If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-105-22739 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.01,"lon":-82.08,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Meigs | |
Municipality: Salisbury Township | |
Operator Name: J D DRILLING COMPANY | |
Well Pad ID: | |
Farm/Lease Name: FORREST EDITH | |
License Status: Active Injection | |
License Date: 1986-08-25 | |
Spud Date: 1983-08-04 | |
Spud Drilling Contractor: D H F DRILLING | |
Final Drill Date: 1983-08-12 | |
Well Total Depth: 4395.00 ft | |
Configuration: Vertical | |
Latitude: 39.010000 | |
Longitude: -82.080000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Salt Water Injection Well | 1983-07-14 | Issued Date 7/14/83 Expired Date 1/10/84 Acres 0065000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04395 Proposed Drill Depth 04395 |
Storage Well | 1983-07-14 | Issued Date 7/14/83 Expired Date 1/10/84 Acres 0065000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04395 Proposed Drill Depth 04395 |
Original Spud | 1983-08-04 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Completed | 1983-08-12 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Reached Total Depth | 1983-08-12 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
CO | 1983-09-29 | 116 J D DRILLING CO GeoDate 7/14/83 |
First Injection | 1983-10-02 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Completion Report Received | 1983-10-03 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
CO | 1986-08-25 | 116 J D DRILLING CO GeoDate 8/25/86 |
Conversion to Injector | 1986-08-25 | |
Salt Water Injection Well | 1986-08-25 | Issued Date 8/25/86 Expired Date 8/25/87 Acres 0065000 Tool Type RTA Proposed Formation MARCELLUS Proposed Depth 00000 Proposed Drill Depth 00000 |
Storage Well | 1986-08-25 | Issued Date 8/25/86 Expired Date 8/25/87 Acres 0065000 Tool Type RTA Proposed Formation MARCELLUS Proposed Depth 00000 Proposed Drill Depth 00000 |
Plugged Back | 1986-08-30 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Annulus Pressure Monitoring Approved | 1987-02-20 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Construction Permit Expires | 1987-08-25 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
CO | 1994-05-02 | 4807 OHIO BEAR INC GeoDate 8/25/86 |
CO | 1996-07-05 | 116 J D DRILLING CO GeoDate 8/25/86 |
Last Compliance Report | 2005-07-15 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
Record Last Modified | 2017-10-19 | PLUGGED BACK FROM CLINTON INJECTION ZONE |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-01 | 3020 | 3088 | 0 |
4303 | 4313 | 4 | |
1999-06-15 | 4303 | 4313 | 4 |
3020 | 3088 | 0 | |
4304 | 4313 | 40 | |
3020 | 3088 | 0 | |
2006-09-11 | 4304 | 4313 | 40 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 500 Gal | 25 | FRAC: WATER, ACID |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1050959132 | 2012-5-7 0:00:0 | SW | No Violations | |
-1075496536 | 2003-6-25 0:00: | SW | No Violations | |
-1112700367 | 2017-5-15 0:00: | SW | No Violations | |
-1159909446 | 2013-12-11 0:00 | SW | No Violations | 0.30 |
-1189460709 | 2016-3-2 0:00:0 | SW | No Violations | |
-119190064 | 2016-2-8 0:00:0 | SW | No Violations | 1.50 |
-1243624300 | 2009-3-11 0:00: | SW | No Violations | |
-1347029176 | 2015-8-12 0:00: | SW | No Violations | 1.50 |
-1482055562 | 2017-2-3 0:00:0 | SW | No Violations | 8.50 |
-1559735526 | 2003-3-5 0:00:0 | SW | No Violations | |
-15862736 | 2014-10-7 0:00: | SW | No Violations | |
-1610057809 | 2019-4-3 0:00:0 | SW | No Violations | 0.50 |
-1676448743 | 2013-6-6 0:00:0 | SW | No Violations | |
-168336236 | 2015-8-7 0:00:0 | SC | No Violations | 2.00 |
-1689091629 | 2005-7-13 0:00: | SW | No Violations | |
-170118489 | 2020-3-5 0:00:0 | SW | No Violations | |
-1712217540 | 2018-12-6 0:00: | SW | No Violations | 2.00 |
-1742995665 | 2016-9-19 0:00: | SW | No Violations | 2.50 |
-1788570732 | 2017-2-7 0:00:0 | SW | No Violations | 2.50 |
-1828429915 | 2004-10-8 0:00: | SW | No Violations | |
-1840395099 | 2015-3-12 0:00: | SW | No Violations | 0.80 |
-1931432038 | 2010-11-24 0:00 | SW | No Violations | |
-1976532510 | 2007-10-22 0:00 | SW | No Violations | |
-1995319957 | 2004-8-17 0:00: | SW | No Violations | |
-2022624148 | 2017-3-23 0:00: | SW | No Violations | 8.50 |
-2026069320 | 2009-6-8 0:00:0 | SW | No Violations | |
-2066280206 | 2006-12-18 0:00 | SW | No Violations | |
-209118733 | 2007-2-16 0:00: | SW | No Violations | |
-2140548443 | 2005-1-13 0:00: | SW | No Violations | |
-249364216 | 2012-6-25 0:00: | SW | No Violations | 0.30 |
-266417797 | 2011-10-24 0:00 | SW | No Violations | 0.70 |
-271031485 | 2016-6-8 0:00:0 | SW | No Violations | 1.50 |
-287124112 | 2018-2-16 0:00: | SW | No Violations | |
-305226523 | 2017-8-29 0:00: | SW | No Violations | 1.20 |
-34519132 | 2004-5-3 0:00:0 | SW | No Violations | |
-395167730 | 2010-3-18 0:00: | SW | No Violations | |
-431416973 | 2010-9-27 0:00: | SW | No Violations | 1.00 |
-436559867 | 2017-4-12 0:00: | SC | No Violations | 2.50 |
-459749770 | 2020-5-6 0:00:0 | SW | No Violations | |
-47692448 | 2015-10-23 0:00 | SW | No Violations | 0.30 |
