34-111-65677

Well Details

Well ID: 34-111-65677
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Perry Township
Operator Name: RINARD PETROLEUM LLC
Well Pad ID:
Farm/Lease Name: CHRISTMAN HARRY(BEAVER BUCHANAN)
License Status: Producing
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.640000
Longitude: -81.040000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2005-11-30 INSPECTED BY DAVE BALL ON NOVEMBER 14, 2005. WELL LOCATED INSIDE OF A SMALL METAL BUILDING WITH HORSEHEAD PUMPING UNIT. LANDOWNER IS PRODUCING WELL; 1 50 BARREL TANK.
Change of Owner 2010-08-16 Operator changed from 9997, UNREGISTERED OWNER to 8688, AUGERHEAD OIL LLC
Change of Owner 2013-05-20 Operator changed from 8688, AUGERHEAD OIL LLC to 9086, GENESIS RESOURCES LLC
Change of Owner 2018-06-20 Operator changed from 9086, GENESIS RESOURCES LLC to 10087, RINARD PETROLEUM LLC
Record Last Modified 2018-06-20 INSPECTED BY DAVE BALL ON NOVEMBER 14, 2005. WELL LOCATED INSIDE OF A SMALL METAL BUILDING WITH HORSEHEAD PUMPING UNIT. LANDOWNER IS PRODUCING WELL; 1 50 BARREL TANK.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 AUGERHEAD OIL LLC 20.00 33.00 365
2011 AUGERHEAD OIL LLC 25.00 31.00 365
2012 AUGERHEAD OIL LLC 25.00 25.00 366
2013 AUGERHEAD OIL LLC 25.00 23.00 135
2014 GENESIS RESOURCES LLC 0.00 45.00 365
2015 GENESIS RESOURCES LLC 0.00 39.00 365
2016 GENESIS RESOURCES LLC 0.00 34.00 312
2017 GENESIS RESOURCES LLC 0.00 41.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 AUGERHEAD OIL LLC Brine 0 365
2011 AUGERHEAD OIL LLC Brine 365
2012 AUGERHEAD OIL LLC Brine 0 366
2013 AUGERHEAD OIL LLC Brine 0 135
2014 GENESIS RESOURCES LLC Brine 0 365
2015 GENESIS RESOURCES LLC Brine 50 365
2016 GENESIS RESOURCES LLC Brine 286 312
2017 GENESIS RESOURCES LLC Brine 329 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1394131115 2014-03-06 Production Wells No Violations Status check inspection found the following equipment present at the well head 6.625 casing-2 tubing and rods with the production valves open and the well being produced by the means of a pumping unit, A single 100 barrel production tank is present in an established dike area.
1431519339 2015-05-13 Production Wells Violations Noted Status check inspection found the following present at the well head 6.625 casing 2 production tubing with a 1 vent packer string with the production valves in the open position. A single 100 barrel production tank is present in an established dike. It was also observed that a fluid knock out separator is present on top of the production tank with a 1 discharge line exiting the dike and leading to a point in a defined wet weather ditchline at a know point of EPE 9 -39.64416 X 81.04945 in which it was observed that a brine scald was present along with stressed vegetation and salt mineral deposits. At 8:39 am the affected inside the ditch line area was photographed and standing fluid was tested for chlorides using both High and Low range Quantab field strip tests with reading exceeding the low level tests at 611 and parts per million and the high level tests at 6,171 parts per million with the tests being administered at a point of; EPE 9-39.64397 X 81.04966. Also noted was a Ohio Oil Gathering run ticket on the tank battery from 04/30/2015 indicating a total of 40 barrels of crude oil was shipped out with the producer name identified as Genesis Resources LLC. Instructions are as follows; Stop the surface discharge of production fluid and remediate the affected area-Post proper well identification in a conspicuous place. ODNR Monroe County Inspector Bill Stolarik 740-507-6592.
1434467802 2015-06-16 Production Wells No Violations Compliance Notice # 1434467802 follow up inspection. Upon inspection on this day it was observed that the producer has set a 1,200 gallon capacity plastic tank inside the dike area to recover the fluid created from the knock out separator. The company has also made an attempt to remediate the affected area. Proper well identification has been posted.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1431519339 US-OH-112609 2015-06-22 Well operation causing pollution and contamination
1431519339 US-OH-112610 2015-06-22 Failure to legibly identify well

For data sources see[7]

References