Well Details

Well ID: 34-105-23651
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: FQ ENERGY SERVICES LLC
Well Pad ID:
Farm/Lease Name: MCKELVEY (SWIW #23)
License Status: Active Injection
License Date: 2018-08-08
Spud Date: 2009-01-24
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2009-02-10
Well Total Depth: 9082.00 ft
Configuration: Vertical
Latitude: 38.960000
Longitude: -81.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-01-23 Proposed Formations:CLINTON-ROSE RUN (MAY NOT PRODUCE BEREA, OHIO SHALE, NEWBURG OR LOCKPORT{WILLIAMSPORT}), Issued Date:1/23/2009, Expired Date:1/23/2010 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2009-02-10 WCR 07-16-2015
Plugged Back 2009-02-11 WCR 07-16-2015
Completion Report Received 2010-11-24 WCR 07-16-2015
APP 2014-09-02 Proposed Formations:CLINTON, Issued Date:9/2/2014, Expired Date:9/1/2016 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW
Last Compliance Report 2014-09-02 WCR 07-16-2015
Change of Owner 2018-04-16 Operator changed from 516, MURPHY OIL COMPANY INC to 9679, FQ ENERGY SERVICES LLC
APP 2018-08-08 Proposed Formations:CLINTON AND MEDINA SANDSTONES, Issued Date:8/8/2018, Expired Date:8/7/2020 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW
Record Last Modified 2018-10-26 WCR 07-16-2015
Construction Permit Expires 2020-08-07 WCR 07-16-2015

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-01-13 5532 5591 81
5532 5591 81
5532 5591 81

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2000 Bbl 40000
2015-12-30 ACID 0 2000 Gal 0 Producers Service Corporation

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 MURPHY OIL COMPANY INC 457.00 0.00 90
2010 MURPHY OIL COMPANY INC 8591.00 0.00 90
2011 MURPHY OIL COMPANY INC 8421.00 0.00 365
2012 MURPHY OIL COMPANY INC 5889.00 0.00 366
2013 MURPHY OIL COMPANY INC 4311.00 0.00 365
2014 MURPHY OIL COMPANY INC 2024.00 0.00 365
2015 MURPHY OIL COMPANY INC 0.00 0.00 0
2016 MURPHY OIL COMPANY INC 0.00 0.00 0
2017 MURPHY OIL COMPANY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 MURPHY OIL COMPANY INC Brine 0 90
2010 MURPHY OIL COMPANY INC Brine 4 90
2011 MURPHY OIL COMPANY INC Brine 0 365
2012 MURPHY OIL COMPANY INC Brine 0 366
2013 MURPHY OIL COMPANY INC Brine 0 365
2014 MURPHY OIL COMPANY INC Brine 0 365
2015 MURPHY OIL COMPANY INC Brine 0 0
2016 MURPHY OIL COMPANY INC Brine 0 0
2017 MURPHY OIL COMPANY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1032095434 2019-12-9 0:00: SW No Violations 0.50
-10571373 2014-9-2 0:00:0 SW No Violations 3.00
-1075444207 2009-2-11 0:00: PB No Violations
-1217797177 2017-4-3 0:00:0 SW No Violations 2.00
-1229783941 2020-2-19 0:00: SW No Violations 0.50
-124815767 2017-11-16 0:00 SW No Violations 1.00
-1313037999 2016-10-18 0:00 SW No Violations 5.50
-1316300541 2015-2-23 0:00: PW No Violations 1.00
-1382854352 2014-4-16 0:00: PW No Violations 1.00
-1394495525 2017-2-21 0:00: SW No Violations 2.50
-1405499637 2020-7-23 0:00: SW No Violations 0.50
-1440917474 2016-3-2 0:00:0 SW No Violations
-1522139763 2018-8-22 0:00: SW No Violations 2.10
-161007323 2020-4-6 0:00:0 SW No Violations 0.50
-1618916537 2019-2-7 0:00:0 SW No Violations 0.50
-1648842289 2017-12-12 0:00 SW No Violations 0.20
-1663701807 2014-6-9 0:00:0 PW No Violations 5.50
-1700101207 2020-6-15 0:00: SW No Violations 1.00
-1738476069 2016-5-23 0:00: SW No Violations 1.00
-1844928860 2019-1-7 0:00:0 SW No Violations 0.70
-1916730622 2018-5-3 0:00:0 SW No Violations 0.50
-2057437953 2015-6-25 0:00: SW No Violations 0.50
-221323790 2018-8-31 0:00: SW No Violations 0.80
-272877354 2017-8-29 0:00: SW No Violations 0.70
-411383472 2019-12-24 0:00 SW No Violations 0.50
-423801508 2009-2-17 0:00: DD No Violations
