34-115-22820

Well Details

Well ID: 34-115-22820
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Center Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: SILVUS FRED & ROBERT UNIT
License Status: Producing
License Date: 1982-05-14
Spud Date: 1982-06-21
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1982-06-25
Well Total Depth: 5543.00 ft
Configuration: Vertical
Latitude: 39.620000
Longitude: -81.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-05-14 471 EAGLE MOUNTAIN ENERGY GeoDate 5/14/82
Oil and Gas 1982-05-14 Issued Date 5/14/82 Expired Date 11/1/82 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05543 Proposed Drill Depth 05543
Original Spud 1982-06-21
Completed 1982-06-25
Reached Total Depth 1982-06-25
Completion Report Received 1982-07-15
Construction Permit Expires 1982-11-01
Change of Owner 1999-04-30 Operator changed from 471, EAGLE MOUNTAIN ENERGY to 4801, BANCEQUITY PETROLEUM CORP
Last Compliance Report 2016-11-10
Change of Owner 2018-05-04 Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 9086, GENESIS RESOURCES LLC
Record Last Modified 2018-05-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5216 5302 0
5216 5302 0
2006-09-11 5297 5302 5
5297 5302 5
5216 5302 0
2006-09-11 5352 5370 36

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 50000 FRAC: 1200 BBL H2O, 50M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 EAGLE MOUNTAIN ENERGY 11779.00 64.00 0
1985 EAGLE MOUNTAIN ENERGY 5004.00 0.00 365
1986 EAGLE MOUNTAIN ENERGY 4600.00 0.00 365
1987 EAGLE MOUNTAIN ENERGY 4189.00 48.00 365
1988 EAGLE MOUNTAIN ENERGY 4980.00 0.00 365
1989 EAGLE MOUNTAIN ENERGY 3888.00 0.00 365
1990 EAGLE MOUNTAIN ENERGY 2258.00 35.00 365
1991 EAGLE MOUNTAIN ENERGY 0.00 0.00 365
1994 EAGLE MOUNTAIN ENERGY 0.00 0.00 365
1996 EAGLE MOUNTAIN ENERGY 0.00 0.00 365
1997 EAGLE MOUNTAIN ENERGY 0.00 0.00 365
1998 EAGLE MOUNTAIN ENERGY 0.00 0.00 365
2011 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2012 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2013 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2014 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2015 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2016 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2017 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2018 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 EAGLE MOUNTAIN ENERGY Brine 0 0
1985 EAGLE MOUNTAIN ENERGY Brine 0 365
1986 EAGLE MOUNTAIN ENERGY Brine 15 365
1987 EAGLE MOUNTAIN ENERGY Brine 17 365
1988 EAGLE MOUNTAIN ENERGY Brine 14 365
1989 EAGLE MOUNTAIN ENERGY Brine 21 365
1990 EAGLE MOUNTAIN ENERGY Brine 32 365
1991 EAGLE MOUNTAIN ENERGY Brine 59 365
1994 EAGLE MOUNTAIN ENERGY Brine 35 365
1996 EAGLE MOUNTAIN ENERGY Brine 0 365
1997 EAGLE MOUNTAIN ENERGY Brine 0 365
1998 EAGLE MOUNTAIN ENERGY Brine 0 365
2011 BANCEQUITY PETROLEUM CORPORATI Brine 0
2012 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2013 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2014 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2015 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2016 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2017 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2018 BANCEQUITY PETROLEUM CORPORATI Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1394959959 2019-3-28 0:00: PW No Violations 0.50
-525715207 2019-1-16 0:00: PW No Violations 0.50
0000PL9935 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0460657224 2016-08-24 Temporary Abandoned Annular Disposal No Violations The inspection revealed that this well is not hooked up for TAAD. The well is equipped with a rabbit unit, 4 1/2 inch diameter well head, 1 1/2 inch diameter production tubing, and 2 inch diameter production tubing. This well is capable of production from the 4 1/2 inch diameter well head. The tank battery is equipped with a 100 barrel tank and a horizontal separator unit.
0525715207 2019-01-16 Production Wells Violations Noted I was on location today to do a field inspection on this well. During my inspection I was unable to locate any identification for this well. The well is required to have legible identification posted either at the well or at the production tank. If there is more than one well producing into the same production tank the identification is required to be at both the well and the production tank. The identification must have the following on it. The owner, lease name, well number, permit number, county and emergency contact number.
1394959959 2019-03-28 Production Wells No Violations I was back on location today to follow-up on the identification for this well. The identification has still not been corrected to the new owner. I will reach out to the company again to let them know it still needs done.
1594212921 2020-7-8 0:00:0 PW No Violations 0.50
1869328484 2020-6-2 0:00:0 PW No Violations 0.50
460657224 2016-8-24 0:00: TD No Violations 2.00
PL9935 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0525715207 US-OH-125747 2019-01-17 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]