34-111-24305

Well Details

Well ID: 34-111-24305
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Ohio Township
Operator Name: STATOIL USA ONSHORE PROPERTIES
Well Pad ID: US-OH-000783
Farm/Lease Name: DANGEL
License Status: Plugged Back
License Date: 2011-09-02
Spud Date: 2011-11-09
Spud Drilling Contractor: L WILSON DRLG
Final Drill Date: 2012-01-18
Well Total Depth: 10980.00 ft
Configuration: Vertical
Latitude: 39.670000
Longitude: -80.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-09-02 Proposed Formations:BEREA THRU KNOX, Issued Date:9/2/2011, Expired Date:9/1/2013 12:00:00 PM, Drilling unit acres:156, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2012-01-18
Completion Report Received 2012-05-03
Change of Owner 2012-12-26 Operator changed from 8693, PROTEGE ENERGY II LLC to 9065, STATOIL USA ONSHORE PROP INC
Plugged Back 2013-05-18
Construction Permit Expires 2013-09-01
Record Last Modified 2018-04-06

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-06-12 10716 10720 0
10716 10720 0
10716 10720 0

For data sources see[3]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 STATOIL USA ONSHORE PROPERTIES Brine 3060 10
2015 STATOIL USA ONSHORE PROPERTIES Brine 16422 204
2016 STATOIL USA ONSHORE PROPERTIES Brine 6471 235
2017 STATOIL USA ONSHORE PROPERTIES Brine 6708 365
2018 EQUINOR USA ONSHORE PROPERTIES Brine 4270 345
2019 EQUINOR USA ONSHORE PROPERTIES Brine 849 70

