34-111-24118

Well Details

Well ID: 34-111-24118
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Franklin Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: BETTINGER S
License Status: Producing
License Date: 2007-06-18
Spud Date: 2007-07-08
Spud Drilling Contractor: G & L DRILLING
Final Drill Date: 2007-07-25
Well Total Depth: 2520.00 ft
Configuration: Vertical
Latitude: 39.710000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-06-18 Proposed Formations:BEREA-GORDON, Issued Date:6/18/2007, Expired Date:6/17/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-07-25 WELL INSPECTED BY PAT SHREVE ON 2/5/2008.
Reached Total Depth 2007-07-25 WELL INSPECTED BY PAT SHREVE ON 2/5/2008.
Completion Report Received 2007-10-23 WELL INSPECTED BY PAT SHREVE ON 2/5/2008.
Construction Permit Expires 2008-06-17 WELL INSPECTED BY PAT SHREVE ON 2/5/2008.
Change of Owner 2015-07-10 Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 9086, GENESIS RESOURCES LLC
Record Last Modified 2015-09-24 WELL INSPECTED BY PAT SHREVE ON 2/5/2008.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-11 2080 2118 8
2008-02-11 1969 1973 12
1969 1973 12
2080 2118 8
2246 2264 20
2378 2418 20
1969 1973 12
2008-02-11 2378 2418 20
2008-02-11 2246 2264 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 600 Bbl 0 UNITS FRACED IN OHIO SHALE: GANTZ, THIRTY FOOT, & GORDON SANDSTONES

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 874.00 143.00 140
2008 ALLIANCE PETROLEUM CORPORATION 2185.00 183.00 365
2009 ALLIANCE PETROLEUM CORPORATION 1162.00 76.00 365
2010 ALLIANCE PETROLEUM CORPORATION 941.00 69.00 365
2011 ALLIANCE PETROLEUM CORPORATION 770.00 66.00 365
2012 ALLIANCE PETROLEUM CORPORATION 498.00 28.00 366
2013 ALLIANCE PETROLEUM CORPORATION 606.00 29.00 365
2014 ALLIANCE PETROLEUM CORPORATION 556.00 26.00 365
2015 GENESIS RESOURCES LLC 181.00 0.00 184
2016 GENESIS RESOURCES LLC 374.00 33.00 360
2017 GENESIS RESOURCES LLC 406.00 19.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 140
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 7 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 1 365
2015 GENESIS RESOURCES LLC Brine 0 184
2016 GENESIS RESOURCES LLC Brine 0 360
2017 GENESIS RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1289174245 2015-9-1 0:00:0 PW No Violations 1.00
0198619126 2007-10-23 Preliminary Restoration No Violations Restoration work at site satisfactory, well is equipped with pumping unit and tubing and rods and 1-50 bbl plastic tank and 1-100 bbl tank within dikke area.
1289174245 2015-09-01 Production Wells No Violations Producing well status check inspection found the following equipment present at the well head-4.5 production casing -1.5 production tubing and pumping rods with the well set up to be produced by the means of a pumping unit and the production valves in the open position. At the production fluid storage area (2) 100 barrel production tanks and a 1600 gallon plastic tank are present along with (2) mechanical separators and (2) gas sales meters with current sales charts present, the tank battery is being shared with other wells in the area owned by the operator.
1925387740 2020-7-28 0:00: PW No Violations 1.00
198619126 2007-10-23 0:00 PL No Violations

For data sources see[9]