-465261719 2016-12-14 0:00 SW No Violations 0.50
-67988880 2018-3-1 0:00:0 SW No Violations
-716304293 2016-10-21 0:00 SW No Violations 5.00
-753335034 2019-11-7 0:00: SW No Violations 0.80
-822174325 2019-6-5 0:00:0 SW No Violations 0.50
-986178809 2009-2-11 0:00: PB No Violations
0010571373 2014-09-02 Salt Water Injection Well No Violations Conversion to salt water injection well. Mechanical integrity test. Tested annulus at 1325 psi for 15 minutes with no loss in pressure. Well is not connected to injection line or equipment. Annulus pressure was lowered after the test to 500 psi.
0045935361 2018-10-31 Salt Water Injection Well No Violations Inspected the Harris facility, Injection pressure and annulus pressure. The annulus pressure was zero. Wes Harmon was on site and determined that the wellhead slip ring was loose. After tightening the ring a Mechanical Integrity test on the annulus was done. Tested at 1500 psi at 5 minutes 1500 psi, at 15 minutes 1500 psi. Sampled brine from the Mills brine transfer pump and tested with the state issued Hydrometer. SG 1.17. The pressure on the brine transfer line from the Mills to Harris facility is 10 psi.
0055010765 2016-07-07 Salt Water Injection Well No Violations Inspected the Harris facility, injection pressure and annulus pressure. Identification posted.
0067988880 2018-03-01 Salt Water Injection Well Violations Noted The Division received annual report form 204. Review of the form 204 revealed an exceedance of the maximum allowable injection pressure. The injection pressure shall be reduced and the auto shut down switch shall be adjusted to the maximum allowable injection pressure. A follow-up inspection will be conducted.
0124815767 2017-11-16 Salt Water Injection Well No Violations My inspection reveled the salt water injection well had 1249 psi on the injection tubing and 678 psi on the annulus. The well has a legible identification. No violations were noted.
0184102191 2017-01-17 Salt Water Injection Well No Violations Inspected the Harris surface facility, injection pump, injection pressure and annulus pressure. Identification posted.
0221323790 2018-08-31 Salt Water Injection Well No Violations Status check of the well. The injection line valve is open and the injection tubing master valve is open. I contacted Wes Harmon and told him that the permit conditions have not been completed and they do not have authorization to inject at this time. I told him to shut in the well.
0229111933 2018-09-28 Salt Water Injection Well No Violations Chiefs Order 2018-257. Witnessed opening of the injection line valve and injection tubing master valve. The Murphy pressure cut off switch at the Harris facility is set at 1275 psi. Inspected the brine transfer pipeline pressure from the Mills Facility to the Harris facility. The pipeline pressure is 290 psi.
0272877354 2017-08-29 Salt Water Injection Well No Violations My inspection today revealed the saltwater injection well had 320 psi on the annulus and 310 psi on the tubing. Legible identification was posted.
0279134404 2015-07-27 Salt Water Injection Well No Violations Injection operation authorization Chiefs Order 2015-359. Inspected the injection pressure, annulus pressure and the Harris surface facility 34-105-23637. Well is connected to injection line with valves open. Currently not injecting due to lack of brine at the facility. Met with Wes Harmon on site.
0361471089 2018-08-22 Salt Water Injection Well No Violations Producers service corporation on site for acid job.
0400649068 2018-04-30 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted.
0423801508 2009-02-17 Drill / Deepen / Reopen No Violations Drilling completed. The rig was still onsite.
