X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-61146

Well Details

Well ID: 34-111-61146
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Center Township
Operator Name: DC OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: L B GRIFFITH-HAMILTON
License Status: Final Restoration
License Date: 2017-04-21
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.700000
Longitude: -81.090000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-04-21 Proposed Formations:KEENER, Issued Date:4/21/2017, Expired Date:4/21/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-06-07 UPDATED LOCATION PER SURVEYOR COORDINATES-ALE 05/09/17.
Record Last Modified 2017-10-20 UPDATED LOCATION PER SURVEYOR COORDINATES-ALE 05/09/17.
Construction Permit Expires 2019-04-21 UPDATED LOCATION PER SURVEYOR COORDINATES-ALE 05/09/17.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 DC OIL & GAS LLC 0.00 68.00 315
1995 DC OIL & GAS LLC 0.00 108.00 315
1996 DC OIL & GAS LLC 0.00 105.00 316
1997 DC OIL & GAS LLC 0.00 108.00 220
1998 DC OIL & GAS LLC 0.00 52.00 225
1999 DC OIL & GAS LLC 0.00 62.00 230
2000 DC OIL & GAS LLC 0.00 55.00 365
2001 DC OIL & GAS LLC 0.00 23.00 200
2002 DC OIL & GAS LLC 0.00 60.00 300
2003 DC OIL & GAS LLC 0.00 0.00 30
2004 DC OIL & GAS LLC 0.00 0.00 0
2005 DC OIL & GAS LLC 0.00 0.00 50
2006 DC OIL & GAS LLC 0.00 17.00 100
2007 DC OIL & GAS LLC 0.00 0.00 0
2008 DC OIL & GAS LLC 0.00 32.00 300
2009 DC OIL & GAS LLC 0.00 16.00 300
2010 DC OIL & GAS LLC 0.00 45.00 300
2011 DC OIL & GAS LLC 0.00 50.00 300
2012 DC OIL & GAS LLC 0.00 74.00 300
2013 DC OIL & GAS LLC 0.00 93.00 365
2014 DC OIL & GAS LLC 0.00 76.00 200
2015 DC OIL & GAS LLC 0.00 30.00 200
2016 DC OIL & GAS LLC 0.00 46.00 200
2017 DC OIL & GAS LLC 0.00 55.00 60

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 DC OIL & GAS LLC Brine 0 315
1995 DC OIL & GAS LLC Brine 0 315
1996 DC OIL & GAS LLC Brine 0 316
1997 DC OIL & GAS LLC Brine 0 220
1998 DC OIL & GAS LLC Brine 0 225
1999 DC OIL & GAS LLC Brine 0 230
2000 DC OIL & GAS LLC Brine 0 365
2001 DC OIL & GAS LLC Brine 0 200
2002 DC OIL & GAS LLC Brine 0 300
2003 DC OIL & GAS LLC Brine 0 30
2004 DC OIL & GAS LLC Brine 0 0
2005 DC OIL & GAS LLC Brine 0 50
2006 DC OIL & GAS LLC Brine 0 100
2007 DC OIL & GAS LLC Brine 0 0
2008 DC OIL & GAS LLC Brine 0 300
2009 DC OIL & GAS LLC Brine 0 300
2010 DC OIL & GAS LLC Brine 0 300
2011 DC OIL & GAS LLC Brine 0 300
2012 DC OIL & GAS LLC Brine 0 300
2013 DC OIL & GAS LLC Brine 0 365
2014 DC OIL & GAS LLC Brine 3 200
2015 DC OIL & GAS LLC Brine 0 200
2016 DC OIL & GAS LLC Brine 0 200
2017 DC OIL & GAS LLC Brine 7 60

