Well Details

Well ID: 34-111-24580
Country: United States
State: Ohio
County: Monroe
Municipality: Salem Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001257
Farm/Lease Name: DIETRICH C
License Status: Drilling
License Date: 2015-05-08
Spud Date: 2015-07-06
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth: 113.00 ft
Configuration: Horizontal
Latitude: 39.780000
Longitude: -80.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-05-08 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:5/8/2015, Expired Date:5/7/2017 12:00:00 PM, Drilling unit acres:685.788, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2015-07-31 UPDATE TO UNIT SIZE AND LANDOWNER ROYALTY LIST.
Record Last Modified 2017-02-10
Construction Permit Expires 2017-05-07

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1717951869 2018-2-27 0:00: ND No Violations 0.20
-647036397 2016-4-5 0:00:0 PL No Violations 0.50
-965458177 2015-7-8 0:00:0 CS No Violations 3.50
0647036397 2016-04-05 Preliminary Restoration No Violations Preliminary Restoration status check inspection found the area affected by the well site construction meets ORC 1509.072 with erosion control and vegetation established. Addressing the well - to date only the conductor casing has been set.
0965458177 2015-07-08 Casing String Witnessed No Violations I am onsite to witness the conductor cementing operations. Precision Rathole drilled 113 of 36 borehole and installed 113 of 30 weld casing. Universal cemented the casing in place with 109 barrels of Type 1 cement with 3% CaCl and .25 pounds per sack of Flowseal. I witnessed 25 barrels of cement circulate to surface. Eighteen inches of cement was left in the cellar to provide a liquid tight seal.
1717951869 2018-02-27 Not Drilled No Violations Status check inspection to document the well has been spudded and the conductor set, however the well was not drilled past the conductor and a steel plate is covering the cellar and conductor on the day of my inspection. (2) wells have been drilled and completed on the pad.

For data sources see[3]