{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.79,"lon":-81.26,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Monroe | |
| Municipality: Summit Township | |
| Operator Name: C G O INC | |
| Well Pad ID: | |
| Farm/Lease Name: KUHN WM | |
| License Status: Final Restoration | |
| License Date: 2016-01-29 | |
| Spud Date: 1950-04-24 | |
| Spud Drilling Contractor: | |
| Final Drill Date: 1950-05-05 | |
| Well Total Depth: 788.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.790000 | |
| Longitude: -81.260000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| Original Spud | 1950-04-24 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
| Completed | 1950-05-05 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
| Reached Total Depth | 1950-05-05 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
| Change of Owner | 2015-12-24 | Operator changed from 9998, HISTORIC OWNER to 2849, C G O INC |
| APP | 2016-01-29 | Proposed Formations:SALT SAND, Issued Date:1/29/2016, Expired Date:1/28/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
| Plugged/Abandoned | 2016-02-03 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
| Record Last Modified | 2017-02-10 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
| Construction Permit Expires | 2018-01-28 | STATUS BASED ON REPORT FROM INSPECTOR STOLARIK GMM well was changed to PA status based on plug report |
For data sources see[2]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1993 | C G O INC | 1206.00 | 0.00 | 365 |
| 1994 | C G O INC | 607.00 | 0.00 | 365 |
| 1995 | C G O INC | 977.00 | 0.00 | 365 |
| 1996 | C G O INC | 813.00 | 0.00 | 365 |
| 1997 | C G O INC | 1996.00 | 0.00 | 365 |
| 1998 | C G O INC | 1491.00 | 0.00 | 365 |
| 1999 | C G O INC | 1342.00 | 0.00 | 365 |
| 2000 | C G O INC | 632.00 | 0.00 | 365 |
| 2001 | C G O INC | 601.00 | 0.00 | 365 |
| 2002 | C G O INC | 639.00 | 0.00 | 365 |
| 2003 | C G O INC | 549.00 | 0.00 | 365 |
| 2004 | C G O INC | 518.00 | 0.00 | 365 |
| 2005 | C G O INC | 413.00 | 0.00 | 365 |
| 2006 | C G O INC | 427.00 | 0.00 | 365 |
| 2007 | C G O INC | 470.00 | 0.00 | 365 |
| 2008 | C G O INC | 428.00 | 0.00 | 365 |
| 2009 | C G O INC | 702.00 | 0.00 | 365 |
| 2010 | C G O INC | 534.00 | 0.00 | 365 |
| 2011 | C G O INC | 522.00 | 0.00 | 365 |
| 2012 | C G O INC | 482.00 | 0.00 | 366 |
| 2015 | C G O INC | 67.00 | 0.00 | 270 |
| 2016 | C G O INC | 0.00 | 0.00 | 0 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1993 | C G O INC | Brine | 0 | 365 |
| 1994 | C G O INC | Brine | 9 | 365 |
| 1995 | C G O INC | Brine | 12 | 365 |
| 1996 | C G O INC | Brine | 14 | 365 |
| 1997 | C G O INC | Brine | 19 | 365 |
| 1998 | C G O INC | Brine | 27 | 365 |
| 1999 | C G O INC | Brine | 22 | 365 |
| 2000 | C G O INC | Brine | 15 | 365 |
| 2001 | C G O INC | Brine | 13 | 365 |
| 2002 | C G O INC | Brine | 8 | 365 |
| 2003 | C G O INC | Brine | 6 | 365 |
| 2004 | C G O INC | Brine | 5 | 365 |
| 2005 | C G O INC | Brine | 11 | 365 |
| 2006 | C G O INC | Brine | 8 | 365 |
| 2007 | C G O INC | Brine | 13 | 365 |
| 2008 | C G O INC | Brine | 7 | 365 |
| 2009 | C G O INC | Brine | 11 | 365 |
| 2010 | C G O INC | Brine | 8 | 365 |
| 2011 | C G O INC | Brine | 6 | 365 |
| 2012 | C G O INC | Brine | 10 | 366 |
| 2015 | C G O INC | Brine | 0 | 270 |
| 2016 | C G O INC | Brine | 0 | 0 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -701415840 | 2013-7-15 0:00: | PW | No Violations | 1.50 |
| -743093110 | 2016-9-22 0:00: | FR | No Violations | 1.00 |