-481902171 | 2015-10-6 0:00: | SC | No Violations | 1.00 |
-491779347 | 2006-7-11 0:00: | SW | No Violations | |
-493448743 | 2007-7-17 0:00: | SW | No Violations | |
-560067748 | 2016-7-26 0:00: | SW | No Violations | 2.50 |
-585512676 | 2006-5-17 0:00: | SW | No Violations | |
-586633961 | 2018-11-2 0:00: | SW | No Violations | 2.10 |
-591792814 | 2011-3-8 0:00:0 | SW | No Violations | |
-641419758 | 2014-11-24 0:00 | SW | No Violations | 1.00 |
-65328909 | 2016-9-13 0:00: | SW | No Violations | 2.50 |
-671326736 | 2015-7-10 0:00: | SW | No Violations | |
-740712160 | 2015-8-18 0:00: | SW | No Violations | 1.00 |
-741329124 | 2016-12-20 0:00 | SW | No Violations | 0.50 |
-743677823 | 2018-10-9 0:00: | SW | No Violations | 1.00 |
-761696616 | 2006-8-14 0:00: | SW | No Violations | |
-829388140 | 2008-2-25 0:00: | SW | No Violations | |
-864568170 | 2016-10-27 0:00 | SW | No Violations | 1.00 |
-871204534 | 2016-5-26 0:00: | SW | No Violations | 2.50 |
-87332303 | 2019-1-8 0:00:0 | SW | No Violations | 0.50 |
-938759043 | 2015-8-31 0:00: | SC | No Violations | 2.50 |
-955966520 | 2016-9-22 0:00: | SW | No Violations | 3.00 |
0000UIC109 | 1987-02-02 | Salt Water Injection Well | No Violations | 1501:9-3-07 (D)(1)(E) |
0000UIC120 | 1987-03-09 | Salt Water Injection Well | No Violations | 1501:9-3-07(E)&(F) |
000PL10998 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0015862736 | 2014-10-07 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2010, 2011, 2012, and 2013. The Disposal Fee Report for the 3rd and 4th Quarter of 2013 also needs to be filed. |
0034519132 | 2004-05-03 | Salt Water Injection Well | Violations Noted | Unable to measure the pressure on the tubing, because the valve is corroded shut. |
0047692448 | 2015-10-23 | Salt Water Injection Well | No Violations | No noted violations. |
0065328909 | 2016-09-13 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 follow up inspection. There has been no effort made to retrieve the wellhead slip and to retrieve the parted tubing. The well is shut in. The JD Drilling service rig is on the well with the mast up. I talked to Jonathan Reese and he told me that they picked up the magnetic tool from the fabricator. They have not scheduled the service rig crew to work on the well. |
0085239448 | 2003-05-20 | Salt Water Injection Well | No Violations | Violation at tank battery, Steve Ochs will issue the NOV. |
0087332303 | 2019-01-08 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
0103151755 | 2006-08-16 | Salt Water Injection Well | No Violations | The dike still needs some cleane-up work. |
0107140761 | 2015-07-14 | Salt Water Injection Well | No Violations | Follow up to -671326736. met with field supervisor to discuss remediation of the outstanding violation of cracked dike. |
0119190064 | 2016-02-08 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. |
0168336236 | 2015-08-07 | Surface Facility Construction | No Violations | Currently cleaning out the containment dike and repairing and sealing cracks. Reviewed plans for the containment repairs with Tom Schoonover. |
0188519530 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. Form 204 received 7/13/2017 |
0209118733 | 2007-02-16 | Salt Water Injection Well | No Violations | No violations were found. |
0225544723 | 2007-09-10 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0228473619 | 2017-02-23 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 follow up inspection. 2 3/8 tubing is in the 5 casing head. The service rig is on the well with mast up. No one on site during the inspection. A 2 inch black plastic line has been connected to the outlet of the filter housing. I called and asked Jonathan Reese about this line. He told me that the line is being used to transfer brine from the Forest Facility to the Brinker Injection well facility 34-105-23185. |
0249364216 | 2012-06-25 | Salt Water Injection Well | No Violations | No violations. |
0266417797 | 2011-10-24 | Salt Water Injection Well | No Violations | Accompanied J. Scott on SWIW inspection. No violations. |
0271031485 | 2016-06-08 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 Follow up inspection. JD Drilling Service rig is on site with the mast up. No attempt has been made to release the packer and pull the tubing. The injection line is disconnected from the well between the pump and filter housing. Tubing master valve and annulus valve are closed. |
0287124112 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. Reports received 5/14/2018 |
0292008693 | 2017-01-17 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 Follow up inspection. The containment dike has 12 inches of water in it with a skim coating of oil. The well is equipped with a 5.5 inch by 2 inch swedge with a valve. JD Drilling service rig is on the well with the mast up. The injection tubing is stacked on site. Jonathan Reese (JD Drilling field supervisor) was contacted about the water and oil in the containment dike. He was instructed to pump out the dike and haul the fluids to an approved injection well. |