For data sources see[4] [5]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1034745204 2013-5-15 0:00: AM No Violations 1.00
-1496686620 2012-8-20 0:00: PL No Violations
-1551378329 2020-8-13 0:00: PW No Violations 1.50
-1635981385 2013-7-31 0:00: DD No Violations 7.00
-1929694370 2013-5-15 0:00: PB No Violations 2.00
-294244979 2019-1-28 0:00: PW No Violations 0.10
-489598037 2013-10-21 0:00 DD No Violations 0.70
-730585756 2013-5-16 0:00: WR No Violations
-846062423 2013-5-30 0:00: PB No Violations
0294244979 2019-01-28 Production Wells No Violations On this day, I found the pad gated with signage at the entrance. There are (7) producing wells, gas processing units, (6) 400-barrel steel production tanks within steel containment, (4) 30,000 gallon horizontal condensate pressure vessels in containment, and an Emergency Shutdown (ESD) button is present at the pad entrance. Concrete barriers surround the perimeter of the wellheads. Each well has identification and annular pressure monitoring devices equipped. The 9.625 inch diameter intermediate casing does not have a gauge, and the 13.375 inch diameter surface casing has a pressure of 0 psi.
0489598037 2013-10-21 Drill / Deepen / Reopen No Violations Notification was received from the company man on site over the past weekend that they had reached their total drilling depth at 11260 and are running and cementing the 5.5 production casing, upon inspection on this day the well bore drilling is complete and the rig is skidding to 3411124381-0000.
0730585756 2013-05-16 Work Over Reconditioning No Violations On this day I witnessed Mercer Well Svc rigged up on the hole attempting to drill out 3 composite plugs. Once the plugs are drilled out the Utica section shall be plugged back in order for the well to be completed in the Marcellus formation. The company man on site Rick Pace called later this day and indicated they will be ready to plug tomorrow at 12:00 pm.
0846062423 2013-05-30 Plug / Plug Back No Violations The company man Rick Pyles called at 4:45 pm and stated their first attempt to cut the casing at 3750 was unsuccessful and the pipe would not pull or circulate, I advised Him to keep moving up the hole and cutting the pipe until they reached a free point to recover the pipe and set their rip plug.
0863928139 2012-12-20 Production Wells No Violations On the day of my inspection the well was capable of production. No violations noted.
0889083308 2013-10-21 Drill / Deepen / Reopen No Violations Accompanied Inspector Bill Stolarik on inspection. Total depth at the time of inspection was 11260 ft. The hole was 8.5 in in diameter. Spoke with company men on site.
1034745204 2013-05-15 Administrative Inspection No Violations Rick Pyles of Stat Oil called on well about a Plug back job. The Utica perfs are at 10,716-10,720. The Marcellus perfs are at 6188-6191,6216-6219,6310-6313. The top of Cement is at 6170. The Top of the Kick plug will be at 3200-2400.
1184151295 2012-11-30 Production Wells No Violations Inspection of the site found the well completed and waiting on the sales transportation lines to be installed.
1305665608 2013-05-30 Plug / Plug Back No Violations Status check inspection on the company attempting to cut their 5.5 production casing at the top of the cement on the backside. The company was removing the BOP stack and would be several hours and would not be ready to cement until the next morning, The company man Rick Pyles will post me this evening of their progress.
1337277576 2012-05-16 Completion Testing No Violations On day of inspection well was fraced week prior and Weatherford was flowing back well for the company.
1367517886 2013-05-02 Plug / Plug Back No Violations Status check inspection on the plug back process. The company is testing the completed Utica formation and has Schulumberger completion and cementing service standing by on location. The company man will notify me when they are ready to set the bottom plug.
1368576145 2013-05-14 Work Over Reconditioning No Violations Status check inspection found Mercer Well Svc work over rig rigging up snubbing unit well head control and service related equipment preparing to set the Utica plug and pull the 5.5 production casing.
1369143025 2013-05-18 Plug / Plug Back No Violations On site inspection to witness the setting of the 2 bottom hole plugs over the Utica and Marcellus shale sections, Upon arrival the well bore production casing had 3500 psi on it and a 180 barrel 10.8# fluid pill was used to kill the well, Schlumberger well services are the cement contractors scheduled on location for 9:30 AM but did not arrive until 3:30 Pm, A 900 bottom hole plug was set and a 449 Marcellus plug was set from 6612 to 6163, with the intention of setting a cast iron bridge plug on top of the cement and ripping the pipe at the annular cement top and setting a 600 rip plug properly covering the Marcellus on the Annular of the 5.5 that did not have proper coverage on the initial well bore completion process.
1369167747 2013-05-21 Plug / Plug Back No Violations On this day we ran tubing and a tooth bit in to check the top plug set on 05/18/2013, The plug was to be set from 6612 to 6163. The plug was not in place or encountered. The company circulated the hole clean and shall place a cast iron bridge plug below the bottom perforation and will re cement this section accordingly.
1369316877 2013-05-22 Plug / Plug Back No Violations On site inspection to witness the plugging of the Marcellus formation, A cement plug was set inside of the 5.5 production covering a perforated section that was tested to check the Frack gradient, The plug was set from 6773 to 6163 and a cast iron bridge plug was set at 6160 at the approximate height of the cement on the backside of the 5.5 annular space. The casing will be shot off tomorrow just above the cast iron plug and a 400 cement rip plug shall be set to complete the Marcellus zonal isolation.
