If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-111-24674 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.82,"lon":-80.94,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Monroe | |
Municipality: Switzerland Township | |
Operator Name: CNX GAS COMPANY LLC | |
Well Pad ID: US-OH-001403 | |
Farm/Lease Name: FRANCES I KINZEY ET UX | |
License Status: Producing | |
License Date: 2016-09-27 | |
Spud Date: 2016-11-12 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2017-01-15 | |
Well Total Depth: 20426.00 ft | |
Configuration: Horizontal | |
Latitude: 39.820000 | |
Longitude: -80.940000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2016-09-27 | Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:9/27/2016, Expired Date:9/27/2018 12:00:00 PM, Drilling unit acres:496.1, Proposed Well Type:OG, Proposed Well Class:NWC |
Reached Total Depth | 2017-01-15 | STATUS UPDATED FROM PRODUCTION |
Completion Report Received | 2017-12-21 | STATUS UPDATED FROM PRODUCTION |
Correction to Well | 2018-01-05 | UPDATE TARGET/TAKE PER AS-DRILLED PLAT |
Record Last Modified | 2018-09-14 | STATUS UPDATED FROM PRODUCTION |
Construction Permit Expires | 2018-09-27 | STATUS UPDATED FROM PRODUCTION |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-12-28 | 10904 | 11078 | 0 |
2017-12-28 | 20065 | 20216 | 0 |
20065 | 20216 | 0 | |
10904 | 11078 | 0 | |
10904 | 11078 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 06/06/2017 | 06/29/2017 | 10387 | 19,369,900.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HCL Acid (7.5%) | UPP | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.00963369 | 18003.6 |
AP Breaker | UPP | Gel breaker | Ammonium peroxydisulfate | 7727-54-0 | 100 | 0.000765725 | 1431 | |
Sulfuric acid | 7664-93-9 | 0.5 | 0.00000383 | 7.155 | ||||
Sand | UPP | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 99.9 | 8.63877 | 16,144,300.0 | |
WGA-7 | UPP | Viscosifier | Guar Gum | 9000-30-0 | 55 | 0.0344996 | 64473.5 | |
Distillates (petroleum), hydrotreated light | 64742-47-8 | 55 | 0.0344996 | 64473.5 | ||||
Scale Inhibitor E | UPP | Scale Inhibitor | Copolymer of Maleic and Acrylic Acid | 52255-49-9 | 20 | 0.00268568 | 5019.05 | |
DETA phosphonate | 15827-60-8 | 5 | 0.000671421 | 1254.76 | ||||
Hexamethylene Triamine Penta(Methylene Phosphonic Acid) | 34690-00-1 | 5 | 0.000671421 | 1254.76 | ||||
Unislick ST50 | UPP | Friction reducer | Ammonium acetate | 631-61-8 | 13 | 0.0083925 | 15684 | |
Alcohols, ethoxylated | 68002-97-1 | 5 | 0.00322789 | 6032.32 | ||||
Alcohols, ethoxylated | 68439-50-9 | 5 | 0.00322789 | 6032.32 | ||||
Alcohols, ethoxylated | 68551-12-2 | 5 | 0.00322789 | 6032.32 | ||||
Petroleum distillates, hydrotreated light | 64742-47-8 | 30 | 0.0193673 | 36194 | ||||
Unihib G | UPP | Acid inhibitor | Butyl diglycol | 112-34-5 | 75 | 0.00060112 | 1123.38 | |
Alcohols, C10-16, ethoxylated | 68002-97-1 | 50 | 0.000400747 | 748.922 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000801 | 14.978 | ||||
Methanol | 67-56-1 | 5 | 0.00004007 | 74.892 | ||||
Thiourea | 62-56-6 | 1 | 0.00000801 | 14.978 | ||||
Ceramic Proppant | Carbo Ceramics | Proppant | Ceramic materials and wares, chemicals | 66402-68-4 | 100 | 3.69272 | 6,901,020.0 | |
Water | Consol | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.494 | 161,641,000.0 | |
HCL Acid (15%) | UPP | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.132975 | 248507 | |
Other Chemical(s) | Listed Above | See Trade Name(s) List | Ethanol | 64-17-5 | 0.3 | 0.00002583 | 48.271 | |
Methanol | 67-56-1 | 5 | 0.00004007 | 74.892 | ||||
Sulfuric acid | 7664-93-9 | 0.5 | 0.00000383 | 7.155 | ||||
Alcohols, ethoxylated | 68439-50-9 | 5 | 0.00322789 | 6032.32 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000801 | 14.978 | ||||