0305226523 | 2017-08-29 | Salt Water Injection Well | No Violations | My inspection today revealed the annulus pressure was 900 psi, the injection pressure was 0 psi. The containment dike was free of fluids. No violations noted. |
0339358181 | 2005-06-29 | Salt Water Injection Well | No Violations | Attempted MIT on well. Unable to pressurize annulus. |
0378612605 | 2007-04-12 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0395167730 | 2010-03-18 | Salt Water Injection Well | No Violations | Good identification. No violations at the time of inspection. |
0429911517 | 2009-05-07 | Salt Water Injection Well | No Violations | There were no violations. |
0431416973 | 2010-09-27 | Salt Water Injection Well | No Violations | Good identification on tank. |
0436559867 | 2017-04-12 | Surface Facility Construction | No Violations | No work has been done to prepare the containment dike for repairs. Concrete needs to be poured in two areas that were cut out during the recent well workover. The injection tubing is disconnected from the injection equipment at the facility. |
0437121172 | 2016-03-22 | Salt Water Injection Well | Violations Noted | Received notification from Jonathan Reese that the annulus was not able to be filled up to test. The well is shut in waiting on service rig to move to the location. |
0460588448 | 2016-08-31 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 Follow up inspection. There are 9 joints of injection tubing stacked by the well. The threads of one joint are clearly broken. The tally on the parted tubing is 282 feet. Currently rigged up and waiting on a fishing tool to be fabricated to retrieve the piece of the well head slip from inside the 5.5 inch casing. |
0481902171 | 2015-10-06 | Surface Facility Construction | No Violations | Inspected the surface facility with UIC Section Geologist. Measured containment dike and documented tank connections. |
0482761561 | 2005-06-16 | Salt Water Injection Well | No Violations | Initially, the pressure readings on the tubing and 4 1/2 inch casing were 0 and 20 psi., respectively.
As the annular pressure on the 4 1/2 was increased, the tubing pressure increased 20 psi. Instructed the well owners representative (Spencer Carpenter) to shut down the operation and requested a suspension order. |
0491779347 | 2006-07-11 | Salt Water Injection Well | Violations Noted | Old tanks were removed from the concrete dike. During this process, oil and waste water were allowed to accumulate inside the dike. |
0493448743 | 2007-07-17 | Salt Water Injection Well | No Violations | There were no violations at the time. |
0500521118 | 2009-08-18 | Salt Water Injection Well | No Violations | Good identification. Concrete dike has cracks that need to be patched. I told Spence Carpenter about the dike repairs that are needed. |
0516505157 | 2016-09-09 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 Follow up inspection. JD Drilling service rig is on the well with the mast up. The wellhead is shut in. Currently waiting on the fabrication of a magnetic fishing tool to retrieve the piece of the wellhead slip. |
0560067748 | 2016-07-26 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 follow up inspection. JD Drilling service rig is on site with mast up. The injection tubing and packer have not been removed from the well. Tom Schoonover was on site with a water truck removing the water from the containment dike. The injection tubing is disconnected from the injection line. |
0585512676 | 2006-05-17 | Salt Water Injection Well | No Violations | There were no violations at this time. |
0585581282 | 2012-09-12 | Salt Water Injection Well | No Violations | The cracks and the dike have been partially sealed. I spoke with Jonathan Reese about finishing the work and granted an extension to 9/17/12. |
0586633961 | 2018-11-02 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
0591792814 | 2011-03-08 | Salt Water Injection Well | Violations Noted | Injection tubing has rust scaling off of it. Injection tubing appears to have a pin hole in the side near the 4.5 casing head. I called and talked to Jonathan Reese and told him my findings and requested that they look at the injection tubing and correct the problems. |
0630792659 | 2003-12-04 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
0641419758 | 2014-11-24 | Salt Water Injection Well | No Violations | No noted violations at facility. |
0651281734 | 2016-08-24 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 Follow up. Pulled 45,000 pounds tension on the tubing and packer. Replaced 5.5 inch wellhead. |
0671326736 | 2015-07-10 | Salt Water Injection Well | Violations Noted | Containment dike is cracked in multiple areas with vegetation growing up through the cracks. 6-12 water in dike. Concrete dike shall be repaired or replaced in order to contain fluids. Dike shall be kept reasonably free of all fluids to maintain capacity in the event of a spill. I met with JD Drilling field supervisor to discuss violations and remediation. |
0691691163 | 2005-07-07 | Salt Water Injection Well | No Violations | |
0705879725 | 2005-10-26 | Salt Water Injection Well | No Violations | The dike, around the wellhead, was repaired with cement. No violations at the time. |
