X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-22796

Well Details

Well ID: 34-115-22796
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Bloom Township
Operator Name: M & R INVESTMENTS OHIO LLC
Well Pad ID:
Farm/Lease Name: APPERSON
License Status: Active Injection
License Date: 1983-03-23
Spud Date: 1982-04-07
Spud Drilling Contractor: EASY DRILLING
Final Drill Date: 1982-04-14
Well Total Depth: 4618.00 ft
Configuration: Vertical
Latitude: 39.710000
Longitude: -81.840000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1982-04-07 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Reached Total Depth 1982-04-14 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
CO 1983-03-23 1177 ENERGY DISTRIBUTORS INC GeoDate 3/23/83
Conversion to Injector 1983-03-23
Salt Water Injection Well 1983-03-23 Issued Date 3/23/83 Expired Date 9/19/83 Acres 0040000 Tool Type NT Proposed Formation CINN. SHALE Proposed Depth 03070 Proposed Drill Depth 03070
Storage Well 1983-03-23 Issued Date 3/23/83 Expired Date 9/19/83 Acres 0040000 Tool Type NT Proposed Formation CINN. SHALE Proposed Depth 03070 Proposed Drill Depth 03070
Completed 1983-03-29 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
First Injection 1983-04-20 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Construction Permit Expires 1983-09-19 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Completion Report Received 1987-07-21 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
CO 1991-12-11 3071 KINGSTON OIL CORP GeoDate 3/23/83
Annulus Pressure Monitoring Approved 1993-02-09 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Plugged Back 1993-02-09 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Change of Owner 2001-02-01 Operator changed from 3071, KINGSTON OIL CORP to 6918, RESOURCES WELL SERVICES INC
Last Compliance Report 2001-02-05 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN
Change of Owner 2017-10-13 Operator changed from 6918, RESOURCE WELL SERVICES LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-10-19 WELL CONVERTED TO INJECTION 04/06/1983 - IT IS NOT PLUGGED AND ABANDONED PF=CINN

