34-111-65466

Well Details

Well ID: 34-111-65466
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Wayne Township
Operator Name: CISLER OIL AND GAS
Well Pad ID:
Farm/Lease Name: SLOAN SARAH E
License Status: Producing
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.720000
Longitude: -81.180000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Change of Owner 2008-01-22 Operator changed from 5702, KRISHER EARLEY DRLG PTNSP to 5719, CISLER OIL AND GAS
Record Last Modified 2018-02-12 NO RECORD. UPDATE LOCATION PER BILL STOLARIK-ALE 06/28/2016. UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 CISLER OIL AND GAS 0.00 60.00 300
2013 CISLER OIL AND GAS 0.00 60.00 0
2014 CISLER OIL AND GAS 0.00 0.00 0
2016 CISLER OIL AND GAS 0.00 0.00 0
2017 CISLER OIL AND GAS 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 CISLER OIL AND GAS Brine 0 300
2013 CISLER OIL AND GAS Brine 0 0
2014 CISLER OIL AND GAS Brine 0 0
2016 CISLER OIL AND GAS Brine 0 0
2017 CISLER OIL AND GAS Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1053214225 2019-6-19 0:00: PW No Violations 0.50
0692919286 2017-12-15 Production Wells No Violations On this day, I accompanied ODNR Inspector William Stolarik. Please refer to his comments for a detailed report. I am conducting a follow-up inspection on Chiefs Order 2017-101. I found the well equipped with casing, tubing, and a pumping unit. The tubing has a flowline attached with the valve closed. There is also (1) 100 barrel steel tank within an earthen dike. There is proper identification. Pictures were taken during inspection.
0840081800 2017-12-15 Production Wells No Violations Order 2017-101 follow up inspection found the well equipped with production casing tubing and pumping rods with the well set up to be produced by the means of a pumping unit. There is no valve or flow line attached to the casing well head and a 1 flow line attached to the tubing well head with no production valve present. The flow line leads to a nearby 100 barrel production tank. Proper well identification is present. On this day I spoke with Scott Cisler who indicated due to financial troubles He was not able to secure insurance. I referenced the order language to Mr. Cisler and indicated the Order language required production to be suspended.
1275841449 2005-02-17 Production Wells No Violations Upon inspecting well site found well to be capable of producing no violations noted .

Well is equipped with pumpjack with motor tubing and rods in place,production tank in need of I.D.

1426497858 2015-03-15 Production Wells Violations Noted On site status check inspection of the well head found the following equipment present 6.625 casing 2 tubing and pumping rods with the well standing idle both commercially and domestically. A single 100 barrel tank is located on location near the well head with visible oil product located inside the dike area where the tank is leaking. ODNR -RBDMS records show no reported production in the database. Instructions are as follows- Recover the standing fluid from within the dike and empty the oil tank immediately-Plug the said well within 180 days. ODNR Monroe County Inspector Bill Stolarik 740-507-6592.
1443034391 2015-09-23 Production Wells No Violations Compliance notice # 1426497858 follow up inspection found the well has had repairs made and is now capable of production. A single 100 barrel tank is present near the well head with proper well identification posted. The violation was resolved on this day.
1612996516 2017-11-13 Production Wells No Violations Status check inspection found the well equipped with 6.625 diameter production casing and 2 diameter production tubing with a tubing head present and a production flow line attached to the tubing head with the production valve in the open position. There is no casing line attached and the well is set up to be produced by the means of a pumping unit driven by the means of an electric motor with an electric service present that has an active service meter. On location near the well head is the production fluid storage area consisting of a 100 barrel steel production tank and 250 gallon plastic brine tank, both tanks are located inside a earthen dike containment area with well identification present. No commercial production has been reported since 2014.
692919286 2017-12-15 0:00 PW No Violations 0.50
840081800 2017-12-15 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1426497858 US-OH-112425 2015-11-23 Well shall be plugged
1426497858 US-OH-112426 2015-11-23 Use of pit of dike for ultimate disposal of brine or other wastes

For data sources see[7]