0740712160 | 2015-08-18 | Salt Water Injection Well | No Violations | Follow up to -671326736. The large degraded areas have been replaced with new concrete slabs, sealant was used to close the gaps between the old pad and the new slabs. |
0741329124 | 2016-12-20 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 follow up inspection. The JD Drilling service rig is on the well (mast up). The well is shut in with a 5.5 by 2 swedge and a 2 valve. 2 3/8 tubing is stacked by the well. |
0741923698 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
0743677823 | 2018-10-09 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. There are 7 new- 400 barrel tanks on the location. |
0757362892 | 2018-09-18 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. |
0758544633 | 2018-11-07 | Surface Facility Construction | No Violations | Measuring the containment dike dimensions for UIC Section and taking pictures of the site for UIC Geologist. This is in reference to a proposed facility change submitted by JD Drilling. |
0761696616 | 2006-08-14 | Salt Water Injection Well | No Violations | Unable to measure pressures, because the pump was operating. |
0779827391 | 2017-02-06 | Salt Water Injection Well | No Violations | Mr. Jonathon Reese with J D Drilling called me and said that they were able to get the well to test at 2,390. He asked if I could come down the following morning to preform a MIT test. I said that I could but that was way above their variance and would probably not get approved. |
0812551808 | 2006-11-06 | Salt Water Injection Well | No Violations | Clean-up complete. New tanks were installed. Accompanied by Jon Scott. |
0829388140 | 2008-02-25 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0864568170 | 2016-10-27 | Salt Water Injection Well | No Violations | Compliance notice # 43712172 follow up inspection. Well is equipped with a 5.5 inch by 2 inch swedge with a 2 inch valve (closed). The service rig is on the well with mast up. The injection tubing has been removed from the location. |
0867109566 | 2006-03-29 | Salt Water Injection Well | No Violations | Pressures were measured while the pump was in operation. |
0871204534 | 2016-05-26 | Salt Water Injection Well | No Violations | Compliance notice # 437121172 follow up inspection. A JD Drilling service rig is on site. No rig crew on site. The tubing and packer have not been removed from the well. The containment dike has brine from a 100 barrel tank that was overflowed. I contacted Jonathan Reese and told him to remove all fluids from the dike. The injection line is disconnected from the injection tubing. All valves are closed. |
0898098164 | 2018-03-14 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 0 psi on the tubing and 540 psi on the annulus. The dike was free of fluids. Legible identification was posted. |
0938759043 | 2015-08-31 | Surface Facility Construction | No Violations | Containment dike cracks have been repaired and the dike has been sealed. |
0942925581 | 2003-05-20 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # 1056651171 An inspection revealed a leaking storage tank, inside the dike. Brine was dripping from a man way plate at the base of the tank. Notified the superintendent. |
0955966520 | 2016-09-22 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 follow up inspection. Service rig has retrieved the tubing and packer. Jonathan Reese told me that the new packer has been ordered. Packer job has not been scheduled. |
0975640246 | 2006-10-18 | Salt Water Injection Well | No Violations | Water and oil inside the tank battery dike. |
0991091813 | 2014-10-27 | Salt Water Injection Well | No Violations | Compliance Notice satisfied. All reports requested received. |
0991614811 | 2015-06-09 | Salt Water Injection Well | No Violations | No noted violations. |
103151755 | 2006-8-16 0:00: | SW | No Violations | |
1050309932 | 2006-09-14 | Salt Water Injection Well | No Violations | Dike needs cleaned out. |
1050959132 | 2012-05-07 | Salt Water Injection Well | Violations Noted | Injection pump running during inspection. Pump is leaking brine into dike. Dike has 4 inches of water in it. Used brine filters are being stored out side the dike. I talked to Jonathan Reese and told him to pump out the dike and to remove the filters and dispose of them in a land fill. Jonathan told me that their sump pump has been stolen and they have ordered a rebuild kit for the injection pump. Jonathan told me he will send a vacuum truck to clean out the dike. |
1056651171 | 2003-05-20 | Salt Water Injection Well | Violations Noted | An inspection revealed a leaking storage tank, inside the dike. Brine was dripping from a man way plate at the base of the tank. Notified the superintendent. |
107140761 | 2015-7-14 0:00: | SW | No Violations | 0.50 |
1075496536 | 2003-06-25 | Salt Water Injection Well | Violations Noted | An inspection revealed a leaking storage tank, inside the dike. There was a stream coming from a pin hole in the side of the tank. The dike was over half full of brine. The stop valve on top of the injection tubing is inoperative.
