If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-111-22383 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.74,"lon":-81.27,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Monroe | |
| Municipality: Franklin Township | |
| Operator Name: TRIPLE C OIL & GAS CO | |
| Well Pad ID: | |
| Farm/Lease Name: MALLETT J | |
| License Status: Producing | |
| License Date: 1984-06-21 | |
| Spud Date: 1981-08-05 | |
| Spud Drilling Contractor: | |
| Final Drill Date: 1981-08-11 | |
| Well Total Depth: 2355.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.740000 | |
| Longitude: -81.270000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| CO | 1981-05-06 | 3850 SANDBAR OIL & GAS CO GeoDate 5/6/81 |
| Original Spud | 1981-08-05 | PF=FORM |
| Completed | 1981-08-11 | PF=FORM |
| Reached Total Depth | 1981-08-11 | PF=FORM |
| CO | 1984-06-21 | 3850 SANDBAR OIL & GAS CO GeoDate 6/21/84 |
| Unknown | 1984-06-21 | Issued Date 6/21/84 Expired Date 12/18/84 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
| Construction Permit Expires | 1984-12-18 | PF=FORM |
| Change of Owner | 1998-02-13 | Operator changed from 3850, SANDBAR OIL & GAS CO to 6071, TRIPLE C OIL & GAS CO. |
| Record Last Modified | 2013-10-03 | PF=FORM |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2006-09-11 | 1946 | 1968 | 8 |
| 2006-09-11 | 2082 | 2128 | 9 |
| 1946 | 1968 | 8 | |
| 1946 | 1968 | 8 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| H2O | 0 | 775 Bbl | 30000 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1984 | MUTUAL OIL & GAS CO | 145.00 | 0.00 | 0 |
| 1985 | ATWOOD ENTERPRISES INC | 327.00 | 0.00 | 295 |
| 1993 | SANDBAR OIL & GAS CO | 250.00 | 0.00 | 365 |
| 1994 | SANDBAR OIL & GAS CO | 271.00 | 0.00 | 365 |
| 1995 | SANDBAR OIL & GAS CO | 150.00 | 0.00 | 365 |
| 1996 | SANDBAR OIL & GAS CO | 273.00 | 0.00 | 365 |
| 1997 | SANDBAR OIL & GAS CO | 225.00 | 0.00 | 365 |
| 2001 | TRIPLE C OIL & GAS CO | 315.00 | 0.00 | 365 |
| 2002 | TRIPLE C OIL & GAS CO | 1185.00 | 0.00 | 365 |
| 2009 | TRIPLE C OIL & GAS CO | 493.00 | 0.00 | 365 |
| 2010 | TRIPLE C OIL & GAS CO | 611.00 | 0.00 | 365 |
| 2012 | TRIPLE C OIL & GAS CO | 539.00 | 0.00 | 366 |
| 2013 | TRIPLE C OIL & GAS CO | 502.00 | 0.00 | 365 |
| 2014 | TRIPLE C OIL & GAS CO | 371.00 | 0.00 | 365 |
| 2015 | TRIPLE C OIL & GAS CO | 295.00 | 0.00 | 365 |
| 2016 | TRIPLE C OIL & GAS CO | 142.00 | 0.00 | 365 |
| 2017 | TRIPLE C OIL & GAS CO | 213.00 | 0.00 | 365 |
| 2018 | TRIPLE C OIL & GAS CO | 182.00 | 0.00 | 365 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1984 | MUTUAL OIL & GAS CO | Brine | 0 | 0 |
| 1985 | ATWOOD ENTERPRISES INC | Brine | 0 | 295 |
| 1993 | SANDBAR OIL & GAS CO | Brine | 0 | 365 |
| 1994 | SANDBAR OIL & GAS CO | Brine | 0 | 365 |
| 1995 | SANDBAR OIL & GAS CO | Brine | 0 | 365 |
| 1996 | SANDBAR OIL & GAS CO | Brine | 0 | 365 |
| 1997 | SANDBAR OIL & GAS CO | Brine | 365 | |
| 2001 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2002 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2009 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2010 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2012 | TRIPLE C OIL & GAS CO | Brine | 0 | 366 |
| 2013 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2014 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2015 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2016 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2017 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| 2018 | TRIPLE C OIL & GAS CO | Brine | 0 | 365 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1039572778 | 2017-1-27 0:00: | PW | No Violations | 0.80 |
| 1039572778 | 2017-01-27 | Production Wells | No Violations | Status check inspection found the following equipment present at the well head 4.5 diameter production casing and 1.5 diameter production tubing with casing and tubing well heads present and the well set up to be produced by the means of a pumping unit, production flowlines are in place and hooked to both the casing and tubing well heads with production valves present and both the tubing and casing head valves in the closed position. Both the electrical service and electrical motor along with the pumping unit drive belts are in disrepair and no sign of recent activity is visible around the well head. At the production facility (2) 100 barrel production tanks are present along with a mechanical separator and gas sales meter with a current sales chart in the gas meter. The company is reporting commercial production however the condition of the well in disrepair and the valves closed contradicts the production being reported and multiple wells on the same lease are being feed through one common metering point. |
| 1487122067 | 2017-02-14 | Production Wells | No Violations | On this day I stopped by Baker Equipment Company and discussed the status of the well being shut in and in disrepair with Steve Baker. Mr. Baker indicated there were issues with the production flow line leaking and indicated the well made gas only and produced no fluid when previously pumped. I informed Mr. Baker that he needed to make the repairs needed to put the well back in production. I also provided Mr. Baker with the proper identification information for the 4 wells he is producing on the Joe Mallett lease. |
For data sources see[9]