If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-111-24725 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.63,"lon":-80.94,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Monroe | |
Municipality: Lee Township | |
Operator Name: ECLIPSE RESOURCES I LP | |
Well Pad ID: US-OH-001421 | |
Farm/Lease Name: DAVID STALDER B | |
License Status: Producing | |
License Date: 2017-02-17 | |
Spud Date: 2017-03-05 | |
Spud Drilling Contractor: H&P DRILLING | |
Final Drill Date: 2017-04-05 | |
Well Total Depth: 19881.00 ft | |
Configuration: Horizontal | |
Latitude: 39.630000 | |
Longitude: -80.940000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-02-17 | Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:2/17/2017, Expired Date:2/17/2019 12:00:00 PM, Drilling unit acres:686.418, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2017-03-10 | UPDATE ACREAGE/DRILL UNIT PER PROPOSED PLAT-ALE |
Reached Total Depth | 2017-04-05 | |
Correction to Well | 2017-09-15 | UPDATE TARGET/TALE/ACREAGE PER AS-DRILLED PLAT |
Completion Report Received | 2018-02-13 | |
Record Last Modified | 2018-02-22 | |
Construction Permit Expires | 2019-02-17 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-02-20 | 11391 | 11529 | 36 |
2018-02-20 | 19613 | 19718 | 3 |
19613 | 19718 | 3 | |
11391 | 11529 | 36 | |
11391 | 11529 | 36 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/17/2017 | 10/24/2017 | 10912 | 19,077,500.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | OILPERM A | Halliburton | Non-ionic Surfactant | Listed Below | Listed Below | 0 | 0 | 0 |
HP-2814 | OneAqua | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 77.5146 | 141,809,000.0 | |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 0.279123 | 510640 | |
HP-2220 | OneAqua | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
Methanol | 67-56-1 | 60 | 0.000109361 | 201 | ||||
Ethanol | 64-17-5 | 60 | 0.000128419 | 235 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.00001148 | 21 | ||||
Heavy aromatic petroleum naphtha | 64742-94-5 | 30 | 0.00006421 | 118 | ||||
Poly(oxy-1,2-ethanediyl), alpha-(4-nonylphenyl)-omega-hydroxy-,
branched |
127087-87-0 | 5 | 0.00001070 | 20 | ||||
1,2,4 Trimethylbenzene | 95-63-6 | 1 | 0.00000214 | 4 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 11.7545 | 21,504,300.0 | ||||
Sodium hydroxide | 1310-73-2 | 4 | 0.000980337 | 1794 | ||||
Phenol / formaldehyde resin | 9003-35-4 | 5 | 0.0172583 | 31574 | ||||
Oxyalkylated phenolic resin | Proprietary | 30 | 0.00008561 | 158 | ||||
Distillates (petroleum,hydrotreated light) | 64742-47-8 | 18 | 0.0117755 | 21543 | ||||
Propargyl alcohol | 107-19-7 | 10 | 0.00001823 | 34 | ||||
Dazomet | 533-74-4 | 24 | 0.00588202 | 10761 | ||||
Ethoxylated alcohols | Proprietary | 30 | 0.00005468 | 101 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.04187 | 76596 | ||||
Ammonium persulfate | 7727-54-0 | 95 | 0.00261719 | 4788 | ||||
Acetic acid | 64-19-7 | 60 | 0.000764034 | 1398 | ||||
Hexamethylenetetramine | 100-97-0 | 1 | 0.00345166 | 6315 | ||||
Mullite | 1302-93-8 | 100 | 0.345166 | 631462 | ||||
Naphthalene | 91-20-3 | 5 | 0.00001070 | 20 | ||||
Ammonium chloride | 12125-02-9 | 1.15 | 0.000752321 | 1377 | ||||
Organic phosphate copolymer | 71050-62-9 | 25 | 0.00328215 | 6005 | ||||
Fatty acids, tall oil | Proprietary | 30 | 0.00005468 | 101 | ||||
Olefins | Proprietary | 5 | 0.00002187 | 42 | ||||
Acetic anhydride | 108-24-7 | 100 | 0.00127339 | 2330 | ||||
Modified thiourea polymer | Proprietary | 30 | 0.00005468 | 101 | ||||
SAND-PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
HP-9601 | OneAqua | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
PROP-RC CERAMIC-30/50, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
SAND-COMMON WHITE-100 MESH | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
Produced Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 10.1026 | 18,482,200.0 | |
MB-7530 | OneAqua | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
FE-1A ACIDIZING COMPOSITION | Halliburton | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-10-16 | H2O | 15 | 443129 Gal | 474190 | Halliburton | STAGE 45/45
STAGES 2-44 SEE IMAGES |
2017-09-17 | H2O | 15 | 452671 Gal | 485508 | Halliburton | STAGE 1/45
STAEGS 2-44 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ECLIPSE RESOURCES I LP | 91508 | 0 | 8 |
2018 | ECLIPSE RESOURCES I LP | 4131080 | 0 | 362 |
