34-111-65708

Well Details

Well ID: 34-111-65708
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Washington Township
Operator Name: ARMSTRONG ROBERT D
Well Pad ID:
Farm/Lease Name: WINLAND
License Status: Producing
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth: 1786.00 ft
Configuration: Vertical
Latitude: 39.620000
Longitude: -81.210000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2008-02-26 WELL INSPECTED BY PAT SHREVE ON 2/5/2008. OLD EXEMPT MISSISSIPPIAN WELL OF BEREA SANDSTONE. WELL WAS DRILLED IN 1913 TO A DEPTH OF 1786'. WELL HAS PUMP JACK.
Record Last Modified 2013-10-03 WELL INSPECTED BY PAT SHREVE ON 2/5/2008. OLD EXEMPT MISSISSIPPIAN WELL OF BEREA SANDSTONE. WELL WAS DRILLED IN 1913 TO A DEPTH OF 1786'. WELL HAS PUMP JACK.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 ARMSTRONG ROBERT D 0.00 85.00 365
2017 ARMSTRONG ROBERT D 0.00 70.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 ARMSTRONG ROBERT D Brine 0 365
2017 ARMSTRONG ROBERT D Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1323268911 2011-12-05 Production Wells No Violations On day of inspection well was complete with pump jack. Tank batter contents included: one 110 bbl oil storage, 50 bbl brine tank, and a gravity separator. No violations noted.
1361815341 2013-02-25 Production Wells Violations Noted Inspection of the tank battery found a 100 barrel tank with a 55gallon oil-water knock out separator on top and a 50 barrel tank all located in a enclosed dike that has obvious signs of pollution and contamination in the bottom of the dike from where the knock out separator has backed up and overflowed. Instructions are as follows Clean up all oil and contaminated soils removing soil to an EPA approved landfill; stop dispersant of production waste water outside of the tank battery and have the production waste water hauled to a disposal well. Post proper legible identification. Properly register all producing wells on the lease with the Division.
1362419640 2013-03-04 Production Wells No Violations Compliance agreement follow up inspection found the pollution and contamination inside the tank battery has been cleaned up and the dike area remediated. Inspection of the well head found the following equipment present-6.625 casing -2 tubing and pumping rods with a .750 vent packer string with the well only capable of supplying gas at the time of my inspection due to the means of motive power missing from the pumping unit and the tubing valve closed. A 100 barrel production tank is present in the tank battery. Inspector did receive notification from Rob Armstrong this morning stating that the oil has been cleaned up, Rob also stated that the well did not belong to Him that it belonged to His son. I informed Rob Armstrong that the Database indicated He was the owner as well as the identification on the tank battery and that He would have to speak with the Divisions Registration Dept.
550864453 2020-5-20 0:00: PW No Violations 0.30

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1361815341 US-OH-110533 2013-02-25 Well operation causing pollution and contamination
1361815341 US-OH-110534 2013-02-25 No SPCC dike/or failure to keep dike free of water or oil
1361815341 US-OH-110535 2013-02-25 Unlawful method of storage or disposal of brine or other wastes

For data sources see[7]