1369702612 2013-05-23 Plug / Plug Back No Violations On site inspection to witness the company attempting to cut the 5.5 production casing at the top of the cement above the Marcellus production zone. The service company was unable to pull stretch on the casing to get the casing out of the well head slips due to the casing being set in the slips 120,000 pounds over string weight by the drilling rig. The company continued to work on the project the next day with no success.
1369833593 2013-05-28 Plug / Plug Back No Violations Status check inspection on the plugging back of the Utica Formation. I will note that the Halliburton cement bond log that the company had on file showed a cement top on the backside of the 5.5 production casing at 6170 and this is the depth we have been working off of trying to cut the casing and isolate the top of the Marcellus. On this day Grey wire line company re-bond logged the well and found the cement top to be at approximately 3850. The company will run in the hole with tubing and finish setting the top of the Marcellus plug inside the 5.5 producing casing on 05/29/13 and then finish plugging the well accordingly.
1369865532 2013-05-29 Plug / Plug Back No Violations On site status check inspection to witness the setting of the plug inside of the 5.5 production casing on top of the Marcellus formation. Upon arrival I found that the rig crew had set the tubing string down in the last cement set in the casing plugging it up as not to allow circulation. The rig crew removed the plugged tubing joint and will run back in and set a 450 plug.
1370016173 2013-05-31 Plug / Plug Back No Violations Plugging inspection found the company trying to cut and pull the 5.5 production casing. The casing was cut with a jet cut wire line cutting tool at 3600 and a collar buster at 3422 with good telegraph to surface on both cuts but the casing will still not pull due to it being set in the slips by the drilling rig at 135,000# over string weight. A set of hydraulic casing jacks were brought in to try and lift the casing out of the slips. A mechanical plug was set at 3750.
1370141807 2013-06-01 Administrative Inspection No Violations I received phone notification from the company man on site Rick Pyles that they were able to free the 5.5 production casing from the well head slips with the assist from the casing jacks by lifting 400,000 pounds on the casing and pressuring 1100 psi on the annular on the casing. The company will try tomorrow to cut the casing again at 3422 with a collar buster explosive shot.
1370306729 2013-06-03 Plug / Plug Back No Violations On site inspection to witness the kick & rip plug being set on this day. The casing was ripped at 3422 and pulled out of the hole. 2.375 tubing was ran back in to a depth of 3433 and a cement plug set from 3433 to 2376. The well was circulated at 2376 and the plug shall be tagged tomorrow morning.
1370392938 2013-06-04 Plug / Plug Back No Violations On this day the rig crew ran in with tubing and tagged the top of the kick plug at 2400 and pressure tested the 9.625 casing at 2800 psi.
1370445706 2013-06-05 Plug / Plug Back No Violations The plug back is complete and the rig is rigging down and moving off the hole. The big rig is due in sometime in July. I reviewed the plug back records with Rick Pyles and confirmed that all records corresponded.
1496686620 2012-08-20 Preliminary Restoration No Violations On the day of my inspection the well site was restored in accordance with the preliminary restoration requirements. Preliminary restoration is now passed.
1635981385 2013-07-31 Drill / Deepen / Reopen No Violations
1642064757 2015-01-14 Preliminary Restoration No Violations Shale well preliminary restoration status check inspection found the said well has had the drilling and completion process completed and multiple wells are producing on the well pad with the following production related equipment in place on the location. There are 7 total wells on location each with individual gas processing units and a total of 4 -3,000 gallon 150 psi cylindrical vessels used for condensate along with 4-400 barrel production water tanks. Preliminary Restoration passed.
1835808091 2013-05-17 Plug / Plug Back No Violations 12:00 PM call out to begin plugging back the Completed Utica formation to complete the Marcellus section. Upon arrival the company man informed me that the job was postponed until tomorrow morning -Saturday 05/18/2013 @ 9:00Am, I contacted my supervisor and received permission to work a maximum of 8 hours overtime only.
1929694370 2013-05-15 Plug / Plug Back No Violations Status check inspection found Mercer Well Svc running tubing into the hole to drill out composite bridge plugs set during a Frac Gradient test. The current tubing depth is 6,000 with the 1st plug set @ 6,250. Once the plugs are removed the company will pull the tubing and remove the drill bit and run in open ended and set the bottom plug over the Utica formation and then plug the well back accordingly.
1948458190 2013-05-08 Work Over Reconditioning No Violations On site inspection found the company running in the hole with 1.250 coil tubing to a depth of 6,000 to try and make an attempt to kill the completed Utica formation in order to change out the production well head and replace it with a completion well head.
2035963821 2013-10-15 Drill / Deepen / Reopen No Violations Status check inspection of the current drilling progress found the current drilling depth to be 5781 with a TVD of 5685 using a 8.5 directional drilling tool with a current curve being built at 16 degrees with a Azimuth of 175 degrees. Pressure test of the 9.625 previous casing string was done on 10/14/13 to a pressure of 2800 psi with no recorded loss, A formation leak off and integrity test was also done and recorded.
863928139 2012-12-20 0:00 PW No Violations 0.50
889083308 2013-10-21 0:00 DD No Violations 1.50

For data sources see[6]