34-111-64034

Well Details

Well ID: 34-111-64034
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Franklin Township
Operator Name: YONTZ OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: ANDERSON FRED
License Status: Producing
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.750000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Change of Owner 2011-03-17 Operator changed from 9998, HISTORIC OWNER to 2356, YONTZ OIL & GAS JAMES. WELL TRANSFERRED PER OWNERSHIP AFFIDAVIT. SEE OWNER FILE FOR MORE INFO.
Change of Owner 2018-06-12 Operator changed from 2356, YONTZ JAMES to 10153, YONTZ OIL & GAS LLC
Record Last Modified 2018-06-12

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 YONTZ JAMES 0.00 5.00 365
2011 YONTZ JAMES 0.00 21.00 365
2012 YONTZ JAMES 0.00 16.00 366
2013 YONTZ JAMES 0.00 17.00 365
2015 YONTZ JAMES 0.00 15.00 365
2016 YONTZ JAMES 0.00 14.00 365
2017 YONTZ JAMES 0.00 10.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 YONTZ JAMES Brine 0 365
2011 YONTZ JAMES Brine 37 365
2012 YONTZ JAMES Brine 20 366
2013 YONTZ JAMES Brine 0 365
2015 YONTZ JAMES Brine 5 365
2016 YONTZ JAMES Brine 10 365
2017 YONTZ JAMES Brine 15 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1279992801 2017-3-29 0:00: PW No Violations 0.70
-1397258777 2019-6-19 0:00: PW No Violations 0.70
-265200532 2020-1-9 0:00:0 PW No Violations 0.50
0132261042 2018-09-18 Production Wells No Violations Status check follow up inspection to a complaint # 5968 filed by a local landowner Mike Gardner who indicated the flow lines from the well had been ran to a well on his property without his permission or consent. Upon inspection the well was observed to be equipped with 6.625 diameter production casign and 2 diameter production tubing with both a tubing and casing well head present.There is no flow line attached to the casing well head section, a valve is present in the open position. There is a 1 valve and flow line attached to the tubing well head. The well is set up to be produced by the means of a pumping unit driven by a gasoline engine however vegetaion has grown up inside the motor pullies and belt system. At the production fluid storage facility 2 steel construction storage tanks are present inside a earthen dike with well identification visible however dense vegetation restricts access to the tank battery area. No sign of recent human activity is present at the well or tank battery area.
0752871779 2018-04-09 Production Wells No Violations Status check inspection found the well equipped with a 6.625 diameter production casing with a casing well head installed on the 6.625 casing and 2 diameter production tubing inserted into the casing. The well head also consists of a 2 tubing string and well head with pumping rods inserted into the tubing. No casing production flow line is attached and a 1 flow line is attached to the tubing well head with a production valve present in the open position. The production facility consists of (2) steel design production tanks not of common dimensional size. Sitting atop the larger of the two tanks is a gravity fluid separator with a 3 plastic corrugated discharge line that has been installed from the separator and into the earths surface inside the dike and leads to a discharge point down elevation from the production facility where a 3 corrugated line was observed and photographed to be present and open ended. There is dense vegetation at both the production facility and the well head as in my previous inspections. No sign of recent activity is present at the well head or production facility. Production is current up until 2016.
1279992801 2017-03-29 Production Wells No Violations Status check inspection found the well was observed to be equipped with 6.625 diameter production casing and 2 diameter production tubing. There is a 1 plastic sales line hooked to the tubing head and no production line hooked the casing head. At the production fluid storage facility 2 steel tanks are present one being of approximate 70 barrels and the other being of approximate 50 barrels capacity. There is also a 3rd tank in the area that is not in service located at Epe 9-39.75679 x 81.27123and is approximately 80 barrels capacity, the bottom seam of the tank is leaking and will need removed off location.
132261042 2018-9-18 0:00: PW No Violations 0.40
1600646286 2019-02-27 Production Wells No Violations On site inspection as a follow up to complaint 5968 filed by the landowner Mike Gardner on . The initial complaint indicated there were (2) wells on the landowners property in Franklin Township Monroe County identified as the Hogue Mason # 1 and # 2 well. The landowner also indicated a well on a neighboring property that is situated in Summit Township of Monroe County is also producing into the production facility on his property without his consent. The landowners initial concerns were directed to the question of how proper production was being recorded and reported when wells on 2 separate leases were produced into the same common tanks. Also indicated in the complaint was that production water from both tanks was being discharged onto his property and he wished the discharge to cease. I have visited the lease 5 times since 03/29/2017 and have found no indication that the wells have been produced from that date to current day. The wells have became increasingly engulfed in vegetation since my first visit. The said well is equipped with 6.625 production casing and 2.375 diameter production tubing with both casing and tubing well heads present. The casing head is equipped with a 2 diameter valve attached to the well head, the valve is in the closed position and no flow line is present. The tubing head has a valve present and the flow line is connected at the well head. The well is set up to be produced by the means of a gasoline powered pumping unit. The production facility consists of 2 steel tanks that are not of common size and appear to be 50 and 80 barrel approximated size capacity. Both tanks are equipped with gravity fluid separators with 3 corrugated discharges that are constructed to allow product to discharge inside the dike area. There is a earthen dike constructed around the production tanks and ID posted on the tank battery only. There is dense vegetation present around the well head and pumping unit along with the production storage facility. I did
414894960 2019-8-8 0:00:0 PW No Violations 0.50
53513816 2020-1-9 0:00:0 PW No Violations 0.50
565692762 2020-7-9 0:00:0 PW No Violations 0.50
752871779 2018-4-9 0:00:0 PW No Violations 0.50

For data sources see[7]