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-02 2272 2287 8
2000-05-02 4447 4541 1
2272 2287 8
4447 4541 1
2272 2287 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
FOAM 0 65000 Gal 0
0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 CHEVRON APPALACHIA LLC 0.00 52.00 365
2002 CHEVRON APPALACHIA LLC 0.00 269.00 365
2003 ATLAS NOBLE LLC 0.00 55.00 365
2004 ATLAS NOBLE LLC 0.00 212.00 365
2005 ATLAS NOBLE LLC 0.00 0.00 365
2006 ATLAS NOBLE LLC 0.00 114.00 365
2007 ATLAS NOBLE LLC 0.00 111.00 365
2008 ATLAS NOBLE LLC 0.00 227.00 366
2009 ATLAS NOBLE LLC 0.00 105.00 365
2010 ATLAS NOBLE LLC 0.00 154.00 365
2011 ATLAS NOBLE LLC 0.00 157.00 0
2012 ATLAS NOBLE LLC 0.00 63.00 366
2013 ATLAS NOBLE LLC 0.00 42.00 365
2014 ATLAS NOBLE LLC 0.00 83.00 365
2015 ATLAS NOBLE LLC 0.00 43.00 365
2017 ATLAS NOBLE LLC 0.00 0.00 182
2018 M & R INVESTMENTS OHIO LLC 0.00 35.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 CHEVRON APPALACHIA LLC Brine 0 365
2002 CHEVRON APPALACHIA LLC Brine 462 365
2003 ATLAS NOBLE LLC Brine 0 365
2004 ATLAS NOBLE LLC Brine 60 365
2005 ATLAS NOBLE LLC Brine 39 365
2006 ATLAS NOBLE LLC Brine 60 365
2007 ATLAS NOBLE LLC Brine 80 365
2008 ATLAS NOBLE LLC Brine 21 366
2009 ATLAS NOBLE LLC Brine 40 365
2010 ATLAS NOBLE LLC Brine 4 365
2011 ATLAS NOBLE LLC Brine 6
2012 ATLAS NOBLE LLC Brine 314 366
2013 ATLAS NOBLE LLC Brine 227 365
2014 ATLAS NOBLE LLC Brine 360 365
2015 ATLAS NOBLE LLC Brine 365
2017 ATLAS NOBLE LLC Brine 6 182
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-102577858 2014-11-5 0:00: SW No Violations
-1038966043 2004-6-24 0:00: SW No Violations
-1086277539 2003-1-3 0:00:0 SW No Violations
-1215874130 2016-5-5 0:00:0 SW No Violations
-1287217509 2014-5-14 0:00: SW No Violations
-1309528600 2013-9-18 0:00: SW No Violations
-1350697905 2019-2-15 0:00: SW No Violations
-1379622401 2006-9-18 0:00: SW No Violations
-1392295078 2010-8-5 0:00:0 SW No Violations 1.00
-1504592380 2013-3-12 0:00: SW No Violations 1.00
-1554553215 2019-6-25 0:00: SW No Violations
-1571829869 2012-10-10 0:00 SW No Violations
-1605135689 2003-9-24 0:00: SW No Violations
-1605289458 2017-6-9 0:00:0 SW No Violations
-1647728568 2005-6-8 0:00:0 SW No Violations
-1782550311 2008-10-2 0:00: SW No Violations
-1824674642 2009-4-9 0:00:0 SW No Violations
-1840494610 2003-2-6 0:00:0 SW No Violations
-1862725635 2016-9-27 0:00: SW No Violations
-1885969437 2019-9-4 0:00:0 SW No Violations
-1961871564 2018-3-28 0:00: SW No Violations
-2003744067 2011-12-9 0:00: SW No Violations 1.00
-2022533077 2005-4-25 0:00: SW No Violations
-202968 2011-7-13 0:00: SW No Violations 1.00
-2067983640 2015-10-14 0:00 SW No Violations
-208404426 2009-2-6 0:00:0 SW No Violations
-2087771228 2012-4-18 0:00: SW No Violations
-2147383493 2008-2-1 0:00:0 SW No Violations
-290995904 2020-1-24 0:00: SW No Violations
-308981830 2004-7-30 0:00: SW No Violations
-455061555 2019-9-3 0:00:0 SW No Violations
-513234034 2004-11-9 0:00: SW No Violations
-526419686 2008-11-28 0:00 SW No Violations
-624421120 2003-8-13 0:00: SW No Violations
-636214554 2009-1-22 0:00: SW No Violations
-669001935 2018-4-17 0:00: SW No Violations
-750021963 2006-2-1 0:00:0 SW No Violations
-8970587 2008-7-11 0:00: SW No Violations
-918111176 2010-11-17 0:00 SW No Violations 0.50
-951765843 2017-1-23 0:00: SW No Violations
-976031662 2016-6-13 0:00: SW No Violations
0000202968 2011-07-13 Salt Water Injection Well No Violations Inspection this day found pump not running. Tubing pressure was 350#, annulus was 40#. All looked neat and clean, expecially at facility up on highway.
0008970587 2008-07-11 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Company owned vac truck was unloading at facility during my inspection stopped and talked to driver discussing minor issues of housekeeping at unloadind facility.

000UIC1622 1996-03-27 Salt Water Injection Well No Violations 1509.22 (A),(C),(1),(3) STORAGE & DISPOSAL
000UIC1623 1996-03-27 Salt Water Injection Well No Violations 1501: 9-3-04(A) PREVENT CONTAMINATE
000UIC1624 1996-03-27 Salt Water Injection Well No Violations 1501: 9-3-05(A)(7) CONSTRUCT FACILITIES
000UIC1753 1999-02-24 Salt Water Injection Well No Violations 1501: 9-03-08 TEMPORARILY STORAGE
0012480611 2002-09-23 Salt Water Injection Well No Violations FOUND HAMMER UNION LEAKING, FROM UNLOADING PAD TO RUN OFF TANK. HAMMER UNION TIGHTENED UP IMMEDIATELY UPON REQUEST TO WATER TRUCK DRIVER AND WELL TENDER.
001289i499 2002-07-05 Salt Water Injection Well No Violations no violations noted this inspection.
001289i500 2002-07-08 Salt Water Injection Well No Violations NO VIOLATIONS NOTED
0029260072 2010-02-03 Salt Water Injection Well No Violations No violations at this time.
0102577858 2014-11-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it appears that well is not used much at this time.
0103099958 2008-03-20 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, also vegetation needs to be established on east side dike wall!!.