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-136706472 2017-8-10 0:00: FR No Violations 0.50
-141762844 2015-9-23 0:00: PW No Violations 1.50
-1421239189 2017-6-7 0:00:0 PB No Violations 6.50
-930578040 2015-9-21 0:00: PW No Violations 3.00
0136706472 2017-08-10 Final Restoration No Violations Final restoration status check inspection found the well site meets ORC 1509.072 with vegetation established and all equipment removed from location. The well owner is using the tank battery for other wells on the lease. No pit was excavated during the plugging process.
0141762844 2015-09-23 Production Wells No Violations Compliance Notice # 1442428974 and Complaint # 5126 follow up inspection. On this day I observed the area affected by the fluid discharge from the knock out separator has been remediated with lime -grass seed and straw being put down after an excavator was brought in and the area was dressed up. A new tank battery is being built and a fluid recovery tank is being set. A total of 3- 100 barrel tanks are present in the new dike along with a 1600 gallon plastic tank. The dike is shared with 3411161153-0000 & 3411161109-0000. The violation was resolved on this day.
0930578040 2015-09-21 Production Wells No Violations Compliance Notice # 1442428974 and Complaint # 5126 follow up inspection. On this day I witnessed contractors remediating the affected area. Lime was also used. Upon final grading stew and grass seed will be put down. The neighboring landowner stopped by and indicated he moved into the area in 1958 and the affected area was present at that time.
1421239189 2017-06-07 Plug / Plug Back No Violations On site inspection to witness the well plugging process with a Service Rig owned by Chuck Dye and Formation Cementing. The rig has pulled the 2 tubing and rods out of the hole and ran in and tagged bottom at 1,588. The only casing present at surface is 6.625 set to a unknown depth and the well bore is a shot hole completion. The 2 diameter tubing was then ran back in the hole to a measured depth of 1,567. Formation Cementing pumped a 21.5 barrel bottom plug into the shot hole with 10 barrels of gel pumped ahead. The plug consisted of 100 sacks of class A cement and 1% calcium chloride and 50 pounds of loss circulation material. The plug was displaced to 1,250 with 3.7 barrels of fresh water. The tubing was then pulled up to 1,250 and a 11 barrel plug set from 1,250 to 950 to isolate the bottom of the 6.625 historically set to ground level elevation 1,106 plus 100 to isolate the red rock formations. In attempt to prepare to set the surface plug the well was circulated with the borehole taking 20 barrels to load and then being on a vacuum sot he 2 was pulled and the last plug was tagged with the rig wireline at 1,146and the fresh water fluid level marked at 190, the casing appears to have holes in it at the upper coal seam around 450 so a bridge was built in the well bore at 550 and the 2 tubing ran back into the well bore to 540 and 16.1 barrel class A surface plug then set from 540 to surface with the well circulating and cement returns to surface, the 2 tubing was pulled out of the hole and the well topped off to 30 below grade. The cement stayed up to surface and did not fall back.
1442428974 2015-09-16 Production Wells Violations Noted On this day I received a complaint from Phil Keevert with the Monroe County EMA who indicated His office had received information regarding pollution & contamination from a oil well tank battery off of SR 800 South of Woodsfield. Upon arrival the following equipment was noted at the well head 6.250 casing-2 production tubing and pumping rods with the production valves open and the well set up to be produced by the means of a pumping unit. At the production fluid storage area a single 100 barrel tank is present inside of a established dike area with a fluid separator present on top of the tank. Addressing the complaint, It was observed that a 1.250 discharge line was running from the fluid separator over the hill to point of EPE 20 -39.70403 X 81.09387, at this point the line was found to be open to the atmosphere with visible signs of all vegetation including trees to be stressed. Measurements were taken to a point of 207 below the impact point to a wet weather stream be where at 13:55 pm a small puddle of standing fluid was Titrate tested for chlorides with the reading exceeding a low level strip test of 611 parts per million and reading 4,300 parts per million on a high range strip test. The well owner Dean Christman was notified by phone with the following directions. Stop surface discharge and remediate the affected area. Relocate the production tank back at least 50 from the traveled portion of the roadway. The owner has been given 10 days to comply.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1442428974 US-OH-112861 2015-11-23 Well operation causing pollution and contamination
1442428974 US-OH-112862 2015-11-23 Improperly located oil tank
1442428974 US-OH-112863 2016-07-26 NONE5 Failure to meet well and/or tank battery setbacks from a railroad or roads

For data sources see[7]

References