Well Details

Well ID: 34-105-23660
Loading map...
Country: United States
State: Ohio
County: Meigs
Municipality: Chester Township
Operator Name: RAINBOW OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: PARKER GEORGE
License Status: Producing
License Date: 2009-07-29
Spud Date: 2009-08-27
Spud Drilling Contractor: RAINBOW DRLG
Final Drill Date: 2009-10-13
Well Total Depth: 1820.00 ft
Configuration: Vertical
Latitude: 39.110000
Longitude: -81.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-29 Proposed Formations:BEREA, Issued Date:7/29/2009, Expired Date:7/29/2010 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-10-13
Completion Report Received 2010-03-03
Construction Permit Expires 2010-07-29
Last Compliance Report 2015-04-02
Revocation 2015-04-02
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-05-24 1652 1678 30
2010-05-24 1736 1742 10
1652 1678 30
1736 1742 10
1652 1678 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 10 1400 Bbl 14000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 RAINBOW OIL & GAS LLC 2836.00 250.00 365
2011 RAINBOW OIL & GAS LLC 1500.00 300.00 365
2012 RAINBOW OIL & GAS LLC 1209.00 225.00 366
2013 RAINBOW OIL & GAS LLC 1551.00 271.00 365
2014 RAINBOW OIL & GAS LLC 2149.00 162.00 365
2015 RAINBOW OIL & GAS LLC 190.00 45.00 185
2016 RAINBOW OIL & GAS LLC 525.00 61.00 90
2017 RAINBOW OIL & GAS LLC 825.00 138.00 90
2018 RAINBOW OIL & GAS LLC 1185.00 167.00 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 RAINBOW OIL & GAS LLC Brine 250 365
2011 RAINBOW OIL & GAS LLC Brine 360 365
2012 RAINBOW OIL & GAS LLC Brine 311 366
2013 RAINBOW OIL & GAS LLC Brine 2051 365
2014 RAINBOW OIL & GAS LLC Brine 259 365
2015 RAINBOW OIL & GAS LLC Brine 43 185
2016 RAINBOW OIL & GAS LLC Brine 120 90
2017 RAINBOW OIL & GAS LLC Brine 146 90
2018 RAINBOW OIL & GAS LLC Brine 151 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1209112638 2014-1-6 0:00:0 AD No Violations 1.00
-1755793641 2009-11-6 0:00: DD No Violations
-1985234387 2013-2-19 0:00: PW No Violations 0.80
-776914709 2013-6-6 0:00:0 AD No Violations 1.00
-967673684 2010-3-17 0:00: PL No Violations
0776914709 2013-06-06 Annular Disposal No Violations Follow up to 1268918488. No violations at time of inspection. Well is plumbed up for Annular disposal. Pumping unit running at time of inspection.
0967673684 2010-03-17 Preliminary Restoration No Violations FOLLOW UP TO NOV # 1268918488 Pits are open and full of oil and fluids. A steel 210 bbl tank is on location and connected to production equipment and to the well. A 1 1/2 black plastic line is connected to the tank drain and has been ran to the pit. Well is equipped and capable of gas production. Well is equipped with a pump jack, rods, tubing, electric motor and electric service. Electric service line is ran on top of the ground from the pole to the well. Some welding has been done to the wellhead. A test rig on the annulus with a gauge and a quick connect suggests testing for AD. Inspector has not been notified of a AD test. No Identification on well or tank. Spud date 8-27-2009. 1509.072 (A) Within 5 months pits are to be filled in. Fluids in pit must be disposed of in an injection well. Well needs Identification Per 1501:9-9-05(A)(10) All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank, as to owner, lease name, well number, permit number, county, and an emergency telephone number. The electric service line is on top of the ground. Bury the line or run line on poles to the well.
1209112638 2014-01-06 Annular Disposal No Violations Checked on well because Columbus had asked me to check on Annular Disposal status of Parker #1 well on same lease. The water from the Parker #1 was being transfer from well #1 to the tanks associated with the Parker #2. Surface casing head visible, water being stored in a 150 Barrel steel tank and disposed of in a liquid tight system. No noted violations at site.
1268918488 2010-03-17 Preliminary Restoration Violations Noted Pits are open and full of oil and fluids. A steel 210 bbl tank is on location and connected to production equipment and to the well. A 1 1/2 black plastic line is connected to the tank drain and has been ran to the pit. Well is equipped and capable of gas production. Well is equipped with a pump jack, rods, tubing, electric motor and electric service. Electric service line is ran on top of the ground from the pole to the well. Some welding has been done to the wellhead. A test rig on the annulus with a gauge and a quick connect suggests testing for AD. Inspector has not been notified of a AD test. No Identification on well or tank. Spud date 8-27-2009. 1509.072 (A) Within 5 months pits are to be filled in. Fluids in pit must be disposed of in an injection well. Well needs Identification Per 1501:9-9-05(A)(10) All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank, as to owner, lease name, well number, permit number, county, and an emergency telephone number. The electric service line is on top of the ground. Bury the line or run line on poles to the well.
1421237739 2015-01-13 Annular Disposal No Violations A mechanical integrity test was attempted by the company to retain their AD status on the Parker #2. Two attempts were made to administer the test but the well was unable to hold the required pressure due to minor leaks in fittings at the surface.
1427141861 2015-03-23 Annular Disposal No Violations Attempted to administer annular disposal test but annulus did not have sufficient pressure. Will return later this afternoon to administer test.
1755793641 2009-11-06 Drill / Deepen / Reopen No Violations Status check to see if ready for AD test. Rig is still on location and operator is preparing to pull rods and tubing out due to sand build up. They will call when ready for AD test.
1926349846 2015-03-23 Annular Disposal No Violations Attempted to administer the 5 year positive differential annular disposal test. Well was unable to hold the required pressure for the hour long testing period.
1985234387 2013-02-19 Production Wells No Violations Well equipped with a pumping unit and an electric motor. The valves on the production casing and the tubing were open. The tank battery consists of a 210 Barrel steel tank plumbed up for annular disposal and a separator. Water was seen running out of the dike drain and was field tested for Chlorides using a Quan-tab test strip. It was found to have less than the EPA drinking water standards for Chlorides levels.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1268918488 US-OH-107220 2013-04-08 Failure to fill pits within 5 mos. (CHANGE) (REPLACE)