0208404426 2009-02-06 Salt Water Injection Well No Violations Well owner called and stated that vac truck operator ran tank over and spilled approximatly 2 bbl oil in dike area,inspected site and advised them on cleanup that was needed they placed absorbant pads on affected area and recovered all free standing oil and properly disposed of oil laden material,I suggested that they monitor site once weather condition were above freezing and they stated that was part of there cleanup plan.
0300935966 2013-11-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
0308981830 2004-07-30 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

Note:Walked flowline.

0380622918 2007-09-11 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Pump was not in operation during my inspection, noted small leak on fluid end of pump suggest having well tender make required repairs as soon as possible.
0425489013 2006-03-30 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted: New 210 bbl storage tank at facility too replace the one that is showing signs of possible failure.

0440557397 2010-03-08 Salt Water Injection Well No Violations No violations at this time.
0449939672 2004-03-04 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

1/4 valve needs replaced on annulus side of wellhead (8)stone needed to cover liner-to protect from sunlight (11)Housekeeping needed in unloading pad area. Could use some stone on lease road to wellhead.

0465798929 2007-03-26 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Walked flowline to monitor area for possible leakage(none found). Suggest owner clean-up around unloading pad (old heater tube and misc debris.

0513234034 2004-11-09 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(7) Need to maintain pressure on annulus of tubing.

0525824517 2007-10-31 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Walked flow line area to monitor for possible leaks none found),pump was not running on the day of my inspection.

0526419686 2008-11-28 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, also noted that stone is starting to fall off of liner suggest that as weather permits apply adhesive and apply more stone to liner.

0542341616 2013-03-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during our inspection and it was noted that building up by unloading pad is in need of replacement and faulty tank is also in need of replacement.
0546623966 2015-11-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0621307227 2014-07-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that unloading pad was recently steamed cleaned.
0624421120 2003-08-13 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair.

(1)need I.D.refreshed at wellhead (11)housekeeping needed in unloading area/ Note:Walked flowline

Pump not running on day of my inspection

0636214554 2009-01-22 Salt Water Injection Well No Violations Inspection revealed that well was not in operation today,noted that well has not been operating during bad weather conditions.

Walked flow line area to monitor area for potential leaks( none found).

0643746011 2008-09-18 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation during my inspection, walked flow line area to monitor area for potential leaks (none found) well tender was weed eating at unloading pad area during my inspection.
0669001935 2018-04-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0712218447 2003-03-31 Salt Water Injection Well No Violations No violations noted this inspestion.

(3)More clean-up needed at tank area at well head (11)General housekeeping in unloading area.

0750021963 2006-02-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was running on the day of my inspection,noted at unloading pad 210 bbl tank showing signs of needing replaced,called company rep Gary Haught and discussed plans for tank replacement.

0796498726 2006-07-31 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump was not running today, still waiting on owner too change out suspected faulty tank at unloading pad area in my last conversation with well tender he stated that they were trying to arrange for a crane to perform tank change.

0797057054 2010-06-23 Salt Water Injection Well Violations Noted An inspection of the well revealed oily material in dike around storage tanks. Oily material needs cleaned up and disposed of in a proper manner.
0832546498 2004-10-27 Salt Water Injection Well No Violations No violations noted facility in satisfactory condition this inspection.

