If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-21716 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.74,"lon":-81.83,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: Bloom Township | |
Operator Name: AOCSWD LLC | |
Well Pad ID: | |
Farm/Lease Name: MAUTZ ELOISE | |
License Status: Active Injection | |
License Date: 1983-08-17 | |
Spud Date: 1983-08-27 | |
Spud Drilling Contractor: ROSS WELL SERVICE | |
Final Drill Date: 1983-08-27 | |
Well Total Depth: 4851.00 ft | |
Configuration: Vertical | |
Latitude: 39.740000 | |
Longitude: -81.830000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-06-10 | 6 BENATTY CORP GeoDate 6/10/82 |
Unknown | 1982-06-10 | Issued Date 6/10/82 Expired Date 12/1/82 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
CO | 1983-08-17 | 1694 MATT WELL SERVICE INC GeoDate 8/17/83 |
Enhanced Recovery | 1983-08-17 | Issued Date 8/17/83 Expired Date 2/13/84 Acres 0040000 Tool Type NT Proposed Formation CLINTON Proposed Depth 04851 Proposed Drill Depth 04851 |
Completed | 1983-08-27 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Original Spud | 1983-08-27 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Reached Total Depth | 1983-08-27 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Completion Report Received | 1983-08-29 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Construction Permit Expires | 1984-02-13 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
CO | 1991-09-16 | 2111 BUFFALO OILFIELD SER INC GeoDate 8/17/83 |
CO | 1994-09-30 | 1694 MATT WELL SERVICE INC |
CO | 1994-09-30 | 4930 CANTON OIL & GAS COMPANY GeoDate 8/17/83 |
Annulus Pressure Monitoring Approved | 1997-08-12 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Change of Owner | 2004-07-14 | Operator changed from 4930, CANTON OIL & GAS COMPANY to 7666, ARVILLA OILFIELD SERVICES LLC |
Change of Owner | 2011-03-18 | Operator changed from 7666, ARVILLA OILFIELD SERVICES LLC to 8690, SES ASSETS LLC |
Last Compliance Report | 2013-04-30 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
Change of Owner | 2014-10-02 | Operator changed from 8690, SELECT ENERGY SERVICES LLC to 9350, AOCSWD LLC |
Record Last Modified | 2017-02-15 | DRILLED BY JEB DRLG AND HALLIBURTON CONVERT 8-20-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-03-15 | 4676 | 4686 | 16 |
4676 | 4686 | 16 | |
4676 | 4686 | 16 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | FRAC WITH 1880 BBLS OF H2O AND 58,400# SAND | |||
H2O | 0 | 1880 Bbl | 58400 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1989 | GLENEAYRE RESOURCES INC | 596.00 | 0.00 | 365 |
1990 | GLENEAYRE RESOURCES INC | 0.00 | 0.00 | 0 |
2016 | ARTEX OIL COMPANY | 0.00 | 541.00 | 365 |
2017 | ARTEX OIL COMPANY | 0.00 | 309.00 | 365 |
2018 | AOCSWD LLC | 0.00 | 195.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1989 | GLENEAYRE RESOURCES INC | Brine | 0 | 365 |
1990 | GLENEAYRE RESOURCES INC | Brine | 0 | 0 |
2016 | ARTEX OIL COMPANY | Brine | 495 | 365 |
2017 | ARTEX OIL COMPANY | Brine | 0 | 365 |
2018 | AOCSWD LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-103050284 | 2006-9-18 0:00: | ER | No Violations | |
-1034064802 | 2015-5-13 0:00: | ER | No Violations | |
-1048739582 | 2003-8-13 0:00: | SW | No Violations | 1.50 |
-1066244817 | 2008-8-28 0:00: | ER | No Violations | |
-1075332448 | 2013-4-29 0:00: | ER | No Violations | |
-1096057023 | 2004-11-30 0:00 | ER | No Violations | |
-1102724236 | 2004-10-27 0:00 | ER | No Violations | |
-111206491 | 2010-3-8 0:00:0 | ER | No Violations | |
-1141373954 | 2007-3-26 0:00: | ER | No Violations | |
-1162407133 | 2018-1-18 0:00: | ER | No Violations | |
-1168495110 | 2008-12-24 0:00 | ER | No Violations | |
-1191941869 | 2007-9-11 0:00: | ER | No Violations | |
-1204920510 | 2010-3-8 0:00:0 | ER | No Violations | |
-1261559083 | 2007-11-30 0:00 | ER | No Violations | |
-1366324445 | 2011-7-13 0:00: | SW | No Violations | 1.00 |
-1398335375 | 2015-11-19 0:00 | ER | No Violations | |
-141377828 | 2017-1-23 0:00: | ER | No Violations | |
-1439810991 | 2006-11-29 0:00 | ER | No Violations | |
-1455220122 | 2019-11-5 0:00: | ER | No Violations | |
-1462625639 | 2009-1-22 0:00: | ER | No Violations | |
-1512704181 | 2017-10-20 0:00 | ER | No Violations | |
-1524250826 | 2019-4-7 0:00:0 | ER | No Violations | |
-1541116114 | 2007-5-29 0:00: | ER | No Violations | |
-1576100991 | 2016-5-5 0:00:0 | ER | No Violations | |
-1582727099 | 2011-12-9 0:00: | SW | No Violations | 2.00 |
-158960894 | 2018-7-3 0:00:0 | ER | No Violations | |
-1603323006 | 2007-2-23 0:00: | ER | No Violations | |
-1661497216 | 2019-6-25 0:00: | ER | No Violations | |
-1703253835 | 2004-1-16 0:00: | ER | No Violations | |
-1704805169 | 2004-5-17 0:00: | SW | No Violations | 2.00 |
-1730951932 | 2019-3-4 0:00:0 | ER | No Violations | |
-1745900009 | 2008-11-28 0:00 | ER | No Violations | |
-1748818043 | 2005-2-28 0:00: | ER | No Violations | |
-1755257253 | 2018-5-21 0:00: | ER | No Violations | |
-1774397718 | 2014-6-12 0:00: | ER | No Violations | |
-1779327742 | 2014-7-21 0:00: | ER | No Violations | |
-1784308047 | 2013-11-18 0:00 | ER | No Violations | |
-1818016599 | 2005-6-8 0:00:0 | ER | No Violations | |
-1825116263 | 2004-4-19 0:00: | ER | No Violations | |
-1825992429 | 2016-3-16 0:00: | ER | No Violations | |
-1870942569 | 2009-4-9 0:00:0 | SW | No Violations | |
-2010079986 | 2012-3-2 0:00:0 | SW | No Violations | 1.00 |
-20336250 | 2005-9-14 0:00: | ER | No Violations | |
-208320329 | 2015-3-25 0:00: | ER | No Violations | 3.00 |
-2147058556 | 2019-3-13 0:00: | ER | No Violations | |