2019 | ECLIPSE RESOURCES I LP | 394195 | 0 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | ECLIPSE RESOURCES I LP | Brine | 4542 | 8 |
2018 | ECLIPSE RESOURCES I LP | Brine | 74041 | 362 |
2019 | ECLIPSE RESOURCES I LP | Brine | 4417 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1318004241 | 2017-3-10 0:00: | DD | No Violations | 1.50 |
-1350044015 | 2017-3-9 0:00:0 | DD | No Violations | 1.50 |
-1389549699 | 2020-8-18 0:00: | PW | No Violations | 1.60 |
-2004764639 | 2017-2-19 0:00: | CS | No Violations | 3.00 |
-2089487910 | 2018-8-21 0:00: | PW | No Violations | 0.30 |
0655868364 | 2017-10-03 | Completion Testing | No Violations | On the day of my inspection, I accompanied ODNR Engineer Technician Andrew Thomas. We were on location to examine a fluid release that occurred. Upon inspection, we found Halliburton on location completing the wells and S3 Pump Service running logging tools down hole. Also, we observed cleanup efforts for recent release. It was indicated that flange bolts broke on the high-pressure side of a pumping unit and released flowback fluid on containment and the pad surface. It was stated that the release contained approximately 40 barrels of flowback fluid. Contaminated materials are being dug up and stockpiled, then hauled from location in roll-off bins by Cowboy Industries. The materials will be taken to a facility to be tested. Containment liner beneath the frac trucks was ripped and indicated seepage to the pad surface. Small trenches are being dug to assist in the collection and removal of fluid. More environmental investigation may be needed to assess total impact to the pad surface and sub-surface. Bruce Carpenter was contacted by Andrew Thomas and explained the situation. Bruce said he would contact ODNR when they would do the investigation. |
1318004241 | 2017-03-10 | Drill / Deepen / Reopen | No Violations | |
1350044015 | 2017-03-09 | Drill / Deepen / Reopen | No Violations | |
1488865933 | 2017-03-07 | Casing String Witnessed | No Violations | On site inspection to witness the surface casing cement job arriving at 23:00 hours on 03/06/2017 to attend the safety meeting and witness the 13.375 surface casing cement job with H&P Drilling rig 608 on location along with Schlumberger Cement service contractors. Upon arrival I was informed the rig was unable to land the last 2 casing joints due to hole conditions and would lay one casing joint down and load the hole with fresh water and circulate the last joint in the hole. The rig had drilled the 17.5 diameter production borehole to a measured depth of 1,872 and ran a 13.375 split weight casing string with 547.8 of 61 lb/ft J-55 grade casing on the bottom of the string and 1,231.31 of 54.5 lb/ft J-55 buttress thread on the upper section of the string with a total of 1,777.11 of 13.375 casing ran with a float shoe and float collar casing equipment ran. At 4:45 am on 03/07/17 the casing was landed, the cement head installed and the safety meeting held. The cement job was began at 5:00 am by pumping 20 barrels of 6% gel spacer followed by 320 barrels cement consisting of 1,485 sacks of class A cement. The cement was displaced with 267 barrels of fresh water and the casing was pressure tested to 500 psi over cement displacement pressure upon the landing of the cement plug in the float collar. Cement returns were witnessed to surface. |
1490118696 | 2017-03-21 | Drill / Deepen / Reopen | No Violations | Status check inspection on the well drilling process found H&P Drilling rig 608 on location with the 12.250 intermediate well bore total drilling measured depth recached at 9,147. The rig drilled the well bore in on fluid and will condition the hole before pulling the drill string and running a borehole deviation survey. Following that the rig will run the 9.625 casing and cement. |
2004764639 | 2017-02-19 | Casing String Witnessed | No Violations | I was on location to witness Stingray Cementing cement the 24 inch diameter casing into a 30 inch diameter bore hole. Pioneer drilled a 120 foot 30 inch diameter bore hole and set 120 feet of 24 inch diameter casing into the hole. Stingray Cementing ran 10 barrels of fresh water ahead of the cement. Stingray Cementing then ran 290 sacks of class A cement, 2% CaCL, and .25 parts per sack of floseal with 62 barrels of fresh water at 15.6 pounds and a yield of 1.2. Stingray Cementing then displaced with 57.7 barrels of fresh water until we got cement to surface. Stingray Cementing circulated about 15 barrels of cement to surface and finished cementing the casing into the bore hole. |
