank(s) each well-head shall be identified as to owner, permit number where available, well number and lease name. |
0144590832 | 2011-04-11 | Production Wells | No Violations | Follow up to inspection #1302011463 .Weak areas of dike had been strengthened and a plastic liner had been added to dike to prevent seepage. Defective tank had been replaced. Contaminated soil area did not appear to have been reseeded yet. |
0193701358 | 2012-05-10 | Production Wells | No Violations | I met with Harmon well service who will be performing the work on the dike at the tank battery. We discussed the removal of contaminated soils as well as repair and/or reconstruction of the dike to ensure it does not allow fluids to leak through. |
0194489422 | 2012-05-07 | Production Wells | No Violations | Accompanied Inspector Josh Garland on inspection of tank dike and brine contamination. |
0286985513 | 2012-05-15 | Production Wells | No Violations | Contaminated soils have been removed from inside and outside of dike. The dike has not yet been fully repaired, but is capable of containing fluids at full capacity. |
1302011463 | 2011-03-25 | Production Wells | Violations Noted | Upon inspection dike around well was found to be full of brine and a seep had developed on the lower side of the dike. It was difficult to tell where the brine had originated. Brine had escaped and contaminated a large area roughly 35x45. A high end Quan-tab was used and the brine outside of the dike registered a 3.6 reading, even after a recent rain event. Bob Adams from American Natural Gas was called and a truck was immediately sent to drain the dike. The affected soil in the area must be removed, reseeded, and mulched. |
1328541346 | 2012-02-06 | Production Wells | No Violations | The bare area has still not been reseeded. I spoke with Bob Adams about getting this area reseeded. |
1336161862 | 2012-05-04 | Production Wells | No Violations | Area outside of dike still bare. |
1337609484 | 2012-05-21 | Production Wells | No Violations | The repairs to the dike have been completed. All the contaminated soils have been removed. The drain has been replaced. Vegetative cover not yet established. |
1343816489 | 2008-02-22 | Production Wells | Violations Noted | An inspection found the well shut-in and incapable of production. The bridle and motor were missing from the unit. There was a gulley, over a foot deep, that ran the length of the lease road. Water was pooling inside the tank battery dike. |
1442440531 | 2012-05-30 | Production Wells | No Violations | Area seeded and mulched. |
1604794632 | 2019-11-13 0:00 | PW | No Violations | 0.50 |
1792128643 | 2011-10-31 | Production Wells | No Violations | Bare area by dike still has not been reseeded. Belt from engine to pump jack broken. Called office to let them know. |
1873043741 | 2011-08-23 | Production Wells | No Violations | Compliance follow up. Dike in good shape. No evidence the ground has been reseeded or mulched. Called Bob Adams of ANG and informed him of continued violation. |
1882725500 | 2011-03-30 | Production Wells | No Violations | Follow up to inspection #1302011463 . Upon inspection dike was found to be full of brine again. I spoke with BJ Daniel of American Natural Gas and truck was brought in to pump out dike. After the dike had been pumped again it was noticed a brine tank was leaking, the tank was emptied and its contents were moved to a good tank. An extension was granted to make corrections to the dike and restorations to ground. |
1930401839 | 2012-05-16 | Production Wells | No Violations | No further work has been done to the dike. |
1937153077 | 2012-05-07 | Production Wells | Violations Noted | A large area, roughly 50 square feet beside the dike, was void of vegetation. A field test was administer to search for the presence of Chlorides and the soil in the areas was found to have 4256 ppm Chlorides. A small seep was noticed on the West side of the dike and the area was found to have 336 ppm Chlorides. The areas below the seep was void of vegetation as well. The pit liner used in the dike was compromised in at least on place. The drain had a slow drip, the water dripping from the drain had 664 ppm Chlorides. All contaminated soils shall be removed and disposed of properly. Affected area shall be reseeded and mulched, and steps shall be taken to encourage vegetative cover. Earthen dike shall be repaired in a manner that does not allow the escape of fluids. Dike drain shall be repaired or replaced. |
1971869077 | 2012-05-11 | Production Wells | No Violations | Dike being repaired. |
286985513 | 2012-5-15 0:00: | PW | No Violations | 0.50 |
746694753 | 2020-4-21 0:00: | PW | No Violations | 0.20 |
975436627 | 2020-4-6 0:00:0 | PW | No Violations | 0.30 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0102528007 | US-OH-100295 | 2018-11-05 | 9-9-05(A)10 | Failure to legibly identify well |
1302011463 | US-OH-108520 | 2011-04-05 | Dike or pit not able to prevent escape of brine or other wastes | |
1343816489 | US-OH-109931 | 2008-03-24 | Failure to restore land surface within 9 mos. (CHANGE) (REPLACE) | |
1343816489 | US-OH-109932 | 2008-03-24 | No SPCC dike/or failure to keep dike free of water or oil | |
1343816489 | US-OH-109933 | 2008-03-24 | Well shall be plugged | |
1937153077 | US-OH-119494 | 2012-05-09 | Well operation causing pollution and contamination | |
1937153077 | US-OH-119495 | 2012-05-09 | Dike or pit not able to prevent escape of brine or other wastes |