-245798818 | 2016-9-8 0:00:0 | ER | No Violations | |
-246072311 | 2010-2-3 0:00:0 | ER | No Violations | |
-296261678 | 2006-2-1 0:00:0 | ER | No Violations | |
-363670512 | 2017-7-27 0:00: | ER | No Violations | |
-422995845 | 2006-10-5 0:00: | ER | No Violations | |
-431998726 | 2016-2-19 0:00: | ER | No Violations | |
-446399801 | 2009-10-6 0:00: | ER | No Violations | |
-457274984 | 2014-8-21 0:00: | ER | No Violations | |
-460757543 | 2010-11-17 0:00 | ER | No Violations | 1.00 |
-467273378 | 2015-5-10 0:00: | ER | No Violations | |
-497566286 | 2006-5-31 0:00: | ER | No Violations | |
-583518953 | 2007-6-25 0:00: | SW | No Violations | |
-606052286 | 2004-6-24 0:00: | ER | No Violations | |
-654142748 | 2003-3-31 0:00: | SW | No Violations | |
-710335680 | 2014-5-14 0:00: | ER | No Violations | |
-760174297 | 2013-5-8 0:00:0 | ER | No Violations | |
-794766374 | 2016-7-6 0:00:0 | ER | No Violations | |
-795551901 | 2010-3-8 0:00:0 | ER | No Violations | |
-842579597 | 2008-10-2 0:00: | ER | No Violations | |
-890988676 | 2003-10-14 0:00 | ER | No Violations | |
0003380706 | 2002-08-01 | Salt Water Injection Well | No Violations | OIL OVERFLOWED SUMP BELOW FACILITY SOMETIME SINCE LAST INSPECTION. CLEAN UP WAS STARTED BUT NEEDS MORE WORK, STRAW NEEDS PICKED UP, MORE DIRT NEEDS REMOVED FERTILIZED RESEEDED AND FRESH MULCH PUT DOWN TO REESTABLISH VEGETATION IN AFFECTED AREA. |
0008554679 | 2003-01-03 | Salt Water Injection Well | No Violations | salt water injection well with Dave Ball |
000PL10014 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
000UIC1693 | 1997-11-04 | Enhanced Recovery Project | No Violations | 1501: 9-3-07 (D) EXCEED MAX. INJ. PSI |
000UIC1694 | 1997-11-04 | Enhanced Recovery Project | No Violations | 1509.03 RULES & REGULATIONS |
001289i497 | 2002-07-05 | Salt Water Injection Well | No Violations | injection side is on vacuum |
0020336250 | 2005-09-14 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Pump was running during my inspection. Housekeeping needed in tank area and unloading area. |
0025482420 | 2005-12-19 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory this inspection.
Noted: Pump was running on the day of my inspection. |
0055319361 | 2003-07-03 | Enhanced Recovery Project | No Violations | No violations noted on the day of my inspection.
(11)housekeeping on unloading pad needed. |
0094578988 | 2016-02-03 | Enhanced Recovery Project | No Violations | Inspection today indicated that injection pump was in operation and it was noted that one Jayhawk Water Service vacuum truck was unloading at the facility during my inspection. |
0103050284 | 2006-09-18 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Vault area in need housekeeping,reminder that drain in unloading pad in need of replacement |
0111206491 | 2010-03-08 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # -1204920510 FOLLOW UP TO NOV # 730931186 An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and dispose |
0141377828 | 2017-01-23 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
0146700117 | 2013-09-20 | Salt Water Injection Well | No Violations | On site to witness tubing and packer run into well again, they pulled tubing to look for leaks in tubing three small pin hole were found in bottom two joints of tubing. |
0158960894 | 2018-07-03 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: One J-Hawk Water Service vacuum truck was on site during my inspection. |
0171273331 | 2009-05-01 | Enhanced Recovery Project | No Violations | No violations at this time. |
0208320329 | 2015-03-25 | Enhanced Recovery Project | No Violations | On site along with staff member from central office to inspect upgrades that are being made to facility. |
0241507706 | 2016-09-27 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation and it was noted that roustabout crew nearly has replacement tanks plumbed up and they plan on start filling storage tanks as early as tomorrow. |
0245798818 | 2016-09-08 | Enhanced Recovery Project | No Violations | On site to witness work crew place new 30 mil liner in reconstructed dike area they plan on placing felt material on top on liner to keep it from being exposed to the elements and place stone in the bottom of dike to place tanks on and plumb piping and within the next couple weeks pressure test new plumbing and place well back into operation. |
0246072311 | 2010-02-03 | Enhanced Recovery Project | No Violations | No violations at this time. |
0272231985 | 2015-07-21 | Enhanced Recovery Project | No Violations | Injection pump was in operation during my inspection and it was noted that one JAYHAWK Water Services vacuum truck arrived on site to dispose of one load of brine. |
0296261678 | 2006-02-01 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note:Clean up needed in vault area! Could use some stone in tank area. |
0316343527 | 2006-12-20 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Noted small amount of oil within tank area called company rep and requested cleanup also unloading pad in need of replacement and stone is needed around facility and housekeeping needed in vault area. |
0357481542 | 2019-02-15 | Enhanced Recovery Project | No Violations | Inspection today indicated that injection pump was not in operation during my inspection and it was noted that one J-Hawk vacuum truck was on site during my inspection. |
0363670512 | 2017-07-27 | Enhanced Recovery Project | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
0375451382 | 2009-04-09 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation today.