2012042136 | 2018-08-21 | Preliminary Restoration | No Violations | Preliminary Restoration status check inspection found the area affected by the well pad construction meets ORC 1509.072 with erosion control and vegetation established. The lease road and well pad is of stone construction and in good repair. The well pad perimeter is protected by an 8 chain link fence with signage posted at the entrance point. There are 5 wells present on the pad 3 Utica and 2 Marcellus. Each well is properly identified with signage. Fire extinguishers and emergency shut down devices are present at all critical location points on the well pad. Addressing the well - The well is equipped with a lower A and upper B section with a production flow cross present above the B section. The well is equipped with a production tree consisting of a manually operated primary master valve and a emergency shut down valve. Dual outlet flow line assemblies with production support monitoring and control devices are present on the production tree, the 2 flow lines join into one 4.5 diameter production sales line. Present on the well head A & B sections are 2 diameter riser pipes equipped with valves and gauges to monitor annular pressure. The A section gauge that measures the pressure between the 9.625 and 13.375 diameter casing strings shows 150 pounds per square inch (psi) pressure and the B section gauge which measures the pressure between the 5.5 and 9.625 diameter casing strings measures 180 pounds per square inch (psi) pressure. The 5.5 diameter production casing internal working pressure is 1,500 psi and the production flow line is 500 psi. Production equipment on site includes multiple line heaters a contact tower and glycol heater along with a gas compressor. The production fluid storage area consists of (10) steel construction 400 barrel fluid capacity tanks situated inside a polymer lined steel containment dike area with well and hazard identification present along with fire extinguishers and a emergency shut down control point. The company has also added |
2089487910 | 2018-08-21 | Production Wells | No Violations | Preliminary Restoration status check inspection found the area affected by the well pad construction meets ORC 1509.072 with erosion control and vegetation established. The lease road and well pad is of stone construction and in good repair. The well pad perimeter is protected by an 8 chain link fence with signage posted at the entrance point. There are 5 wells present on the pad 3 Utica and 2 Marcellus. Each well is properly identified with signage. Fire extinguishers and emergency shut down devices are present at all critical location points on the well pad. Addressing the well - The well is equipped with a lower A and upper B section with a production flow cross present above the B section. The well is equipped with a production tree consisting of a manually operated primary master valve and a emergency shut down valve. Dual outlet flow line assemblies with production support monitoring and control devices are present on the production tree, the 2 flow lines join into one 4.5 diameter production sales line. Present on the well head A & B sections are 2 diameter riser pipes equipped with valves and gauges to monitor annular pressure. The A section gauge that measures the pressure between the 9.625 and 13.375 diameter casing strings shows 180 pounds per square inch (psi) pressure and the B section gauge which measures the pressure between the 5.5 and 9.625 diameter casing strings measures 150 pounds per square inch (psi) pressure. The 5.5 diameter production casing internal working pressure is 1,500 psi and the production flow line is 500 psi. Production equipment on site includes multiple line heaters a contact tower and glycol heater along with a gas compressor. The production fluid storage area consists of (10) steel construction 400 barrel fluid capacity tanks situated inside a polymer lined steel containment dike area with well and hazard identification present along with fire extinguishers and a emergency shut down control point. The company has also added |
655868364 | 2017-10-3 0:00: | CT | No Violations | 0.50 |