The following action is required: The tank and dike need emptied. The tank needs repaired or replaced. The valve needs repaired or replaced. |
1080059644 | 2004-03-19 | Salt Water Injection Well | No Violations | Zero pressure measured on the tubing and tubing/casing annulus. Well Lat and Long update. |
1081862649 | 2004-04-08 | Salt Water Injection Well | No Violations | Bad valve on tubing. |
1086930932 | 2014-07-24 | Salt Water Injection Well | No Violations | No noted violations. |
1095506847 | 2013-07-17 | Salt Water Injection Well | No Violations | Cracks in dike have been resealed with tar. Sump pump electrical hook up has been improved upon, but the pump does not appear to be in operation. |
1112700367 | 2017-05-15 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017.REPORTS RECEIVED 7/3/2017 |
1126307723 | 2009-11-24 | Salt Water Injection Well | No Violations | Has identification. No violations observed during inspection. |
1140947552 | 2005-05-06 | Salt Water Injection Well | Violations Noted | |
1159909446 | 2013-12-11 | Salt Water Injection Well | No Violations | No note violations. Pump running durring inspection. |
1177424647 | 2018-12-06 | Salt Water Injection Well | Violations Noted | A 2 inch drain valve on a 100 barrel steel tank in the containment dike separated and was draining oil and brine into the containment dike. I contacted Tom Schoonover and Jonathan Reese about the leak. The tank drain valve needs replaced and the fluid in the dike needs to be removed and placed in a tank for disposal. |
1187018733 | 2015-09-01 | Salt Water Injection Well | No Violations | New slabs have been poured in the areas of the dike that needed replacing and sealant was used between the old slab and the new. A vinyl black top patch was used to seal any remaining small cracks in the dike and the entire dike had been cleaned and sealed with blacktop. |
1189460709 | 2016-03-02 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED 3/18/2016. |
1243624300 | 2009-03-11 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
1283644868 | 2006-10-04 | Salt Water Injection Well | No Violations | |
1310959146 | 2018-05-04 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Form 204 received 6/21/2018 |
1320784465 | 2008-09-17 | Salt Water Injection Well | No Violations | There were no violations found at the time of inspection. |
1341044791 | 2014-05-20 | Salt Water Injection Well | No Violations | No noted violations. Pump running durring inspection. |
1345581844 | 2012-08-21 | Salt Water Injection Well | Violations Noted | Cracks are developing in the concrete pad inside the dike. Cracks shall be sealed or dike shall be replaced. Water had accumulated in the dike and the sump pump did not appear to be operating. The dike shall be emptied of all fluids. |
1347029176 | 2015-08-12 | Salt Water Injection Well | No Violations | Follow up to -671326736. Large degraded sections of the concrete were being cut from the sides of the poured dike in order to repair those sections. |
1348164146 | 2012-09-17 | Salt Water Injection Well | No Violations | Cracks had been filled in and the dike had been sealed. The leaky valve had been replaced. There were no fluid in the dike. |
1358527785 | 2013-01-18 | Salt Water Injection Well | No Violations | The large area roughly 20x20 along the entry to the site is void of vegetative cover. The area is just down hill and to the side of the dike. The area was field tested for Chloride content with a high range Quan-tab. The tab read a score of .6 on a scale of 0-10. This is well below 250 ppm Chloride. |
1359125881 | 2013-01-23 | Salt Water Injection Well | No Violations | Inspected surface facility and checked the injection tubing pressure and annulus pressure. Good identification on tank. Injection pump was not operating during inspection. |
1365692598 | 2013-04-08 | Salt Water Injection Well | No Violations | Inspected containment dike, injection pressure and annulus pressure. Good identification on tank. Injection pump has new electric lines ran in waterproof conduit. |
1421022908 | 2019-05-23 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike is free of fluids. There are seven new 400 barrel tanks on location. The tanks are on their side and not in use. A single strand of an electric service line from the Forest pole to a production wellsite on the lease is on the ground. Jonathan Reese was contacted about the electric line. |
1437474159 | 2014-02-28 | Salt Water Injection Well | No Violations | No noted violations. |
1438975216 | 2015-08-07 | Salt Water Injection Well | No Violations | Follow up to -671326736. the dike is in the process of being cleaned so the cracks can be patched thoroughly. |
1439834020 | 2015-08-17 | Salt Water Injection Well | No Violations | Currently cleaning containment dike. Have replaced portions of the concrete containment dike. Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. |