Note: Framework on injection pump showing signs of decay it will need to be replaced in the near future also electric supply line going to pump is in need of being raised presently it is a safety issue,also fresh water needs to be removed from dike area to allow for volume in the event of tank failure. |
0422995845 | 2006-10-05 | Enhanced Recovery Project | No Violations | No violation noted, facility appears to be in satisfactory condition this inspection.
Note: Unloading pad in need of repair and vault area in need of housekeeping,fresh water needs to be removed from tank area to allow for volume in the event of tank failure. |
0431998726 | 2016-02-19 | Enhanced Recovery Project | No Violations | Owner called and we discussed that they suspect that they have packer or tubing issue and they ceased operations until futher testing could confirm there thoughts. |
0437649077 | 2013-03-12 | Salt Water Injection Well | No Violations | I accompanied Dave Ball on the inspection and testing of UIC well. The injection well is currently inactive. There are two 300 bbl, two 100bbl, and one 210 bbl tanks on location. |
0446399801 | 2009-10-06 | Enhanced Recovery Project | No Violations | Follow-up on NOV, In-Compliance. |
0446897651 | 2015-11-24 | Enhanced Recovery Project | No Violations | Upon inspection, it was observed that this well is actively injecting as an enhanced recovery well. The well consists of 8.625 surface casing, 4.5 casing, and 2.375 injection tubing. Pressures read 610psi on the tubing and 70 psi on the tubing-casing annulus. The well head area is encased by a steel vault/cellar. The tank battery consists of 6 300 bbl tanks, 2 210 bbl tanks, and 2 100 bbl tanks, all inside of lined earthen containment dikes. No pollution or contamination was observed on the location. The lease road is in good condition. Legible and correct ID information is posted at the entry gate as well as the well head. No violations noted. |
0457274984 | 2014-08-21 | Enhanced Recovery Project | No Violations | Inspection reveled that owner has placed a crew on site to perform weeedeating and clean up duties at site and the well still remains idle and workers were stating that owner is possibly planning on selling this well. |
0460757543 | 2010-11-17 | Enhanced Recovery Project | No Violations | No violations at this time. |
0467273378 | 2015-05-10 | Enhanced Recovery Project | No Violations | Inspection revealed that owner is close on getting well back up and into operation. |
0497566286 | 2006-05-31 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Noted: Unloading pad area in in need of replacement,concrete is starting too show severe signs of fatigue,weedeating also needed around facility as time permits. |
0505919063 | 2005-03-31 | Enhanced Recovery Project | No Violations | On site to witness acid job being preformed on well by Producers Service Corp. on site@8am contractor opened tubing valve and pumped1000 gal. Of 28%acid down well to help clean up restricted formation,displaced with brine at 1 bbl per minute pumped 2000 gal brine behind acid and shut well in with 1000psi on tubing will check pressurs 4/4/05 and operator will put well back into operation. |
0510395919 | 2008-06-04 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note:Old concrete still needs to be removed from site and fresh water in dike area need to be removed,also stone is needed in tank area and housekeeping needed in vault area. |
0577394247 | 2014-02-10 | Salt Water Injection Well | No Violations | Well is still down waiting on owner to submit reconstruction plan for facility. |
0583518953 | 2007-06-25 | Salt Water Injection Well | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Note: Unloading pad is still in need of replacement and stone is needed in tank area and vault area is in need of a good cleaning. |
0603967292 | 2015-03-03 | Enhanced Recovery Project | No Violations | Inspection on this day indicated that roustabout crew was on site plumbing storage tanks and placing new flow line to well head and injection pump house is nearly completed and once completed they will bring it to the site and begin electrical work. |
0606052286 | 2004-06-24 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.Pump not running today.
