X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-24725

Well Details

Well ID: 34-111-24725
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Lee Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001421
Farm/Lease Name: DAVID STALDER B
License Status: Producing
License Date: 2017-02-17
Spud Date: 2017-03-05
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2017-04-05
Well Total Depth: 19881.00 ft
Configuration: Horizontal
Latitude: 39.630000
Longitude: -80.940000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-02-17 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:2/17/2017, Expired Date:2/17/2019 12:00:00 PM, Drilling unit acres:686.418, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2017-03-10 UPDATE ACREAGE/DRILL UNIT PER PROPOSED PLAT-ALE
Reached Total Depth 2017-04-05
Correction to Well 2017-09-15 UPDATE TARGET/TALE/ACREAGE PER AS-DRILLED PLAT
Completion Report Received 2018-02-13
Record Last Modified 2018-02-22
Construction Permit Expires 2019-02-17

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-02-20 11391 11529 36
2018-02-20 19613 19718 3
19613 19718 3
11391 11529 36
11391 11529 36

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/17/2017 10/24/2017 10912 19,077,500.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 OILPERM A Halliburton Non-ionic Surfactant Listed Below Listed Below 0 0 0
HP-2814 OneAqua Friction Reducer Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 77.5146 141,809,000.0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.279123 510640
HP-2220 OneAqua Scale Inhibitor Listed Below Listed Below 0 0 0
Methanol 67-56-1 60 0.000109361 201
Ethanol 64-17-5 60 0.000128419 235
Non-hazardous food substance Proprietary 100 0.00001148 21
Heavy aromatic petroleum naphtha 64742-94-5 30 0.00006421 118
Poly(oxy-1,2-ethanediyl), alpha-(4-nonylphenyl)-omega-hydroxy-,

branched

127087-87-0 5 0.00001070 20
1,2,4 Trimethylbenzene 95-63-6 1 0.00000214 4
Crystalline silica, quartz 14808-60-7 100 11.7545 21,504,300.0
Sodium hydroxide 1310-73-2 4 0.000980337 1794
Phenol / formaldehyde resin 9003-35-4 5 0.0172583 31574
Oxyalkylated phenolic resin Proprietary 30 0.00008561 158
Distillates (petroleum,hydrotreated light) 64742-47-8 18 0.0117755 21543
Propargyl alcohol 107-19-7 10 0.00001823 34
Dazomet 533-74-4 24 0.00588202 10761
Ethoxylated alcohols Proprietary 30 0.00005468 101
Hydrochloric acid 7647-01-0 15 0.04187 76596
Ammonium persulfate 7727-54-0 95 0.00261719 4788
Acetic acid 64-19-7 60 0.000764034 1398
Hexamethylenetetramine 100-97-0 1 0.00345166 6315
Mullite 1302-93-8 100 0.345166 631462
Naphthalene 91-20-3 5 0.00001070 20
Ammonium chloride 12125-02-9 1.15 0.000752321 1377
Organic phosphate copolymer 71050-62-9 25 0.00328215 6005
Fatty acids, tall oil Proprietary 30 0.00005468 101
Olefins Proprietary 5 0.00002187 42
Acetic anhydride 108-24-7 100 0.00127339 2330
Modified thiourea polymer Proprietary 30 0.00005468 101
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
HP-9601 OneAqua Additive Listed Below Listed Below 0 0 0
PROP-RC CERAMIC-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
SAND-COMMON WHITE-100 MESH Halliburton Proppant Listed Below Listed Below 0 0 0
Produced Water Operator Base Fluid Water 7732-18-5 100 10.1026 18,482,200.0
MB-7530 OneAqua Biocide Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0
HAI-150E Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2017-10-16 H2O 15 443129 Gal 474190 Halliburton STAGE 45/45

