X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-24630

Well Details

Well ID: 34-111-24630
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Salem Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001390
Farm/Lease Name: MOSER A
License Status: Producing
License Date: 2016-07-20
Spud Date: 2016-09-04
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2016-10-01
Well Total Depth: 19007.00 ft
Configuration: Horizontal
Latitude: 39.780000
Longitude: -80.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-10-30 Proposed Formations:TRENTON, Issued Date:10/30/2015, Expired Date:10/29/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:STRT
APP 2016-07-20 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:7/20/2016, Expired Date:7/20/2018 12:00:00 PM, Drilling unit acres:651.991, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2016-10-01
Correction to Well 2017-03-24 UPDATE TARGET/TAKEPOINT PER AS-DRILLED PLAT-RC
Completion Report Received 2017-07-14
Record Last Modified 2018-02-22
Construction Permit Expires 2018-07-20

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-08-23 11197 11294 36
2017-08-23 18748 18850 27
18748 18850 27
11197 11294 36
11197 11294 36

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/21/2017 04/27/2017 10640 20,937,900.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HP-9601 OneAqua Source Additive Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
HP-2814 OneAqua Source Friction Reducer Listed Below Listed Below 0 0 0
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 30 0.00004137 83
Ammonium chloride 12125-02-9 1.5 0.000542667 1079
Heavy aromatic petroleum naphtha 64742-94-5 30 0.00004204 84
Propargyl alcohol 107-19-7 10 0.00001379 28
Naphthalene 91-20-3 5 0.00000701 14
Ethanol 64-17-5 60 0.00008408 168
Crystalline silica, quartz 14808-60-7 100 11.6133 23,089,300.0
Dazomet 533-74-4 24 0.0053498 10637
Ethoxylated alcohols Proprietary 30 0.00004137 83
Fatty acids, tall oil Proprietary 30 0.00004137 83
Hydrochloric acid 7647-01-0 15 0.02741 54501
Ammonium Chloride 12125-02-9 1.5 0.00004091 82
Ammonium Persulfate 7727-54-0 100 0.001859 3696
Olefins Proprietary 5 0.00001655 34
Organic phosphate copolymer 71050-62-9 25 0.0030433 6051
Phenol / formaldehyde resin 9003-35-4 5 0.0188842 37546
Poly(oxy-1,2-ethanediyl), alpha-(4-nonylphenyl)-omega-hydroxy-,

branched

127087-87-0 5 0.00000701 14
Sodium Hydroxide 1310-73-2 4 0.000891634 1773
1,2,4 Trimethylbenzene 95-63-6 1 0.00000140 3
Acetic anhydride 108-24-7 100 0.000833732 1658
Acetic acid 64-19-7 60 0.000500239 995
Hexamethylenetetramine 100-97-0 2 0.00755368 15018
Distillates (petroleum, hydrotreated light) 64742-47-8 18 0.00700295 13924
Methanol 67-56-1 60 0.00008274 165
Oxyalkylated phenolic resin Proprietary 30 0.00005605 112
SAND-PREMIUM WHITE-40/70 Halliburton Proppant Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
OILPERM A Halliburton Non-ionic Surfactant Listed Below Listed Below 0 0 0
SAND-CRC PREMIUM-30/50 Halliburton Proppant Listed Below Listed Below 0 0 0
HP-2816 OneAqua Source Additive Listed Below Listed Below 0 0 0
MB-7530 OneAqua Source Biocide Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 82.722 164,465,000.0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.182751 363340
SAND-COMMON WHITE-100 MESH Halliburton Proppant Listed Below Listed Below 0 0 0
HP-2220 OneAqua Source Scale Inhibitor Listed Below Listed Below 0 0 0
Produced Water Operator Base Fluid Water 7732-18-5 100 5.40561 10,747,300.0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2017-03-21 H2O 15 500656 Gal 545800 Halliburton STAGE 1/35