Weedeating needed at site. |
0654142748 | 2003-03-31 | Salt Water Injection Well | No Violations | No violations noted this inspection
(3)Housekeeping needed in vault area. (4)remove fresh water from tank area. |
0674149798 | 2014-04-16 | Enhanced Recovery Project | No Violations | Inspection revealed that well is down waiting on company to submit plan for placing well back into operation or sell well to a registered owner. |
0694427244 | 2005-05-13 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Will need to apply pressure to annulus of tubing minimum of 200psi and monitor pressure for 15min contact local inspector prior to preforming test so he can witness test. |
0697393834 | 2015-07-10 | Enhanced Recovery Project | No Violations | Inspection revealed that there was no activity at the site today. |
0710335680 | 2014-05-14 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still down waiting on owner to sell well or submit a plan to place well back into operation. |
0715141439 | 2005-11-16 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Housekeeping needed in tank area. Pump in need of repair(fix leaks). |
0730931186 | 2010-03-08 | Enhanced Recovery Project | Violations Noted | An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and disposed |
0760174297 | 2013-05-08 | Enhanced Recovery Project | No Violations | Storage tanks are being cleaned by Sun Pro and solids are being solidified and hauled to a EPA approved landfill. |
0794766374 | 2016-07-06 | Enhanced Recovery Project | No Violations | Inspection today revealed that injection pump was in operation and company rep Joe Snyder was on site during my inspection. |
0795551901 | 2010-03-08 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 730931186 An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and disposed |
0797021547 | 2015-10-13 | Enhanced Recovery Project | No Violations | Inspection on this day indicated that pump was not in operation and it was noted that one J-Hawk water truck was unloading at the facility during my inspection. |
0814817065 | 2019-03-26 | Enhanced Recovery Project | No Violations | Waiting on service rig to pull tubing and packer and replace. |
0842579597 | 2008-10-02 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Old concrete from replacing unloading pad is in need of removal from site and fresh water needs to be removed from tank area to allow for space in the event of tank failure.Pump was not in operation during my inspection. |
0876255559 | 2010-06-23 | Salt Water Injection Well | No Violations | Follow-up on NOV, In-Compliance. |
0880322784 | 2017-06-09 | Enhanced Recovery Project | No Violations | Injection pump not in operation during my inspection and it was noted that one JHAWK vacuum truck was unloading at the facility during my inspection. |
0890988676 | 2003-10-14 | Enhanced Recovery Project | No Violations | no violations noted on day of my inspection.
(11)housekeeping needed in unloading pad area. Note:fresh stone installed around facility. |
0921442148 | 2009-02-20 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation today,it appears that they electrical problems at well site there is evidence of recent electrical work being preformed at site.
Note: Housekeeping work in vault area needed. |
0932929936 | 2005-04-25 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Called operator and told them they needed to apply pressure to annulus of tubing so we can monitor pressures. |
1000609742 | 2007-12-28 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Pump was not in operation on the day of my inspection, annulus pressure on tubing is needed contact inspector prior to applying pressure he wants to be present to monitor pressures. |
1034064802 | 2015-05-13 | Enhanced Recovery Project | No Violations | On site to test flow line to wellhead after it had been replaced during work over project at site they pressured it up too 1125 psi and we monitored it for 15 minutes with no decline in pressure.
Note: Facility has been rebuilt and new injection pump has been put in place and owner opened up downhole valve and well continues to be on slight vacuum will check back at later date to see if it stays on vacuum. |
1041682252 | 2003-01-03 | Enhanced Recovery Project | No Violations | [11]. Check drain line to vault. |
1048739582 | 2003-08-13 | Salt Water Injection Well | No Violations | no violations noted.
(3)clean up in tank area needed (5)house keeping in vault area needed (11)housekeeping in unloading area needed |
1051783027 | 2003-04-30 | Salt Water Injection Well | No Violations | No violations noted,facility appears in good repair,
suggest weedeating around facility more seed-mulch needed around vault area |
1054688013 | 2019-05-06 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still down waiting on owner to have service rig pull tubing and packer to repair well. |
1064490318 | 2003-09-24 | Salt Water Injection Well | No Violations | no violations noted,facility appears to be in good repair.
(11)clean up needed in unloading pad area also clean up in vault area needed. |
1066244817 | 2008-08-28 | Enhanced Recovery Project | No Violations | Facility appears to be in satisfactory condition this inspection,pump was not in operation during my inspection.
Note: Old concrete needs to be removed from site(old unloading pad) and clean up is needed in vault area and new stone is needed in tank area,weed eating is suggested at site!!!1. |
1071577498 | 2013-04-16 | Enhanced Recovery Project | No Violations | Chipco moving in on site to work on well, they plan on pulling tubing an packer and clean out casing back to 4800. |
1075332448 | 2013-04-29 | Enhanced Recovery Project | No Violations | On site to witness another Weatherford packer run in well and we will attempt to pressure test later today once packer is set .Chipco ran 2.375 into well to a depth of 4594 plus packer equals 4598 and they pumped 60 bbl of inhibitor laden fluid down annulus and then we set packer and pressure tested at 1120 psi for 15 minutes with no decline in pressure test passed.
Note: Company states they will start cleaning out storage tanks later this week and start rebuild process at facility. |
1091397175 | 2004-07-30 | Enhanced Recovery Project | No Violations | No violations noted,facility appears to be in satisfactory condition this inspection.
(11)Housekeeping needed in unloading pad area. (4)Freshwater needs to be removed from dike to allow for space within dike in the event of spill. |
1096057023 | 2004-11-30 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Pump not running today. Fresh water needs to be removed from dike area. |
1102724236 | 2004-10-27 | Enhanced Recovery Project | No Violations | No violations noted, facility in satisfactory condition this inspection.