Need to hold pressure on annulus of well at least 200# Noted company brine hauler unloading at site during my inspection UIC#317

0834995774 2006-11-29 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted that pump was in operation on the day of my inspection also walked area of flow line to check for possible leaks none found.

0878220796 2015-02-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today due to extreme cold weather, well tender stated they plan on starting injection pump later this week.
0918111176 2010-11-17 Salt Water Injection Well No Violations No violations at this time.
0951765843 2017-01-23 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it was noted that valves going to storage located at wellhead area were closed and it appears that well is not being used much at this time.

Note: Talked to company rep Chuck Woods requesting that they have stone applied to drive going to wellhead it is currently in need of repair.

0958607593 2009-04-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection,company owner vac truck was unloading at site on the day of my inspection.

Note: Fresh water needs to be removed from dike area to allow for volume in the event of tank failure.

0976031662 2016-06-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1005931300 2005-09-14 Enhanced Recovery Project No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump not running today. Need to apply pressure to annulus of tubing.

1030677662 2015-07-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that company owned truck was unloading at the facility during my inspection.
103099958 2008-3-20 0:00: SW No Violations
1038966043 2004-06-24 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

On site to witness setting of new 210bbl storage tank Baker Crane Rental preformed work at site! Why is well under FR status?

1054223763 2003-05-28 Salt Water Injection Well No Violations no violations noted,facility appears in good repair
1057411136 2003-07-03 Salt Water Injection Well No Violations No violations noted on the day of my inspection.

(11)housekeeping in unloading area needed.

1065968967 2003-10-14 Salt Water Injection Well No Violations no violations noted,facility appears to be in good repair.

(2)I.D.at wellhead needs refreshed (11)Housekeeping needed in unloading pad area. Note:All tanks at site have been painted facility looks good.

1070974812 2003-12-08 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.
1074355439 2004-01-16 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition this inspection.

Hammer union on high pressure hose at well head showing signs of need of repair.

1081957396 2005-02-28 Salt Water Injection Well No Violations No violations noted facility in satisfactory condition this inspection,pump was running on the day of my inspection.Preformed mini test on annulus of tubing(Sweeney Well Services) pressured up to 350 psi with fresh water&anhib and held pressure for 15 min with no decline in pressure Test Passed.
1085749138 2004-05-26 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

On location to witness mini test on annulus os well Sweeney Well Service added fresh water to annulus&pressured up to 290psi and held pressure for 15 min.TEST PASSED.

1086277539 2003-01-03 Salt Water Injection Well No Violations (7) Valve needs replaced on casing
1096208563 2004-09-22 Salt Water Injection Well No Violations No violations noted, facility in satisfactory condition this inspection.

(5)Union on two inch pipe going to storage tank needs replaced. (11)Housekeeping needed in unloading area.

1101233079 2016-02-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and I called company rep Charles Woods to request that they make plans for a MIT test on said well.
1102016229 2004-11-30 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

On site to witness Sweeney Well Service pressure test annulus of tubing(mini test) operator applied 250psi and held pressure for 15min with no decline in pressure.

1102916196 2004-05-17 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(7)Need to add pressure to annulus so we can monitor integrity of tubing and packer.

1112566638 2005-03-31 Salt Water Injection Well No Violations On site to witness operator preform pressure test on annulus of tubing,operator installed new 2 valves on tubing head hooked up Sweney Well Service and applied 250 psi(fresh water&anhib) and held pressure for 15 min with no decline in pressure Mini Test Passed.
1119509551 2009-07-22 Salt Water Injection Well No Violations No violations at this time.
1132433113 2005-11-16 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted:Storage tanks have been recently painted. Called company rep Mark Warehime and told him to apply pressure to annulus of tubing he stated he had Sweeny Well Service scheduled to preform test 11/22/05.

1135170143 2005-12-19 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted: Pump was running on the day of my inspection,also walked flowline.

1149205732 2006-05-31 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump not in operation today,walked flow line to check for possible leaks none located. Noted weedeating has been preformed around facility.