0465261719 2016-12-14 Salt Water Injection Well No Violations Inspected the Harris Facility (34-105-23637), Injection pressure and annulus pressure. Identification posted.
0484910677 2014-12-02 Preliminary Restoration No Violations Preliminary Restorations requirements met.
0716304293 2016-10-21 Salt Water Injection Well No Violations Witnessed the service rig release the tubing from the Baker packer with the on-off tool. Circulated fresh water and inhibitor back to surface with pump truck. All fluids were circulated into a Fountain Quail vac truck. Attach the tubing to the packer and test the annulus at 1385 psi for 15 minutes with no loss in pressure. Test the injection tubing then pressure up and pump out the pressure plug.
0851949903 2019-03-05 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification is posted. Annulus is frozen. Collected a brine sample at the mills transfer facility and measured the specific gravity with the state issued hydrometer. Specific gravity was 1.16.
0878595023 2015-12-30 Salt Water Injection Well No Violations Producers Service Company on site for a acid treatment. Received copy of the report from Wes Harmon. Checked the injection pressure and annulus pressure after the well has put back in line for injection.
0972033105 2013-06-13 Production Wells No Violations No violations.
0986178809 2009-02-11 Plug / Plug Back No Violations Witnessed plug-back with Steve Ochs.
1008807892 2015-06-17 Surface Facility Construction No Violations 4Injection line from the Harris facility # 3637 has been installed. The line has not been connected to the injection tubing.
1026446972 2018-03-05 Salt Water Injection Well No Violations The salt water injection well was written up for 1501: 9-3-07 (D) exceeding maximum allowable injection pressure. The injection tubing had 255 psi and the annulus had 9 psi. The containment dike was free of fluids. This satisfies the compliance notice issued on 3.1.2018.
1061403422 2019-7-18 0:00: SW No Violations 0.50
1061921515 2018-02-06 Salt Water Injection Well No Violations I completed a visual inspection of this well. The visual inspection of the well revealed all fittings were tight and not leaking. Identification was posted at the well.
1075444207 2009-02-11 Plug / Plug Back No Violations Witnessed the plug back job. All conditions were acceptable.
1129836470 2018-12-11 Salt Water Injection Well No Violations Inspected the Harris facility, injection pressure and annulus pressure. Identification is posted. A sample of the brine was collected at the Mills Transfer to Harris pump house. The sample was tested with the State issued Hydrometer. The results were SG 1.17.
1157338578 2009-01-27 Drill / Deepen / Reopen No Violations Witnessed the installation and cementing of surface casing. All conditions were acceptable.
1217797177 2017-04-03 Salt Water Injection Well No Violations Inspected the Harris Facility 34-105-23637, Injection pressure and annulus pressure. Identification posted at the well.
1240947671 2009-04-27 Preliminary Restoration No Violations
1313037999 2016-10-18 Salt Water Injection Well No Violations Service rig is on the well. Used power tongs to release the packer. Removed one joint of tubing and reset the packer at 5487 feet. Attempted to test the annulus. Was unable to pressure up past 60 psi. Packer was released and company decided to trip the tubing and packer out of the well.
1316300541 2015-02-23 Production Wells No Violations Conversion to SWIW status check. Injection line has not been installed to the well. The injection tubing is not connected to any injection equipment. Tubing does have a master valve installed. Annulus valve frozen shut.
1382854352 2014-04-16 Production Wells No Violations Asked to locate well and discuss history and construction.
1394495525 2017-02-21 Salt Water Injection Well No Violations Inspected the Harris SWIW facility 34-105-23637, Injection pressure and annulus pressure. Identification posted.
1402317169 2014-06-06 Salt Water Injection Well No Violations On site to witness service rig run new Baker Set Lock Packer and new 2.875 tubing in hole and set Packer at 5520 and owner will pressure test annulus of tubing next week.