STAGES 2-44 SEE IMAGES

2017-09-17 H2O 15 452671 Gal 485508 Halliburton STAGE 1/45

STAEGS 2-44 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 ECLIPSE RESOURCES I LP 91508 0 8
2018 ECLIPSE RESOURCES I LP 4131080 0 362
2019 ECLIPSE RESOURCES I LP 394195 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 ECLIPSE RESOURCES I LP Brine 4542 8
2018 ECLIPSE RESOURCES I LP Brine 74041 362
2019 ECLIPSE RESOURCES I LP Brine 4417 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1318004241 2017-3-10 0:00: DD No Violations 1.50
-1350044015 2017-3-9 0:00:0 DD No Violations 1.50
-1389549699 2020-8-18 0:00: PW No Violations 1.60
-2004764639 2017-2-19 0:00: CS No Violations 3.00
-2089487910 2018-8-21 0:00: PW No Violations 0.30
0655868364 2017-10-03 Completion Testing No Violations On the day of my inspection, I accompanied ODNR Engineer Technician Andrew Thomas. We were on location to examine a fluid release that occurred. Upon inspection, we found Halliburton on location completing the wells and S3 Pump Service running logging tools down hole. Also, we observed cleanup efforts for recent release. It was indicated that flange bolts broke on the high-pressure side of a pumping unit and released flowback fluid on containment and the pad surface. It was stated that the release contained approximately 40 barrels of flowback fluid. Contaminated materials are being dug up and stockpiled, then hauled from location in roll-off bins by Cowboy Industries. The materials will be taken to a facility to be tested. Containment liner beneath the frac trucks was ripped and indicated seepage to the pad surface. Small trenches are being dug to assist in the collection and removal of fluid. More environmental investigation may be needed to assess total impact to the pad surface and sub-surface. Bruce Carpenter was contacted by Andrew Thomas and explained the situation. Bruce said he would contact ODNR when they would do the investigation.
1318004241 2017-03-10 Drill / Deepen / Reopen No Violations
1350044015 2017-03-09 Drill / Deepen / Reopen No Violations
1488865933 2017-03-07 Casing String Witnessed No Violations On site inspection to witness the surface casing cement job arriving at 23:00 hours on 03/06/2017 to attend the safety meeting and witness the 13.375 surface casing cement job with H&P Drilling rig 608 on location along with Schlumberger Cement service contractors. Upon arrival I was informed the rig was unable to land the last 2 casing joints due to hole conditions and would lay one casing joint down and load the hole with fresh water and circulate the last joint in the hole. The rig had drilled the 17.5 diameter production borehole to a measured depth of 1,872 and ran a 13.375 split weight casing string with 547.8 of 61 lb/ft J-55 grade casing on the bottom of the string and 1,231.31 of 54.5 lb/ft J-55 buttress thread on the upper section of the string with a total of 1,777.11 of 13.375 casing ran with a float shoe and float collar casing equipment ran. At 4:45 am on 03/07/17 the casing was landed, the cement head installed and the safety meeting held. The cement job was began at 5:00 am by pumping 20 barrels of 6% gel spacer followed by 320 barrels cement consisting of 1,485 sacks of class A cement. The cement was displaced with 267 barrels of fresh water and the casing was pressure tested to 500 psi over cement displacement pressure upon the landing of the cement plug in the float collar. Cement returns were witnessed to surface.
1490118696 2017-03-21 Drill / Deepen / Reopen No Violations Status check inspection on the well drilling process found H&P Drilling rig 608 on location with the 12.250 intermediate well bore total drilling measured depth recached at 9,147. The rig drilled the well bore in on fluid and will condition the hole before pulling the drill string and running a borehole deviation survey. Following that the rig will run the 9.625 casing and cement.
2004764639 2017-02-19 Casing String Witnessed No Violations I was on location to witness Stingray Cementing cement the 24 inch diameter casing into a 30 inch diameter bore hole. Pioneer drilled a 120 foot 30 inch diameter bore hole and set 120 feet of 24 inch diameter casing into the hole. Stingray Cementing ran 10 barrels of fresh water ahead of the cement. Stingray Cementing then ran 290 sacks of class A cement, 2% CaCL, and .25 parts per sack of floseal with 62 barrels of fresh water at 15.6 pounds and a yield of 1.2. Stingray Cementing then displaced with 57.7 barrels of fresh water until we got cement to surface. Stingray Cementing circulated about 15 barrels of cement to surface and finished cementing the casing into the bore hole.
2012042136 2018-08-21 Preliminary Restoration No Violations Preliminary Restoration status check inspection found the area affected by the well pad construction meets ORC 1509.072 with erosion control and vegetation established. The lease road and well pad is of stone construction and in good repair. The well pad perimeter is protected by an 8 chain link fence with signage posted at the entrance point. There are 5 wells present on the pad 3 Utica and 2 Marcellus. Each well is properly identified with signage. Fire extinguishers and emergency shut down devices are present at all critical location points on the well pad. Addressing the well - The well is equipped with a lower A and upper B section with a production flow cross present above the B section. The well is equipped with a production tree consisting of a manually operated primary master valve and a emergency shut down valve. Dual outlet flow line assemblies with production support monitoring and control devices are present on the production tree, the 2 flow lines join into one 4.5 diameter production sales line. Present on the well head A & B sections are 2 diameter riser pipes equipped with valves and gauges to monitor annular pressure. The A section gauge that measures the pressure between the 9.625 and 13.375 diameter casing strings shows 150 pounds per square inch (psi) pressure and the B section gauge which measures the pressure between the 5.5 and 9.625 diameter casing strings measures 180 pounds per square inch (psi) pressure. The 5.5 diameter production casing internal working pressure is 1,500 psi and the production flow line is 500 psi. Production equipment on site includes multiple line heaters a contact tower and glycol heater along with a gas compressor. The production fluid storage area consists of (10) steel construction 400 barrel fluid capacity tanks situated inside a polymer lined steel containment dike area with well and hazard identification present along with fire extinguishers and a emergency shut down control point. The company has also added
2089487910 2018-08-21 Production Wells No Violations Preliminary Restoration status check inspection found the area affected by the well pad construction meets ORC 1509.072 with erosion control and vegetation established. The lease road and well pad is of stone construction and in good repair. The well pad perimeter is protected by an 8 chain link fence with signage posted at the entrance point. There are 5 wells present on the pad 3 Utica and 2 Marcellus. Each well is properly identified with signage. Fire extinguishers and emergency shut down devices are present at all critical location points on the well pad. Addressing the well - The well is equipped with a lower A and upper B section with a production flow cross present above the B section. The well is equipped with a production tree consisting of a manually operated primary master valve and a emergency shut down valve. Dual outlet flow line assemblies with production support monitoring and control devices are present on the production tree, the 2 flow lines join into one 4.5 diameter production sales line. Present on the well head A & B sections are 2 diameter riser pipes equipped with valves and gauges to monitor annular pressure. The A section gauge that measures the pressure between the 9.625 and 13.375 diameter casing strings shows 180 pounds per square inch (psi) pressure and the B section gauge which measures the pressure between the 5.5 and 9.625 diameter casing strings measures 150 pounds per square inch (psi) pressure. The 5.5 diameter production casing internal working pressure is 1,500 psi and the production flow line is 500 psi. Production equipment on site includes multiple line heaters a contact tower and glycol heater along with a gas compressor. The production fluid storage area consists of (10) steel construction 400 barrel fluid capacity tanks situated inside a polymer lined steel containment dike area with well and hazard identification present along with fire extinguishers and a emergency shut down control point. The company has also added
655868364 2017-10-3 0:00: CT No Violations 0.50

For data sources see[10]

References