1457348374 | 2018-12-12 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted on tank. The containment dike fluid level is down to the low area by the sump. Oil reside is scattered inside the containment dike. The injection pump motor belt has broken. The electric motor was running during the inspection. The filter housing drain valve is leaking brine into the containment. I contacted Tom Schoonover to inform him about the broken belt and leaking valve. I told him to remove the oil residue from inside the dike. |
1460825076 | 2005-06-28 | Salt Water Injection Well | No Violations | Witnessed packer and tubing installation. |
1468954694 | 2016-07-18 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 Follow up inspection. JD Drilling Service rig is on site with the mast up. No attempt has been made to release the packer and pull the tubing. The injection line is disconnected from the well between the pump and filter housing. Tubing master valve and annulus valve are closed. Containment dike has 6 inches of water in it. |
1474631235 | 2016-09-21 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 follow up inspection. Service rig ran 2 3/8 inch tubing with an overshot tool. The parted casing was retrieved at 732 feet. The tubing and packer became stuck in the wellhead collar. Rig crew is currently working on retrieving the packer from the well casing. |
1478184571 | 2016-10-31 | Salt Water Injection Well | No Violations | Compliance Notice #43712172 Follow up inspection. Installed a rebuilt Haliburton R-4 packer (3 shear pins installed) with new 2 3/8 tubing to 2976 Set packer and filled annulus with fresh water and inhibitor. The water level would drop at a constant rate. Additional tension was pulled three times. After the last attempt to pull tension the shear pins released the packer. |
1478264367 | 2016-11-04 | Administrative Inspection | No Violations | Received a phone call at 7:50 am from Jonathan Reese. Jonathan stated that they have decided to pull the tubing and packer out of the well. They are going to do a cement squeeze on the 5 inch casing. I told him to send their plans to the UIC Section for approval. |
1481897674 | 2016-12-13 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 follow up inspection. JD Drilling service rig is on the well. The well is shut in. No one on site during the inspection. |
1482055562 | 2017-02-03 | Salt Water Injection Well | No Violations | Installed a rebuilt Haliburton R-4 packer (3 shear pins installed) with new 2 3/8 tubing to 2698.9 Set packer and filled annulus with fresh water and inhibitor. The water level would drop at a constant rate. Additional tension was pulled twice. After the second time a joint was pulled out and packer was set. The water level still dropped at a consistent rate and as such was not able to fill the annulus with fluid to test. I witnessed two more joints of pipe with additional attempts to fill with water to no avail. |
1483914529 | 2016-08-30 | Administrative Inspection | No Violations | Received a phone call from Jonathan Reese. Jonathan informed me that the tubing parted at 282 feet while attempting to release the packer. Additionally a section of the wellhead slip fell into the 5.5 inch casing. They are scheduling tools to fish out the slip. They plan to use an overshot to retrieve the tubing and packer. |
1490983468 | 2017-03-30 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 Follow up Inspection. Witnessed a rebuilt Halliburton R-4 packer and used string of 2 3/8 inch tubing being installed in the 5 1/2 inch casing. The packer was set at 2391 feet. The packer has 4 shear pins installed and was set with 27,000 lbs. tension. The annulus was filled with 45.19 barrels fresh water and 1 gallon inhibitor. The annulus was tested at 895 psi for 15 minutes with no loss in pressure. The packer variance is under review by the UIC Section. |
1491507202 | 2017-04-06 | Surface Facility Construction | No Violations | The concrete containment dike has sections that were cut out or damaged during the recent workover. I talked to Jonathan Reese and they plan to pour concrete as soon as possible. The injection tubing is shut in and disconnected from the injection line. |
1525353102 | 2018-04-30 | Surface Facility Construction | No Violations | Meet on location with Jim Diddle and Spence Carpenter. We discussed their plans to up grade the surface facility to include a new containment dike, tanks, unloading pads and access road. They are going to submit plans to the UIC section for approval. |
1542657011 | 2018-11-14 | Surface Facility Construction | No Violations | On site meeting with JD Drilling and UIC Section Supervisor and UIC Section Geologist. Reviewed facility modification plans. |
1553091908 | 2019-03-07 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted. The containment dike has ice in the low portion of the dike near the sump. |
1559735526 | 2003-03-05 | Salt Water Injection Well | No Violations | No violations at this time. |
1560451044 | 2019-6-13 0:00: | SW | No Violations | 2.50 |
1565375648 | 2019-8-5 0:00:0 | SW | No Violations | 3.00 |
1578070120 | 2020-1-2 0:00:0 | SW | No Violations | 1.00 |
1584715905 | 2020-3-17 0:00: | SW | No Violations | 0.80 |