(5)More housekeeping needed in vault area. (11)Housekeeping needed in unloading pad area. |
1112964557 | 2005-04-05 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Well recently had acid job preformed on it to help lower injection presure. Clean up needed below fault area. |
1123867837 | 2005-08-08 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Stone needed in tank area! Housekeeping needed in vault area! Pump not running on the day of my inspection. |
1141373954 | 2007-03-26 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Noted plumbing at pump showing signs of possible future failure call and left message with Ken Parsons stating that plumbing on pup would need to be changed,also unloading pad still needs to be replaced also housekeeping needed in tank area. |
1162407133 | 2018-01-18 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that one J-Hawk truck was unloading during my inspection. |
1168495110 | 2008-12-24 | Enhanced Recovery Project | No Violations | Pump was not in operation during my inspection, noted that new drive belts have been installed on electric motor,fresh water in tank area need to be removed as soon as weather permits. |
1170436155 | 2007-01-31 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Unloading pad is still in need of replacement also stone is needed around facility to ensure driver safety during winter weather conditions(entering icy drive&exiting) pump was not in operatin during my inspection. |
1179395334 | 2015-06-10 | Enhanced Recovery Project | No Violations | Well not in operation today due to electrical issues within the pump house area and there was a electrician on site making repairs at the time of my inspection. |
1191941869 | 2007-09-11 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Pump was not in operation during my inspection,unloading pad area is still in need of replacement suggest that you notify your drivers not to unload trucks on driveway use whats left of unloading pad. |
1194005479 | 2014-11-05 | Enhanced Recovery Project | No Violations | Inspection revealed that new owners are working on getting facility ready to go back into operation in the near future. |
1194997276 | 2007-11-13 | Enhanced Recovery Project | No Violations | On site to witness company personnel remove unloading pad, and install new drain to vault and prepare site for new concrete, operator removed old slab approximately 10 wide and 30 long ,plans are to install rebar and replace pad 11/14/07 will witness job to ensure that operator has good integrity on cement job cement will be approximately 8 -10 thick with rebar in place. |
1195316821 | 2007-11-14 | Enhanced Recovery Project | No Violations | On site to witness well owner replace unloading pad at site,13 yds of concrete with rebar installed was used to replace pad and new drain box was also replaced discussed other issues at site that will be corrected at later date. |
1202932277 | 2008-02-12 | Enhanced Recovery Project | No Violations | On site to witness Sweeny Well Service apply annulus pressure to back side of tubing he pressured up to 300 psi and we monitored pressure for 15 min no decline in pressure we left pressure on backside of tubing.Mini-test passed. |
1204920510 | 2010-03-08 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 730931186 An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and dispose. RESOLVED - well is now in operation, per Dave Ball. |
1206132301 | 2008-03-20 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Fresh water needs to be removed from dike area to allow for space in the event of tank failure,also old unloading pad material is in need of removal from site,injection pump was not in operation on the day of my inspection. |
1210838879 | 2008-05-13 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Pump was not running during my inspection, also old concrete from unloading pad replacement is in need of removal from site and stone is needed in tank area as discussed earlier. |
1221861925 | 2008-09-18 | Enhanced Recovery Project | No Violations | Inspection revealed that pump was not in operation during my inspection,well tender was on site weed eating around tanks told him that old concrete from unloading pad replacement needs to be removed from site he stated that he would contact well owner and make arrangements to have it removed. |
1248364054 | 2009-07-22 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed oily material around the storage tanks and in sump. Contaminated material at storage tank and pump area. |
1251906960 | 2009-09-02 | Enhanced Recovery Project | No Violations | Follow up on NOV, Non-Compliance, no action taken to clean up contaminated materials at storage tanks and repair leak on water pump. Injection pressure and annulus pressure close, may need a mini test. |
1261559083 | 2007-11-30 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Well is not in operation, owner waiting for concrete to cure(poured new unloading pad)once set well will be placed into operation, told well tender annulus pressure needed to be applied before placing well into operation. |
1289i15469 | 2002-10-17 | Salt Water Injection Well | No Violations | NO VIOLATIONS NOTED |
1289i15469093 | 2002-10-17 0:00 | SW | No Violations | |
1289i21457 | 2002-03-27 | Annular Disposal | No Violations | A.D. WELL |
1289i21457278 | 2002-3-27 0:00: | AD | No Violations | |
1289i497 | 2002-7-5 0:00:0 | SW | No Violations | |
1317851648 | 2011-10-04 | Salt Water Injection Well | Violations Noted | Inspection this day found facility still down - pump not running - needs repairs, well not in operation. Time to either plug well or put in operation. |
1347422572 | 2006-07-19 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.Inspected site with company rep and advised them of weedeating needed at site vault area in need of attention and also work needed in unloading pad area. |
1366295219 | 2013-04-17 | Enhanced Recovery Project | No Violations | On site to witness Chipco release packer and pull tubing and then run tubing back in hole with bit on bottom and casing scrapper on top of bit we tagged fill up inside of casing at 4638then decision was made to get power swivel and drill out fillip and then reperforate Clinton sand and then perform acid job and then run new Weatherford packer in hole and try and set it at 4660. |
1366324445 | 2011-07-13 | Salt Water Injection Well | No Violations | Inspection this day found well not in operator - looks like has not taken water in a long time. Taked to Dave Ball and he says pump trouble - well has been shut down and pump needs serviced. No pressure on well. |
1366453176 | 2013-04-18 | Enhanced Recovery Project | No Violations | Inspection revealed that Chipco Services rig crew ran working string in well to attempt to drill out obstruction within casing and then clean out casing to 4800,it appears that at some point someone had lost unknown steel object inside of casing and that would not allow working string to go to bottom, we came out of hole and install impression block on bottom of tubing then ran it in well and it appeared that there was a pipe wrench lodged within casing@4638 we will make up milling assembly in morning and attempt to mill it up. |
1366826637 | 2013-04-22 | Enhanced Recovery Project | No Violations | On site to witness milling of old packer and then clean out inside of casing to a total depth of 4803called Central office to confirm that operator could perforate Medina sand and it was confirmed that it was allowed. |
1375584431 | 2006-03-30 | Enhanced Recovery Project | No Violations | No violations noted,pump was running on the day of my inspection,facility appears to be in satisfactory condition this inspection.