1170435650 2007-01-31 Salt Water Injection Well No Violations On site to witness mini test of annulus of tubing Sweeny Well Service preformed test 500# of pressured applied to annulus and pressure monitored for 15 min with no decline in pressure test passed, no violations noted on the day of my inspection.
1180606720 2007-05-29 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump was not in operation during my inspection, walked flow line area to monitor for possible leaks none found).

1188605606 2007-08-31 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was not in operation during my inspection, also walked flwline area to monitor area for possible leaks (none found). Housekeeping needed in unloading pad area!!!.

1204118835 2005-08-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Need to apply pressure to annulus of tubing! Pumpnot running during my inspection.

1212791097 2008-06-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Sweeny Well Service applied pressure to annulus of tubing as requested from last inspection,housekeeping needed in unloading pad area old hoses etc need to be removed from site.

1215874130 2016-05-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it appears that well is not used much at this time.
1223662625 2007-12-28 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection,fresh water is in need of removal from tank area dike to allow for volume in the event of tank failure.

1228834682 2009-05-01 Salt Water Injection Well No Violations No violations at this time.
12480611 2002-9-23 0:00: SW No Violations
1263543972 2007-11-30 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, also walked flow line area to monitor for potential leaks (none found).

1287217509 2014-05-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection but it was noted that one company owned vacuum truck was unloading at facility UIC#25-317.
1289i15569 2002-10-17 Salt Water Injection Well No Violations NO VIOLATIONS NOTED
1289i15569094 2002-10-17 0:00 SW No Violations
1289i21557 2002-03-27 Annular Disposal No Violations A.D. WELL
1289i21557279 2002-3-27 0:00: AD No Violations
1289i22453 2001-05-16 Salt Water Injection Well No Violations
1289i22453806 2001-5-16 0:00: SW No Violations
1289i499 2002-7-5 0:00:0 SW No Violations
1289i500 2002-7-8 0:00:0 SW No Violations
1293182694 2016-08-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1301926871 2009-09-02 Salt Water Injection Well No Violations No violations at this time.
1309528600 2013-09-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that wellhead and all of the storage tanks have been repainted since my last inspection.
1320831439 2014-03-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not running today.
1326819025 2017-07-27 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time.
1330953825 2012-03-02 Salt Water Injection Well No Violations My inspection this day found the injection pump not running - gauge test showed 120# on the tubing and 100# on the annulus. I met Bob Dusenberry, the pumper down at the injection site and he went over the inspection with me. Identification was good - Bob says they do not take much water at this site.
1350697905 2019-02-15 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and company rep Ed Lafollette was on site checking fluid levels in tanks and changing filters while I was on site.
1364936320 2013-04-01 Salt Water Injection Well No Violations Inspection revealed that owner had steamers on site to clean out two faulty tanks they will replace them on 4/3/2013.
1365029609 2013-04-03 Salt Water Injection Well No Violations On site to witness owner change out two faulty storage tanks, Baker Crane Service was on site also to lift tanks from within dike area and also to place new tanks in dike.

Injection pump was not in operation during my inspection and it was also noted that owner was going to replace part of the injection pump plumbing while work crew was hooking up new tanks.

1365339320 2008-12-24 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection,housekeeping needed in unloading pad area and they could use some stone on driveway to storage tanks.
1379622401 2006-09-18 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was not in operation during my inspection also noted that unloading pad had been cleaned since my last inspection,walked area of flow line to monitor for possible leaks.

1392242974 2014-02-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today due to extreme cold weather conditions.
1392295078 2010-08-05 Salt Water Injection Well No Violations Follow-up on NOV, In-Compliance.
1417270618 2012-10-16 Salt Water Injection Well No Violations Onsite to witness mini test preformed on annulus of tubing B&E Well Services was on site to perform required testing,they pressured up to 520 psi and we monitored pressure for 15 minutes with no decline in pressure.

Note: Faulty storage tanks at facility still needs to be replaced.

1446425169 2006-12-20 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump not running during my inspection.

