Well Details

Well ID: 34-111-61169
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Center Township
Operator Name: VIRCO INC
Well Pad ID:
Farm/Lease Name: KING R A
License Status: Final Restoration
License Date: 2014-08-26
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.700000
Longitude: -81.090000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Change of Owner 2011-09-12 Operator changed from 5090, BROUGHTON BROTHERS INC to 7434, VIRCO INC
Change of Owner 2011-09-12 Operator changed from 9998, HISTORIC OWNER to 5090, BROUGHTON BROTHERS INC
APP 2014-08-26 Proposed Formations:KEENER SANDSTONE, Issued Date:8/26/2014, Expired Date:8/25/2016 12:00:00 PM, Drilling unit acres:72, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-11-06
Construction Permit Expires 2016-08-25
Record Last Modified 2017-02-10

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 VIRCO INC 285.00 0.00 210
2012 VIRCO INC 444.00 0.00 366
2014 VIRCO INC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 VIRCO INC Brine 0 210
2012 VIRCO INC Brine 0 366
2014 VIRCO INC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1394555160 2014-03-11 Production Wells Violations Noted Status check inspection per request of the landowner found the following equipment present at the well head-6.625 casing-2 tubing and pumping rods and a .750 vent packer tubing string with no pumping unit present and no flow lines or valves present or well identification, no tank battery or gas metering equipment was found related to the said well. Instructions are as follows- plug the said well within 180 days. ODNR Monroe Co Inspector Bill Stolarik 740-507-6592.
1400075635 2014-05-14 Administrative Inspection No Violations Compliance notice # 1394555160 administrative inspection to document my conversation at 9:50 am on this day with Rocky Roberts with Triad Hunter who now has controlling interest in Virco Inc, Triad has not received the violation and the Virco post office box is no longer valid, A copy of the violation was sent by e-mail to Mr. Roberts and they shall be updating the Virco address with the Division.
1405902293 2014-07-20 Administrative Inspection No Violations Compliance Notice # 1394555160 to document on 07/15/14 Ben Smeltzer with Virco contacted me by phone and I provided him with the database well card completion records verbally indicating the well was completed to the Kenner sand formation, Mr.Smeltzer is working on submitting a plugging permit on the said well.
1411994769 2014-09-29 Administrative Inspection No Violations Compliance notice administrative inspection to follow up on the violation issued on 03-12-14. Ben Smeltzer with Triad has contacted me and will be moving a rig in to plug the said well in the near future, a plugging permit has been received.
1415213807 2014-11-04 Plug / Plug Back No Violations On 11/03/14 Vircos company rig move into location and began pulling the 2 tubing. On 11/04/14- A total of 1,540 of 2 tubing was pulled out of the hole with a gas escape packer set at a depth of 1,090 indicating the well was producing from the Keener formation.
1415229227 2014-11-05 Plug / Plug Back No Violations On 11/05/14 Appalachian wire line services ran in the hole with a casing collar locater and marked the bottom of the 6.625 @ 1,260 and then shot 4 perforations in the 6.625 @ 200 to 201 to seal the surface water strata during the cementing process. Tubing was ran back in and the hole had bridged off at 1040 and a 75 sack plug was set covering up to 590. The plug was allowed to set and tagged at 995 indicating the plug slid down hole to TD A second 200 plug was set on top of the 1st plug. The tubing was then pulled up to 378 and the surface plug set with good circulation but no cement to surface with 109 sacks of class A cement used with 25# of flake and cotton seed hulls for LCM. The company shall pull the tubing on this day and tag the cement tomorrow and top off the surface accordingly. I was on site to witness all the events on this day.
1465571988 2016-06-08 Final Restoration No Violations The well site restoration meets ORC 1509.072.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1394555160 US-OH-111669 2014-11-20 Failure to legibly identify well
1394555160 US-OH-111670 2014-11-20 Well shall be plugged

For data sources see[7]