Suggest replacing unloading pad, concrete is breaking up due to fact of truck traffic,housekeeping is needed in vault area,need to apply pressure to annulus of tubing ASAP. |
1392694512 | 2013-04-26 | Enhanced Recovery Project | No Violations | On site to witness a 2000 gal acid job being preformed on Clinton /Medina Sands and once test packer was pulled started new Weatherford Ultra Lok packer in hole and once we ran 4627 of tubing they set packer and we tried to pressure test but it failed we lost 100psi within 7 minutes so decision was made to move packer up the hole 1 joint and try again it failed pressure testing also so decision was made to pull packer on 4/29/13 and examine elements and then run it back in hole and try to test it again. |
1394487238 | 2014-03-10 | Enhanced Recovery Project | No Violations | Waiting on owner to submit plan for rebuilding facility. |
1398335375 | 2015-11-19 | Enhanced Recovery Project | No Violations | Inspection today indicated that injection pump was note in operation and it was noted that one Jayhawk Water Services vacuum truck was unloading at the facility during my inspection. |
1420866349 | 2003-12-08 | Enhanced Recovery Project | No Violations | No violations noted,facility appears to be in satisfactory condition,
(5)Vault full called Gib Wetzler and informed him to get vault pumped down. |
1423162226 | 2015-02-04 | Enhanced Recovery Project | No Violations | Inspection on this day indicated that well is still down waiting on new owner to finish making upgrades to facility and once they get new pump house done and plumbed up they will go into operation. |
1423169097 | 2013-04-23 | Enhanced Recovery Project | No Violations | On site to witness Appalachian Well Services log well and then reperforate Clinton section and Medina section also Medina perfs are as follows 4744-4770-156 shots and Clinton perfs are at 4655-4680-211 perforations, top of cement on backside of 4.5 is at 4200 confirmed by wire line log. |
1424991182 | 2015-02-26 | Enhanced Recovery Project | No Violations | |
1430218370 | 2017-04-23 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that concrete pad for trash dumpster has bee put in place and plumbing from trash area is going to approved vault systemm in which fluids are pumped to storage tanks. |
1439810991 | 2006-11-29 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection,
Uloading pad is still in need of replacement and vault area is in need of housekeeping ,tank area could use fresh stone around tanks! |
1456171501 | 2016-02-22 | Enhanced Recovery Project | No Violations | Met company rep on site to witness setting of test tank to verify that packer still has integrity they plumbed up annulus side of tubing and bled pressure off and we monitored it for and signs of flow none was detected during a one hour test period. |
1462625639 | 2009-01-22 | Enhanced Recovery Project | No Violations | Inspection revealed that pump was not in operation today it appears that well is not being used much at this time due to weather conditions.
Note: Stone is needed around facility and hosekeeping is needed in vault area. |
1465847093 | 2016-06-13 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one JHAWK vacuum truck was unloading at the facility during my inspection. |
146700117 | 2013-9-20 0:00: | SW | No Violations | |
1470000370 | 2016-07-28 | Enhanced Recovery Project | No Violations | Received phone call from company rep Joe Snieder stating that lightning had just struck facility and storage tanks were ablaze and M/M Fire department was enroute to scene to put fire out with foam suppressant and once fire was out we assessed damage.
Note: All fluids were contained within dike and we estimated that 4 bbl. oil and 30 bbl. of brine was released within dike and they had vacuum trucks pull fluids from remaining tanks and it was hauled to another disposal well and properly disposed of. |
1470230169 | 2016-08-02 | Enhanced Recovery Project | No Violations | Inspection today revealed that owner is in the process of removing tanks from dike area, they had a recent lightning strike and containment area was compromised and 1-160 bbl. lay down tank received damage. |
1499114225 | 2003-02-06 | Enhanced Recovery Project | No Violations | No violations noted this inspection.
(2) Install 1/4plugs in valves to protect threads. (9) General housekeeping in pump area. |
1512704181 | 2017-10-20 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation on this day of my inspection and it was noted that one J-Hawk vacuum truck was unloading at the facility during my inspection. |
1521139764 | 2013-01-18 | Enhanced Recovery Project | No Violations | Inspection revealed that injection well has been out of service for quite sometime, will contact company rep requesting that they put well back into operation or plug said well. |
1522421471 | 2018-03-28 | Enhanced Recovery Project | No Violations | Inspection today revealed that injection pump was not in operation during my inspection and it was noted that one J-Hawk vacuum truck was onsite offloading during my inspection. |
1524250826 | 2019-04-07 | Enhanced Recovery Project | No Violations | Well is currently down awaiting repair. |
1541116114 | 2007-05-29 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Note: Unloading pad is still in need of replacement trucks appear to be unloading from driveway since unloading pad is inpassible,also vault area in need of housekeeping and tank area also in need of a good cleaning. |
1542971540 | 2007-10-31 | Salt Water Injection Well | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection this inspection.