Alcohols, C10-16, ethoxylated | 68002-97-1 | 50 | 0.000400747 | 748.922 | ||||
Hexamethylene Triamine Penta(Methylene Phosphonic Acid) | 34690-00-1 | 5 | 0.000671421 | 1254.76 | ||||
Alcohols, ethoxylated | 68002-97-1 | 5 | 0.00322789 | 6032.32 | ||||
Alcohols, ethoxylated | 68551-12-2 | 5 | 0.00322789 | 6032.32 | ||||
Thiourea | 62-56-6 | 1 | 0.00000801 | 14.978 | ||||
DETA phosphonate | 15827-60-8 | 5 | 0.000671421 | 1254.76 | ||||
Water | 7732-18-5 | 83 | 0.00714629 | 13355.1 | ||||
Quarternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 2.5 | 0.00021525 | 402.262 | ||||
Ammonium acetate | 631-61-8 | 13 | 0.0083925 | 15684 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 55 | 0.0344996 | 64473.5 | ||||
Aqucar 714 | UPP | Biocide | Ethanol | 64-17-5 | 0.3 | 0.00002583 | 48.271 | |
Quarternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 2.5 | 0.00021525 | 402.262 | ||||
Water | 7732-18-5 | 83 | 0.00714629 | 13355.1 | ||||
Glutaraldehyde | 111-30-8 | 14 | 0.0012054 | 2252.67 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-06-29 | H2O | 15 | 9949 Bbl | 500500 | Universal Well Services Inc. | STAGE 47/47
STAGES 2-46 SEE IMAGES |
H2O | 15 | 13172 Bbl | 502000 | Universal Well Services Inc. | STAGE 1/57
STAGES 2-46 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CNX GAS COMPANY LLC | 2017058 | 0 | 103 |
2018 | CNX GAS COMPANY LLC | 4170735 | 0 | 360 |
2019 | CNX GAS COMPANY LLC | 541533 | 0 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CNX GAS COMPANY LLC | Brine | 67867 | 103 |
2018 | CNX GAS COMPANY LLC | Brine | 74241 | 360 |
2019 | CNX GAS COMPANY LLC | Brine | 10005 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1456894150 | 2018-8-6 0:00:0 | PL | No Violations | 0.30 |
-1996222864 | 2017-12-27 0:00 | CT | No Violations | |
1065109811 | 2018-08-06 | Preliminary Restoration | No Violations | Preliminary restoration status check inspection found the well site meets ORC 1509.072 with vegetation established and erosion control in the area affected by the well pad construction. The well pad surface and lease road has a stone surface and is in good repair. There is a EQT midstream transmission point on the right rear corner of the well pad. Fire extinguishers and emergency shut down well control devices are situated at all critical areas of the well pad along with the well pad muster points. 4 wells are present on the pad. The well head consists of a lower A and upper B section along with a production tree. Present at surface inside the cellar and attached to the A & B section are riser pipes and valves with mechanical and electronic gauges present. The A section pressure gauge which is the 13.375 diameter casing string internal pressure between the 13.375 and 9.625 casing strings showed 150 pounds per square inch (psi). The B section valve which is the internal pressure on the 9.625 diameter casing (between the 9.625 and 5.5) showed 1,014 psi. The 5.5 diameter casing internal pressure gauge read 2,039 psi and the tubing head pressure gauge showed 1,228 psi. Immediately on the right upon entering the well pad is the production facility consisting of 4 steel construction 400 fluid barrel capacity storage tanks all situated inside a polymer lined steel containment dike area. |
1323621832 | 2016-11-13 | Casing String Witnessed | No Violations | The purpose of my inspection today is to witness the 100 feet deep 30 inch diameter conductor being cemented into a 36 inch diameter hole. No water was encountered during the drilling process. Express Energy Services is here to complete the cement operation. During my inspection Express Energy services used 275 sacks of Class A cement at 15.6 pounds per gallon and displaced with 75 barrels of water. 20 barrels of cement returns were achieved. |