1402514354 2014-06-09 Production Wells No Violations Request for inspection from Andrew Adgate ODNR DOGRM UIC Geologist. Site evaluation for salt water injection well (SWIW) permit. GPS locations of access road, tank and well. Searched for fresh water wells with-in 1/2 mile of the proposed salt water injection well. ODNR Water Well Log Search revealed two water wells with-in 1/2 mile of the site. Water well # 904878 N38.963220 W081.79242 and # 517801 N38.972822 W081.784806. Field inspection revealed an additional water well South East of the wellhead at N38.96319 W081.78295. Well is located 97 feet West of Route 124. Well is located 600 feet South of an unnamed stream that flows into the Ohio River. Well is located 922 feet West of the Ohio River.
1412605268 2014-10-06 Salt Water Injection Well No Violations Well is equipped with packer and tubing. Well is not connected to injection equipment or injection line. Master valve on tubing is closed. Checked annulus pressure.
1417725829 2014-12-04 Salt Water Injection Well No Violations This well is not connected to an injection line or injection equipment. I talked to Wes Harmon about the need to have a current identification on this well. The annulus gauge had froze and busted allowing the annulus pressure to fall off. I told Wes that they will need to test the annulus prior to start up of injection operations.
1440917474 2016-03-02 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 3rd, & 4th quarter of 2015. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED
1441287949 2015-09-01 Salt Water Injection Well No Violations Inspected the Harris SWIW facility API# 3410523637 (Brine is transferred by injection line from the Harris facility to the McKelvey 3 ). Inspected the tanks, containment dike, injection pump, injection pressure and annulus pressure.
1448457194 2015-11-24 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. Inspected the Harris Facility 3410523637 containment dike and tanks.
1450329532 2019-5-9 0:00:0 SW No Violations 0.50
1476970640 2016-10-17 Salt Water Injection Well No Violations Service rig set up on well. Pulled 8,000 lbs. above string weight. Attempted to release packer. The packer was not released. Power tongs have been scheduled for 10-18-16.
1477574053 2016-10-20 Salt Water Injection Well No Violations Witnessed installation of 5454 feet of 2 7/8 inch tubing with a rebuilt Baker Loc Set Packer with on-off tool and pressure plug. Packer was set on compression.
1521843857 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION ON FEBRUARY 26, 2018
1522139763 2018-08-22 Salt Water Injection Well No Violations Witnessed a test of the injection line from the injection line valve at ground level (at the well site) to the injection tubing master valve. The line was tested at 1670 psi for 15 minutes with 2 leaks observed on fittings. The leaks were fixed and the line was retested at 1670 psi for 15 minutes with no loss in pressure. Witnessed injection operations and the initial injection through the tubing.
1525696677 2018-05-03 Salt Water Injection Well No Violations Request for inspection from Dominique Haneberg-Diggs ODNR DOGRM UIC Geologist. Site evaluation for salt water injection well (SWIW) permit. Well GPS N38.96465 / W081.78578. Searched for fresh water wells with-in 1/2 mile of the proposed salt water injection well. ODNR Water Well Log Search revealed two water wells with-in 1/2 mile of the site. Water well # 904878 N38.963220 W081.79242 and # 517801 N38.972822 W081.784806. Field inspection revealed an additional water well South East of the wellhead at N38.96319 W081.78295. Well is located 97 feet West of Route 124. Well is located 600 feet South of an unnamed stream that flows into the Ohio River. Well is located 922 feet West of the Ohio River.
1535034416 2018-08-21 Salt Water Injection Well No Violations Witnessed Baker Hughes wire line run a cased hole log and perforate (tubing-conveyed perforating through existing 2-7/8 inch tubing) for new injection interval, Per convert to SWIW permit dated 8-8-2018. Perforations are from 5658 feet to 5668 feet with two shots per foot. And 5645 feet to 5655 feet with two shots per foot. ODNR DOGRM UIC Geologist was on site for the first set of perforations.
1536602089 2018-09-10 Surface Facility Construction No Violations Convert to SWIW permit 8-8-2018. Constructional condition 3. Tested Annulus at 1480 psi, at 5 minutes 1480 psi, at 15 minutes 1480 psi. Tested the injection line from the Harris surface facility to the McKelvey 3. Test line at 1490 psi, at 5 minutes 1485 psi, at 15 minutes 1475 psi. Tested the pipeline from the Mills Facility to the Harris Facility at 1050 psi, at 5 minutes 1035 psi, at 15 minutes 1025 psi.