Note: Unloading pad is in need of replacement and new drain lines installed to vault&new stone placed in tank area,pump was in operation during my inspection. |
1546092907 | 2011-04-08 | Enhanced Recovery Project | No Violations | On site to witness injection testing preformed by Producers Services they pumped water and KCL solution into well at 3/10ths bbl per min and we monitored pressures testing began@8.21 A.M and ended@10.16 A.M. company rep John Gaydos will discuss findings with corporate office and decision will be made on what they plan on doing with well. |
1561148784 | 2019-6-18 0:00: | ER | No Violations | 12.00 |
1565978132 | 2008-02-01 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note:, pump was not in operation during my inspection, also noted that pump was showing signs of leakage need to have well tender check for leakage next time pump is in operation and you need to apply pressure to annulus of tubing!!. |
1576100991 | 2016-05-05 | Enhanced Recovery Project | No Violations | Injection pump not in operation during my inspection and it was noted that one J-Hawk water truck was unloading at the facility during my inspection. |
1582727099 | 2011-12-09 | Salt Water Injection Well | No Violations | Met with John Geydos, Salt Water Disposal Well Specialist, from Select Energy Services, on location. The well is shut in and there has been no change in status. Talked about how they would proceed getting this well back in operation. Said he would submit a written plan to Tom Tomastik and I and they should start getting well back in operation after January 1. John said the pump will have to be replaced also. |
1603323006 | 2007-02-23 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Note: Unloading pad is still in need of replacement as soon as weather permits,also vault area in need of attention. |
1606713982 | 2007-08-02 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Note: Companay personnel was present during my inspection(working on pump) he stated that he was doing mainitence work on pump,we discussed issues at well site also unloading pad is still in need of replacement and housekeeping needed in vault area!!!! |
1631597767 | 2018-04-17 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that one JHAWK vacuum truck was on site offloading during my inspection. |
1658770384 | 2016-11-09 | Enhanced Recovery Project | No Violations | Inspection today indicated that injection pump was in operation and it was noted that one J-HAWK vacuum truck was unloading at the facility during my inspection. |
1665371965 | 2013-12-12 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on plan from corporate office either to refurbish facility or plug/sell well. |
1703253835 | 2004-01-16 | Enhanced Recovery Project | No Violations | No violations noted ,facility appears to be in satisfactory condition today.
Housekeeping needed in unloading area. |
1704805169 | 2004-05-17 | Salt Water Injection Well | No Violations | No violations noted,facility appears to be in satisfactory condition this inspection.
(11) Housekeeping needed in unloading area. |
171273331 | 2009-5-1 0:00:0 | ER | No Violations | |
1714995913 | 2015-10-14 | Enhanced Recovery Project | No Violations | Inspection on this day indicated that injection pump was not in operation and we measured dike for compliance and it was determined that they had plenty of excess volume in the event of a spill. |
1719888035 | 2014-12-10 | Enhanced Recovery Project | No Violations | Inspection revealed that well is not in operation at this time in conversation with company rep Joe Snyder stating that they are currently having new pump house and filter house built. |
1730951932 | 2019-03-04 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
1745900009 | 2008-11-28 | Enhanced Recovery Project | No Violations | Inspection revealed that pump was not in operation during my inspection.
Noted that old concrete has been removed from site since my last inspection,housekeeping needed in vault area. |
1748818043 | 2005-02-28 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
Called company rep and advised him that vault was getting full and needed emptied he stated he would have truck out at site this afternoon,also reccomended that he get tranfer pump at vault repaired or replaced. |
1755257253 | 2018-05-21 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was in operation today and it was noted that one J-Hawk vacuum truck was on site offloading during my inspection. |
1769822494 | 2010-03-08 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 730931186 An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and disposed |
1770226040 | 2004-09-22 | Enhanced Recovery Project | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
(3)Clean-up needed in tank area. Noted: New sump pump installed in vault. |
1774397718 | 2014-06-12 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still down and after talking to company well caretaker stating that the company does not have any plans to make facility capable of operation.
Note: Injection pump is in need of replacement and plumbing needs replaced and there is one storage tank that needs replaced if well is placed back into operation, Recommend Chiefs Order to plug well or place well back into operation in a timely manner we worked on replacing tubing and packer two years ago and they have not made any attempts to place well into operation. |
1779327742 | 2014-07-21 | Enhanced Recovery Project | No Violations | Inspection revealed that current owner has not made any attempts to place well back into operation since they reworked well two years ago. |
1780859828 | 2008-07-11 | Enhanced Recovery Project | No Violations | No violations noted this inspection,pump was not in operation on the day of my inspection.
Note: Old concrete from replacing unloading pad is still in need of removal from site and housekeeping is needed invault area. |
1784308047 | 2013-11-18 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still down waiting on facility reconstruction. |
1808908481 | 2003-02-06 | Enhanced Recovery Project | No Violations | No violations noted this inspection.
(2)install 1/4 plugs in valves to protect threads. (9) General housekeeping in pump area. |
1818016599 | 2005-06-08 | Enhanced Recovery Project | No Violations | No violations noted, facility in satisfactory condition this inspection.
Stone needed in tank area. Restoration work needed below vault area. |
1825116263 | 2004-04-19 | Enhanced Recovery Project | No Violations | No violations noted,facility appears to be in satisfactory condition this inspection.
(11)housekeeping needed in unloading pad area. |
1825992429 | 2016-03-16 | Enhanced Recovery Project | No Violations | Inspection revealed that injection pump was in operation and it was noted that one J-HAWK vacuum truck was unloading at the facility during my inspection. |
1843402010 | 2018-12-10 | Enhanced Recovery Project | No Violations | Inspection today indicated that injection pump was not in operation during my inspection and it was noted that one J-HAWK vacuum truck was on site during my inspection. |
1865325525 | 2012-04-18 | Salt Water Injection Well | No Violations | UIC facility inspection, well is down awaiting repair of pump and possibly acid job to be preformed. |
1870942569 | 2009-04-09 | Salt Water Injection Well | No Violations | DAVE BALL AND I STOPPED TO GET PRESSURE READINGS.PUMP IS NOT RUNNING.160 PSI ON TUBING PRESSURE.230 PSI ON ANNULAR PRESSURE. |
1894581976 | 2019-6-17 0:00: | SW | No Violations | 0.80 |
1899407812 | 2011-10-04 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1317851648 Inspection this day found facility still down - pump not running - needs repairs, well not in operation. Time to either plug well or put in operation. |
1909588128 | 2013-01-31 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still not in operation and it was noted that owner is currently having storage tanks cleaned.