1456894150 | 2018-08-06 | Preliminary Restoration | No Violations | Preliminary restoration status check inspection found the well site meets ORC 1509.072 with vegetation established and erosion control in the area affected by the well pad construction. The well pad surface and lease road has a stone surface and is in good repair. There is a EQT midstream transmission point on the right rear corner of the well pad. Fire extinguishers and emergency shut down well control devices are situated at all critical areas of the well pad along with the well pad muster points. 4 wells are present on the pad. The well head consists of a lower A and upper B section along with a production tree. Present at surface inside the cellar and attached to the A & B section are riser pipes and valves with mechanical and electronic gauges present. The A section pressure gauge which is the 13.375 diameter casing string internal pressure between the 13.375 and 9.625 casing strings showed 301 pounds per square inch (psi). The B section valve which is the internal pressure on the 9.625 diameter casing (between the 9.625 and 5.5) showed 1,014 psi. The 5.5 diameter casing internal pressure gauge read 2,039 psi and the tubing head pressure gauge showed 1,228 psi. Immediately on the right upon entering the well pad is the production facility consisting of 4 steel construction 400 fluid barrel capacity storage tanks all situated inside a polymer lined steel containment dike area. |
1483452802 | 2017-01-03 | Drill / Deepen / Reopen | No Violations | During my inspection the Patterson Drilling Rig 801 was drilling the 12.25 inch diameter borehole at a depth of 7336 feet. |
1796797961 | 2020-8-4 0:00:0 | PW | No Violations | 1.50 |
1956050920 | 2016-12-27 | Casing String Witnessed | No Violations | The purpose of my inspection today is to witness the surface-mine string cement job. Patterson Drilling Rig 801 drilled a 24 inch diameter borehole to a depth of 670 feet. The mine zone is from 575 feet to 600 feet in depth. The 18.625 inch diameter casing was run to a depth of 646 feet. Allied Cement Services is on location to cement this casing string in two stages with a packer set at 344 feet. 197 barrels of fresh water, 50 barrels of gel, and 10 barrels of fresh water were pumped ahead of the cement. 50 barrels of Class A cement with 1.5 percent calcium and 193.5 barrels of displacement were pumped to complete the first stage. The plug landed and the packer was energized. The second stage was completed using 200 barrels of fresh water, 25 barrels of gel, 5 barrels of fresh water, and 176 barrels of Class A cement with 1.5 percent calcium. 104 barrels of displacement were pumped and an estimated 70 barrels of cement returns were witnessed in the cellar. |
1996222864 | 2017-12-27 | Completion Testing | No Violations | Status check inspection found the well drilling - |
2139932367 | 2018-06-20 | Production Wells | No Violations | Status check inspection found there is 4 producing wells on the pad. All wells have had the drilling and completion process complete and are in production. The well are producing off the production tree with emergency shut down devices in line. Annular pressure monitoring is in place with 1,075 psi showing between the 5.5 and 9.625 and 255 psi showing between the 9.625 and 13.375. On site is 4 gas processing units and a production facility consisting of 4 steel tanks capable of holding 400 barrels capacity each. The tanks are situated inside a polymer lined steel containment dike area. . I spoke with Consol regarding clarification on the pressure readings on the well head annulis and filling in the drilling rig mouse holes. There also was some house keeping issues addressed. |
For data sources see[10]