1618916537 2019-02-07 Salt Water Injection Well No Violations Inspected the Harris surface facility, The injection pressure and annulus pressure. Identification is posted.
1648842289 2017-12-12 Salt Water Injection Well No Violations My inspection revealed the salt water injection well had 310 psi on the annulus and 400 psi on the injection tubing. The well had a legible identification posted.
1652960386 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED
1663701807 2014-06-09 Production Wells No Violations Witnessed 50 barrels of fresh water and inhibitor being circulated through tubing to surface. Sting tubing back on packer. Annulus was tested by company gauge to 1380 psi. The packer was equipped with a pump out plug. The plug was released by pumping through the tubing. Worked on the site evaluation for the permit to convert to salt water injection well. GPS the well, access road, tank battery and production wells that are on the location.
1735590238 2012-08-29 Production Wells No Violations No violations.
1738476069 2016-05-23 Salt Water Injection Well No Violations Inspected the injection pressure and the annulus pressure. Identification posted.
184102191 2017-1-17 0:00: SW No Violations 1.00
1844928860 2019-01-07 Salt Water Injection Well No Violations Inspected the Harris surface facility, injection pressure and annulus pressure. Identification is posted.
1916730622 2018-05-03 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted. Accompanied by UIC Geologist.
1963392303 2015-10-21 Salt Water Injection Well No Violations Inspected the Harris Facility API# 34-105-23637, Inspected the injection pressure and annulus pressure.
1974355781 2015-06-25 Salt Water Injection Well No Violations Administered line test from pump to McKelvey tank at Harris injection facility. Since line will not experience injection pressures maximum injection pressure testing was not deemed necessary for testing purposes. 10 psi was held on the line for 15 minutes with no loss in pressure, witnessed company bleeding down line. I also witnessed company open line and bleed down pressure from the main line from the facility to the well.
2017068309 2019-6-10 0:00: SW No Violations 0.50
2026043563 2019-04-04 Salt Water Injection Well No Violations Inspected the injection pressure and annulus pressure. Identification posted.
2054576374 2017-03-10 Salt Water Injection Well No Violations Inspected the Harris Facility 34-105-23637, Injection pressure and annulus pressure. Identification is posted.
2057437953 2015-06-25 Salt Water Injection Well No Violations Witnessed line test for the McKelvey well from the well head to the injection facility. 1320 psi was placed on the line from the facility to the well head. Test was administered at the well head and the line lost no pressure over the 15 minute testing period. Pressures were verified at the facility with the companies gauge as well. After the test the line was closed and the frac valve was opened to bleed the pressure off the well head.
2135021129 2016-10-12 Administrative Inspection No Violations At 11:38 am on 10-12-2016 Received a phone call from Wes Harmon (Fountain Quail) Wes stated that the McKelvey 3 has a mechanical issue and they have scheduled a service rig for 10-13-2016.
229111933 2018-9-28 0:00: SW No Violations 1.40
279134404 2015-7-27 0:00: SW No Violations 1.50
361471089 2018-8-22 0:00: SW No Violations 4.00
372267107 2019-5-22 0:00: SW No Violations 1.00
400649068 2018-4-30 0:00: SW No Violations 0.50
45935361 2018-10-31 0:00 SW No Violations 3.00
484910677 2014-12-2 0:00: PL No Violations 0.70
55010765 2016-7-7 0:00:0 SW No Violations 1.00
735799901 2019-6-24 0:00: SW No Violations 0.70
832487955 2019-10-30 0:00 SW No Violations 0.70
851949903 2019-3-5 0:00:0 SW No Violations 1.00
878595023 2015-12-30 0:00 SW No Violations 3.00
972033105 2013-6-13 0:00: PW No Violations 0.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0067988880 US-OH-127691 2018-03-27 9-3-07(D) Exceeding maximum allowable injection pressure
1521843857 US-OH-114480 2018-03-27 NONE Failure to report disposal fees
1652960386 US-OH-116310 2016-04-04 Failure to file salt water injection annual report

For data sources see[9]