1587134013 | 2020-4-9 0:00:0 | SW | No Violations | 2.50 |
1610057809 | 2019-04-03 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification posted. The containment dike is free of fluids. |
1668589668 | 2007-06-04 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1676448743 | 2013-06-06 | Salt Water Injection Well | No Violations | No violations. |
1689091629 | 2005-07-13 | Salt Water Injection Well | No Violations | Acid job and mechanical integrity test on the well. |
1694538291 | 2016-04-13 | Salt Water Injection Well | No Violations | Compliance notice # 437121172 Follow up. Meet with Tom Schoonover on site. Reviewed plans and procedures for the well. The injection line is disconnected from the injection tubing. |
1712217540 | 2018-12-06 | Salt Water Injection Well | No Violations | Compliance Notice # 1177424647 follow up inspection. Tom Schoonover responded to the location and replaced the 2 inch valve and pumped out the dike fluids into the tank. |
1714944459 | 2020-7-10 0:00: | SW | No Violations | 2.00 |
1742995665 | 2016-09-19 | Salt Water Injection Well | No Violations | Compliance Notice # 43712172 Follow up inspection. The wellhead slip has been recovered from the 5.5 inch casing. The well is shut in with a 5.5 inch by 2 inch swedge with a closed 2 inch valve. Currently scheduling an over shot tool to retrieve the injection tubing. |
1751102729 | 2013-10-28 | Salt Water Injection Well | No Violations | Inspected containment dike, tanks, annulus pressure, injection pressure and injection pump. Dike is free of water. Identification is on tank. |
1778196079 | 2012-09-07 | Salt Water Injection Well | No Violations | The fluids have not been removed from the dike. The cracks have not been fixed yet. |
1781090956 | 2011-10-24 | Salt Water Injection Well | No Violations | No violations observed during inspection. |
1788570732 | 2017-02-07 | Salt Water Injection Well | No Violations | I arrived at location. Jonathon Reese explained that they pulled 6 additional joints out of the hole on Monday and finally got the well to hold fluid and test. I was given a tally sheet of the pipe and a rendered drawing explaining the cement and pipe in the hole. I tested the well which was holding fluid now at 885 psi. I started the timer and the well held steady at 885 psi the entire 15 minutes elapsed time. I then shut the valves and unhooked my gauge. |
1828429915 | 2004-10-08 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1840395099 | 2015-03-12 | Salt Water Injection Well | No Violations | No noted violations. Pump running during inspection. |
188519530 | 2016-3-16 0:00: | SW | No Violations | |
1887350970 | 2017-02-28 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017. Fees and fee reports received 7/3/2017 |
1914509543 | 2004-02-05 | Salt Water Injection Well | No Violations | Well pressures were measured, while the pump was on. No violations at the time of inspection. |
1922888056 | 2019-10-8 0:00: | SW | No Violations | 2.00 |
1931411044 | 2018-07-26 | Salt Water Injection Well | No Violations | Inspected the containment dike, tanks, injection pump, injection line, injection pressure and annulus pressure. Identification is posted on an 100 barrel steel tank. The containment dike is free of fluids except in the deep area of the dike by the sump pit which has 4 inches of fluid around the sump. The sump pump is not plugged into the electric cord. |
1931432038 | 2010-11-24 | Salt Water Injection Well | No Violations | Top joint of injection tubing is rusted and flaking pieces of steel into the dike. No leaks observed on the injection line. Brine pump is leaking some brine into dike from bad seal. I have talked to Reese about the issues. |
1956295532 | 2003-08-14 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1976532510 | 2007-10-22 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1995319957 | 2004-08-17 | Salt Water Injection Well | No Violations | No violations. |
2020914655 | 2016-04-08 | Salt Water Injection Well | No Violations | Meet Jonathan Reese on site to review well records and logs. Service rig is on the well. |
2022624148 | 2017-03-23 | Salt Water Injection Well | No Violations | Compliance Notice # 437121172 follow up inspection. JD Drilling service rig and crew on site to pull tubing and packer, tally the tubing then run tubing and packer in to the well. The packer shear pins were sheared while attempting to release the packer. The tubing and packer were pulled from the casing. The R-4 packer had the shear pins replaced and the packer and tubing were ran back into the production casing. The packer was unable to set. The tubing and packer are being removed from the well. The packer job will be rescheduled. |
2026069320 | 2009-06-08 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
2060913777 | 2014-10-07 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2010, 2011, 2012, and 2013. The Disposal Fee Report for the 3rd and 4th Quarter of 2013 needs to be filed also. |
2066280206 | 2006-12-18 | Salt Water Injection Well | No Violations | Pump was on, while pressures were measured. No violations were found. |