| 0701415840 | 2013-07-15 | Production Wells | Violations Noted | Follow up inspection from my last inspection on 12/28/12 as per a request from the landowner Robert Spangler who ask that Ed Crum stop dispersing the production water on the ground surface of his property. On this day I observed that the discharge line leading out on the ground has been cut off but not plugged. And proper well identification needs posted. The well has been registered and production reported since my last visit. The owner Ed Crum shall do as follows- finish removing the while plastic line from the bottom of the 50 barrel production tank and place a plug in the valve according to the ORC. Proper well identification needs posted as well. ODNR Contact- Monroe Co Inspector- Bill Stolarik-1-740-507-6592. |
| 0743093110 | 2016-09-22 | Final Restoration | No Violations | Final restoration status check inspection accompanied on the day by Oil and Gas Inspector Bill Stolarik. Upon inspection it was observed that the well site meets ORC 1509.072. |
| 0848728727 | 2016-06-15 | Final Restoration | No Violations | On this day I met on site with the landowner Dr. Robert Spangler and Boone Ellis with Turner Oil. The landowner is requesting further grading and more vegetation. I informed the landowner that in order for proper vegetation to be established the livestock will need to be removed from the location. |
| 1356719821 | 2012-12-28 | Production Wells | No Violations | Inspection per request of landowner Robert Spangler. Inspection found a well being produced by CGO-Ed Crum that is not registered and has no reported production. Equipment present is 4.5 production casing - 2 tubing and pumping rods with the production valves open and a gas sales meter present with a current sales chart in the meter box. Inspector will follow up with producer and ask Mr. Crum to register the well and enter the complaint in the complaint log database. |
| 1389111568 | 2014-01-07 | Administrative Inspection | No Violations | Administrative inspection to document the follow up of the unresolved violation and CGO not properly registering the said well. On this day I called Bobby Harmon who takes care of the paperwork for Ed Crum and advised Her they still needed to register 2 wells - 34-111-6-3157-0000 & 34-111-2-1043-0000, Bobby said She would complete the registration form 7 and submit it to Ed Crum so He could write the check and sign the paperwork to be submitted to the division. |
| 1445528718 | 2015-10-22 | Production Wells | No Violations | Status check inspection found Harmons well service on location pulling the tubing and pumping rods out of the well. The well has 4.5 set on a formation packer that will need to be recovered from the well. The well shall be plugged in the near future once a plugging permit is received. The owner has also submitted a form 7 transfer to the Division. |
| 1454515883 | 2016-02-03 | Plug / Plug Back | No Violations | 02/02/2016 -Harmons Well Service is rigged up on the hole and has pulled a 4.5 string out of the hole that was set on a formation packer. 2 tubing was ran in the hole to a measured depth of 758. 02/03/2016- Formation cementing was on location and set a 60 sack bottom plug with 1% Gel and 2% calcium additives, the well circulated water to surface 2 barrels into cement displacement. The tubing was pulled up to 417 and 70 sacks of cement was pumped with cement circulated to surface. The remainder of the tubing was pulled out of the hole and the hole was topped off to surface with 16 sacks of cement. Historic records show 163 of 8 casing but upon inspection only the 6.625 casing was visible as present at surface. |
| 1474557261 | 2016-09-22 | Final Restoration | No Violations | Final restoration status check inspection accompanied on the day by Division Staff member Jimmy Wiles. Upon inspection it was observed that the well site meets ORC 1509.072. |
| 848728727 | 2016-6-15 0:00: | FR | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0701415840 | US-OH-127922 | 2013-07-24 | Failure to legibly identify well | |
| 0701415840 | US-OH-127923 | 2013-07-24 | Failure to have required locks, bull plugs |