1447894194 2017-10-20 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
1454793637 2018-05-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1455908402 2016-02-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and I talked to Ed Lafollette vacuum truck driver about letting management be aware of MIT testing on annulus of said well.
1467351899 2018-07-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.
1472515575 2005-05-13 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted weedeating has been preformed around tank&unloading pad area. Pump not running on the day of my inspection.

1478720363 2016-11-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation and it appears that well is not used much at this time.
1504592380 2013-03-12 Salt Water Injection Well No Violations I accompanied Dave Ball on the inspection and testing of UIC well. Bob Dewsberry, the well tender, was on location, and the pump was running at the time of arrival. There are three 210 barrel tanks and one 100 bbl tank.
1516381930 2018-01-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Walked flowline area to monitor area for any potential leaks none were detected.

1531687346 2018-07-13 Salt Water Injection Well No Violations On site today to witness MIT testing of said well they applied 600 psi and we monitored pressure for 30 minutes with no decline in pressure.(TEST PASSED)
1544636957 2018-12-10 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and company driver was on site filtering water and it was noted that valve on annulus of tubing was froze up and I was unable to record pressure.
1555092009 2019-04-07 Salt Water Injection Well No Violations Inspection today revealed that the injection pump was not in operation during my inspection.
1571829869 2012-10-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today, company still has not changed out faulty tanks at site.

Note: Pressure needs to be applied to annulus of tubing as time permits contact inspector prior to doing so he can witness testing of well.

1605135689 2003-09-24 Salt Water Injection Well No Violations No violations noted,facility appears in good repair this inspection.

(2)need I.D. at wellhead refreshed (11)housekeeping needed in unloading pad area. Note:Tanks are in process of being painted.

1605289458 2017-06-09 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and currently well is not being used much.
1647728568 2005-06-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was in operation on the day of my inspection. Note:Walked flowline.

1664766109 2017-04-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that a two pen recorder has been put in place on well as suggested in previous inspections and conversations with company rep Chuck Woods.
1665271681 2007-02-23 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump was not in operation during my inspection,unloading pad in need of a good cleaning as weather permits.

1684013088 2003-01-03 Salt Water Injection Well No Violations salt water injection well with Dave Ball
1703439796 2008-05-13 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, also noted that new unloading line has been installed at unloading site.

1722079350 2016-08-11 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation today and it appears that well is not used much at this time.

Note: Called Chuck Woods and requested that they have fresh water removed from dike area in the near future.

1736478156 2011-10-04 Salt Water Injection Well No Violations Inspection this day found brine kill area around well, downhill from dike around tanks. Hay has been put down - operator had reported this to me but not able to inspect until now - no grass growing. Called operator and Mark said put 2 bags of lime down, hay and seed - asked him to put down more lime and seed. Checked well and it had 10# on tubing, 40# on annulus. Rest of facility looked good, little fresh water inside dike around down at well.
1782550311 2008-10-02 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection,company owned vac truck was unloading at facility during my inspection.

Note: 2x1 swedge in need of replacement at pump it was showing signs of fatigue,also remove all trash@pump site as time permits.

1795793775 2004-04-19 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(11)Housekeeping needed in unloading pad area.

1824674642 2009-04-09 Salt Water Injection Well No Violations DAVE BALL AND I STOPPED BY AND TOOK PRESSURE READINGS FROM ANNULUS AND TUBING PRESSURE.ANNULAR PRESSURE WAS 300PSI.TUBING PRESSURE WAS 380PSI.
1840494610 2003-02-06 Salt Water Injection Well No Violations No violations noted,walked flow line.

(11) House keeping in unloading pad area. (3)Clean up needed around pump area.

1844961724 2015-05-13 Salt Water Injection Well No Violations Well not in operation today and it was noted that owner has recently placed spill clean up kit at site for quicker cleanup response in the event of spill.
1862725635 2016-09-27 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it appears the well is not being used much at this time.