2089076504 | 2008-06-02 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
2098154912 | 2016-11-03 | Salt Water Injection Well | No Violations | Compliance Notice #43712172 Follow up inspection. Installed a rebuilt Haliburton R-4 packer (4 shear pins installed) with new 2 3/8 tubing to 2981 Set packer and filled annulus with fresh water and inhibitor. Annulus fluid level would not stabilize. Bubbles were observed at the surface in the fluid. After multiple attempts to set and release the packer and apply additional tension to the packer, the decision was made to not try and test the annulus. The well was shut in with a master valve closed on the injection tubing and the wellhead tightened (all valves shut). |
2124639136 | 2004-07-20 | Salt Water Injection Well | No Violations | New valves were installed. Well is in compliance. |
2135889161 | 2004-03-09 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
2137526162 | 2011-08-05 | Salt Water Injection Well | No Violations | No violations observed during inspection. |
2140548443 | 2005-01-13 | Salt Water Injection Well | No Violations | The old tanks (three 210 bbl) were removed from the dike and replaced with two 100 bbl tanks. |
225544723 | 2007-9-10 0:00: | SW | No Violations | |
228473619 | 2017-2-23 0:00: | SW | No Violations | 0.50 |
292008693 | 2017-1-17 0:00: | SW | No Violations | 1.50 |
339358181 | 2005-6-29 0:00: | SW | No Violations | |
378612605 | 2007-4-12 0:00: | SW | No Violations | |
429911517 | 2009-5-7 0:00:0 | SW | No Violations | |
437121172 | 2016-3-22 0:00: | SW | No Violations | 2.00 |
460588448 | 2016-8-31 0:00: | SW | No Violations | 2.00 |
482761561 | 2005-6-16 0:00: | SW | No Violations | |
500521118 | 2009-8-18 0:00: | SW | No Violations | |
516505157 | 2016-9-9 0:00:0 | SW | No Violations | 3.50 |
585581282 | 2012-9-12 0:00: | SW | No Violations | 0.30 |
630792659 | 2003-12-4 0:00: | SW | No Violations | |
651281734 | 2016-8-24 0:00: | SW | No Violations | 6.00 |
691691163 | 2005-7-7 0:00:0 | SW | No Violations | |
705879725 | 2005-10-26 0:00 | SW | No Violations | |
720595477 | 2019-12-11 0:00 | SW | No Violations | 2.00 |
741923698 | 2019-4-29 0:00: | SW | No Violations | |
757362892 | 2018-9-18 0:00: | SW | No Violations | 0.50 |
758544633 | 2018-11-7 0:00: | SC | No Violations | 3.50 |
779827391 | 2017-2-6 0:00:0 | SW | No Violations | 0.40 |
812551808 | 2006-11-6 0:00: | SW | No Violations | |
85239448 | 2003-5-20 0:00: | SW | No Violations | |
867109566 | 2006-3-29 0:00: | SW | No Violations | |
898098164 | 2018-3-14 0:00: | SW | No Violations | 0.30 |
942925581 | 2003-5-20 0:00: | SW | No Violations | |
975640246 | 2006-10-18 0:00 | SW | No Violations | |
991091813 | 2014-10-27 0:00 | SW | No Violations | |
991614811 | 2015-6-9 0:00:0 | SW | No Violations | 1.00 |
PL10998 | PL | No Violations | ||
UIC109 | 1987-2-2 0:00:0 | SW | No Violations | |
UIC120 | 1987-3-9 0:00:0 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0015862736 | US-OH-115514 | 2014-10-31 | Failure to file salt water injection annual report | |
0034519132 | US-OH-123624 | 2004-05-11 | Violation of injection tubing/fitting requirements | |
0188519530 | US-OH-118936 | 2017-07-13 | 9-3-04B | Failure to file salt water injection annual report |
0287124112 | US-OH-122978 | 2018-08-03 | NONE | Failure to report disposal fees |
0437121172 | US-OH-124704 | 2017-04-03 | 9-3-07(H) | Mechanical failure/contamination |
0491779347 | US-OH-125384 | 2006-07-19 | Failure to keep dike or pit free of brine or other wastes | |
0591792814 | US-OH-126660 | 2011-03-11 | Mechanical failure/contamination | |
0671326736 | US-OH-127595 | 2015-09-01 | Pits not liquid tight/Improper construction or use | |
0741923698 | US-OH-128444 | 2019-05-09 | Failure to file salt water injection annual report | |
0942925581 | US-OH-130784 | 2003-06-26 | Tanks not liquid tight/Improper burial | |
1050959132 | US-OH-100846 | 2012-05-17 | Failure to keep dike or pit free of brine or other wastes | |
1056651171 | US-OH-101047 | 2003-06-26 | Tanks not liquid tight/Improper burial | |
1075496536 | US-OH-101597 | 2003-06-26 | No SPCC dike/or failure to keep dike free of water or oil | |
1075496536 | US-OH-101598 | 2003-06-26 | Violation of injection tubing/fitting requirements | |
1075496536 | US-OH-101599 | 2003-06-26 | Tanks not liquid tight/Improper burial | |
1112700367 | US-OH-102820 | 2017-07-13 | 9-3-04B | Failure to file salt water injection annual report |
1140947552 | US-OH-103572 | 2005-05-16 | Failure to perform Mechanical Integrity Test | |
1177424647 | US-OH-104713 | 2018-12-19 | 9-3-05(A)6 | Contamination at surface facility (permit after 6-1-82) |
1177424647 | US-OH-104714 | 2018-12-19 | 9-3-08(B) | Tanks not liquid tight/Improper burial |
1310959146 | US-OH-108801 | 2018-08-03 | Failure to file salt water injection annual report | |
1345581844 | US-OH-110014 | 2012-09-20 | Contamination at surface facility (permit after 6-1-82) | |
2060913777 | US-OH-120997 | 2014-10-31 | Failure to file salt water injection annual report |
For data sources see[5]