Note: They will need to have injection pump and plumbing replaced before placing well back into operation. |
1944338265 | 2013-04-19 | Enhanced Recovery Project | No Violations | On this day we ran 3.875 mill in well to drill up obstruction within casing we sat down@4638 and began milling they milled to 4710 today and will resume operations on Monday. |
1962152127 | 2016-08-11 | Enhanced Recovery Project | No Violations | Inspection revealed that all storage tanks have been removed from dike area and once liner is in place they will place tanks back into containment area and plumb them back up and place well back into operation. |
1969239306 | 2019-9-3 0:00:0 | ER | No Violations | |
1974035226 | 2012-10-10 | Salt Water Injection Well | No Violations | Inspection revealed that well has been down for several months due to pump problems.
Note: One lay down storage tank is showing signs of fatigue it will need to be emptied and put out of service ASAP. Also fresh water tank area needs to be removed as time permits. |
2010079986 | 2012-03-02 | Salt Water Injection Well | No Violations | My inspection this day due to quarterly requirements. I found no change from last inspection - facility not running and looks as though no one has been to well in long time. I will not resolve citation this day. |
2049833670 | 2004-03-04 | Enhanced Recovery Project | No Violations | No violations noted facility appears to be in satisfactory condition this inspection.
(5)Electric pump in vault in need of repair&dike around vault also needs work preformed on back wall. |
2050625329 | 2013-03-12 | Enhanced Recovery Project | No Violations | Inspection revealed that well is still down awaiting on plan to rebuild facility or plug said well. |
2093717470 | 2010-03-08 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 1769822494 FOLLOW UP TO NOV # 730931186 An inspection of the storage facility revealed oily material in piles in dike area. Contaminated materials around water pump, and water pump leaking brine onto the ground. ALL contaminated materials need to be cleaned up and removed from site and disposed |
2147058556 | 2019-03-13 | Enhanced Recovery Project | Violations Noted | Inspection revealed that pressures were equalized on tubing and annulus, instructed operator to cease operations and submit repair plan to the division for approval.
|
241507706 | 2016-9-27 0:00: | ER | No Violations | |
25482420 | 2005-12-19 0:00 | ER | No Violations | |
272231985 | 2015-7-21 0:00: | ER | No Violations | |
316343527 | 2006-12-20 0:00 | ER | No Violations | |
3380706 | 2002-8-1 0:00:0 | SW | No Violations | |
357481542 | 2019-2-15 0:00: | ER | No Violations | |
375451382 | 2009-4-9 0:00:0 | ER | No Violations | |
407925915 | 2020-1-24 0:00: | ER | No Violations | |
437649077 | 2013-3-12 0:00: | SW | No Violations | 1.50 |
446897651 | 2015-11-24 0:00 | ER | No Violations | 1.50 |
505919063 | 2005-3-31 0:00: | ER | No Violations | |
510395919 | 2008-6-4 0:00:0 | ER | No Violations | |
55319361 | 2003-7-3 0:00:0 | ER | No Violations | |
577394247 | 2014-2-10 0:00: | SW | No Violations | |
603967292 | 2015-3-3 0:00:0 | ER | No Violations | |
674149798 | 2014-4-16 0:00: | ER | No Violations | |
694427244 | 2005-5-13 0:00: | ER | No Violations | |
697393834 | 2015-7-10 0:00: | ER | No Violations | |
714289740 | 2020-6-11 0:00: | ER | No Violations | |
715141439 | 2005-11-16 0:00 | ER | No Violations | |
730931186 | 2010-3-8 0:00:0 | ER | No Violations | |
797021547 | 2015-10-13 0:00 | ER | No Violations | |
814817065 | 2019-3-26 0:00: | ER | No Violations | |
8554679 | 2003-1-3 0:00:0 | SW | No Violations | |
876255559 | 2010-6-23 0:00: | SW | No Violations | 1.00 |
880322784 | 2017-6-9 0:00:0 | ER | No Violations | |
921442148 | 2009-2-20 0:00: | ER | No Violations | |
932929936 | 2005-4-25 0:00: | ER | No Violations | |
94578988 | 2016-2-3 0:00:0 | ER | No Violations | |
PL10014 | PL | No Violations | ||
UIC1693 | 1997-11-4 0:00: | ER | No Violations | |
UIC1694 | 1997-11-4 0:00: | ER | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0730931186 | US-OH-128265 | 2010-03-09 | Pollution/Contamination | |
0730931186 | US-OH-128266 | 2010-03-09 | Storage facilities contamination (permit before 6/1/82) | |
0730931186 | US-OH-128267 | 2010-03-09 | Equipment pressure rated below operating pressure | |
0730931186 | US-OH-128268 | 2010-03-09 | Failure to keep dike or pit free of brine or other wastes | |
1248364054 | US-OH-106614 | 2009-07-23 | Well operation causing pollution and contamination | |
1248364054 | US-OH-106615 | 2009-07-23 | Equipment pressure rated below operating pressure | |
1248364054 | US-OH-106616 | 2009-07-23 | No SPCC dike/or failure to keep dike free of water or oil | |
1248364054 | US-OH-106617 | 2009-07-23 | Pollution/Contamination | |
1317851648 | US-OH-109081 | 2014-04-10 | Well shall be plugged | |
2147058556 | US-OH-122057 | 2019-05-10 | 9-5-10(H) | Mechanical failure/contamination |
For data sources see[9]