STAGES 2-34 SEE IMAGES

2017-04-27 H2O 15 704753 Gal 799400 Halliburton STAGE 35/35

STAGES 2-34 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 ECLIPSE RESOURCES I LP 3216441 0 209
2018 ECLIPSE RESOURCES I LP 1762220 0 362
2019 ECLIPSE RESOURCES I LP 284395 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 ECLIPSE RESOURCES I LP Brine 48149 209
2018 ECLIPSE RESOURCES I LP Brine 19465 362
2019 ECLIPSE RESOURCES I LP Brine 3186 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1186759612 2016-9-20 0:00: DD No Violations 1.50
-621093765 2016-9-14 0:00: DD No Violations 1.00
0621093765 2016-09-14 Drill / Deepen / Reopen No Violations Status check inspection accompanied by ODNR Inspector Austin Gutridge found H&P Drilling rig 531 on location and the 17.5 1st intermediate well bore total drilling depth recently reached at 2,500 with 2,464 of 13.375 Buttress thread casing set and cemented. Currently KLX Energys wireline service is on location running a casing bond log.
1186759612 2016-09-20 Drill / Deepen / Reopen No Violations
1259226407 2016-09-10 Drill / Deepen / Reopen No Violations The purpose of my inspection is to witness cement being spotted to seal up a leaking casing shoe. During my inspection KLX Energy Services and Schlumberger were on location. KLX Energy Services ran a temperature log to locate the fluid level within the well. The log revealed a temperature change at 625 feet insinuating that is where the top of the fluid exist. Following the log Schlumberger rigged up and pumped a 300 foot plug of 91 barrels of class A cement at 16.4 pounds per gallon through the drill pipe. The drill pipe was removed and the plug was tagged at 720 feet. A second cement plug consisted 200 foot of 62.5 barrels of class A cement at 16.4 pounds per gallon. The top of the cement was tagged at 520 feet. The leaking casing shoe is now sealed.
1469572850 2016-07-26 Casing String Witnessed No Violations 07/26/2016- On site inspection to witness the conductor casing cement job. Precision Rat hole has drilled a 36 x 120 conductor borehole with no surface water encountered. 120 of 30 x .375 wall with weld connections conductor pie was ran. Universal Well Service cement company cemented the casing using 471 sacks of Type 1 cement with circulation established and 10 barrels of 6% gel ran ahead of he cement. Cement returns were witnessed at 60 barrels into a total of 91 barrels of fresh water displacement with cement visible inside the cellar and cement staying up to surface level.
1473256184 2016-09-06 Casing String Witnessed No Violations 09/06/2016 On site inspection to witness the surface-mine string cement job; H&P Drilling rig 531 is on location and has drilled a 24 borehole to 918 with the mine void encountered at 787 to 797 and 832 of 18.625 casing set with a 2 stage tool at 669 and packer at 670. Schlumberger cemented the bottom section below the mine void with 301 sacks of class A cement, the cement plug was landed and the swell packer inflated at 220 psi; the tool was then deployed to open the cement stage tool with the casing internal pressure being increased to 1,400 psi and the tool not opening. I left location at 7:30 pm with the company waiting on a wireline service to arrive. It was then reported by phone that the company went in with a weight bar and struck down on the DV tool allowing the stoke and establish circulation; the top section was then cemented.
1473674368 2016-09-10 Drill / Deepen / Reopen No Violations On the morning of 09/10/2016 the company notified me that the 18.625 mine string casing shoe pressure test failed and would not hold a hydrostatic Colum of fluid. Multiple members of Eclipse Drilling Engineering staff contacted me by phone on the morning of September 10th 2016 and questioned my request to repair the failed casing shoe. I informed the company that they had a failed casing shoe on a mine string and the mine void encountered during the drilling of the well bore was not sealed and would communicate. Also noted was the large volume of gas encountered during the drilling of the mine string, the gas presence was significant enough to carry a flair until the top section was sealed. I explained to all parties that under 1501:9-1-08 of the well construction rules; under section E the casing shoe test could be required and remedial action be requested.
1493128120 2017-04-25 Completion Testing No Violations On site inspection as a response to complaint # 5589 received on 04/24/2017. Upon inspection of the well site it was observed that Halliburton Pressure pumping service was on location and standing by to stimulate stage 34 of 35 total stages to be stimulated. Nine Energy wireline service has perforated the 34th stage between the depths of 11,428 and 11,325 with 20 perforations shot in 4 clusters. The well is being stimulated through 15,000 psi pressure rated flow line iron with a FMC completion well head in place with both a manual and hydrologic controlled master valve in place on the well head. Annular pressure monitoring is in place on the well head annulis. All stimulation support equipment on location is placed on polymer containment with the well site earthen berm serving as the primary containment.
1580126211 2017-08-31 Preliminary Restoration No Violations Preliminary Restoration status check inspection found the well site meets ORC 1509.072 with the area affected by the well pad construction restored and vegetation established. The well pad perimeter is fenced with a 8 chain link fence and signage posted at the well pad entrance as well as at each well head and at the tank battery. Emergency shut down devices are located at the well pad entrance the tank battery and Gas processing units and also inside the remote transmission unit building, and finally at the well head. On location a total of (8) wells are present with all wells drilled- stimulated and completed with the production valves in the open position at the well head. Also present on the well heads is annular pressure monitoring gauges with zero pounds pressure showing between the 13.375 and 9.625, and zero psi between the 5.5 and 9.625. The company is monitoring and addressing any annular pressure. On the South side of the well pad is the production facility consisting of a total of (4) steel construction production tanks with a total of 400 barrels fluid capacity each. On the East side of the well pad is the production filtration and separation equipment consisting of a total of (8) gas processing units and (2 )dehydration units. Directly on the North East side of the well pad is the gas distribution point where the gas product is transferred over to Eureka Midstream.
1682346391 2016-09-28 Drill / Deepen / Reopen No Violations On the morning of 06/28/2016 I was informed by phone by the company man on site that the total drilling depth had been reached at 19,007 and they were preparing to condition the hole and pull the drill string with anticipation of running 18,990 of 5.5 production casing.
1952466600 2020-4-17 0:00: PW No Violations 0.30

For data sources see[10]

References