Note: Weed eating has been performed at wellhead and around storage tank site recently.

1961871564 2018-03-28 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
1968439052 2007-06-25 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Note: Walked flow line area to monitor for possible leaks( none found)pump was not in operation during my inspection also noted that unloading pad is due for a good cleaning.

2003744067 2011-12-09 Salt Water Injection Well No Violations Pump was not running. Visible tire tracks indicate that trucks have left water today. The well and the tanks are properly identified. There is 80 PSI on the tubing, 40 PSI on the annulus. There is some standing water in the diked area. The grass is growing well where there was a brine spill earlier in summer.
2022533077 2005-04-25 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted company owned vac truck was unloading brine into tanks during my inspection.

2028924769 2017-06-09 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it appears that well is not used much at this time.
2039231654 2008-08-28 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition this inspection, noted that unloading pad area has been cleaned since my last inspection.Note: Walked flow line area to monitorarea for potential laks none found,pump was not in operation during my inspection.
2067983640 2015-10-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during our inspection.

Note: Measured dike for compliance and it was determined that they had plenty of excess volume.

2087771228 2012-04-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that 1-210 bbl at lower tank site has been placed out of service due to fact that bottom seam on tank is bad and also 1-210 at unloading pad area has been placed out of service due to leakage, called and discussed getting tanks replaced and company rep stated that they have work order submitted to be approved by corporate office.
2112207666 2003-02-06 Salt Water Injection Well No Violations (3)Housekeeping in unloading area.

(11)Clean up around pump area. No violations noted this inspection,walked flow line to well head.

2147383493 2008-02-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was not in operation during my inspection also noted a couple damp spots on pump have well tender monitor it for leaks next time he has pump running.

29260072 2010-2-3 0:00:0 SW No Violations
300935966 2013-11-18 0:00 SW No Violations
380622918 2007-9-11 0:00: SW No Violations
425489013 2006-3-30 0:00: SW No Violations
440557397 2010-3-8 0:00:0 SW No Violations
449939672 2004-3-4 0:00:0 SW No Violations
465798929 2007-3-26 0:00: SW No Violations
525824517 2007-10-31 0:00 SW No Violations
542341616 2013-3-12 0:00: SW No Violations
546623966 2015-11-19 0:00 SW No Violations
558202199 2020-6-11 0:00: SW No Violations
621307227 2014-7-21 0:00: SW No Violations
637749231 2019-11-5 0:00: SW No Violations
643746011 2008-9-18 0:00: SW No Violations
712218447 2003-3-31 0:00: SW No Violations
733695743 2019-7-17 0:00: SW No Violations
796498726 2006-7-31 0:00: SW No Violations
797057054 2010-6-23 0:00: SW No Violations 1.00
832546498 2004-10-27 0:00 SW No Violations
834995774 2006-11-29 0:00 SW No Violations
878220796 2015-2-4 0:00:0 SW No Violations
958607593 2009-4-9 0:00:0 SW No Violations
iTOMK00007 2000-09-12 Salt Water Injection Well Violations Noted
iTOMK000079 2000-9-12 0:00: SW No Violations
iTOMK00008 2000-09-12 Salt Water Injection Well Violations Noted
iTOMK000084 2000-9-12 0:00: SW No Violations
UIC1622 1996-3-27 0:00: SW No Violations
UIC1623 1996-3-27 0:00: SW No Violations
UIC1624 1996-3-27 0:00: SW No Violations
UIC1753 1999-2-24 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0797057054 US-OH-129066 2010-06-23 No SPCC dike/or failure to keep dike free of water or oil
0797057054 US-OH-129067 2010-06-23 Pollution/Contamination
iTOMK00007 US-OH-131620 Pollution/Contamination
iTOMK00007 US-OH-131621 Contamination at surface facility (permit after 6-1-82)
iTOMK00008 US-OH-131625 Pollution/Contamination
iTOMK00008 US-OH-131626 Contamination at surface facility (permit before 6-1-82)

For data sources see[9]

References