X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-22967

Well Details

Well ID: 34-115-22967
Country: United States
State: Ohio
County: Morgan
Municipality: Center Township
Operator Name: CENTURY WELL SERVICE
Well Pad ID:
Farm/Lease Name: MORRIS HEIRS
License Status: Producing
License Date: 1982-10-19
Spud Date: 1982-10-27
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1982-10-31
Well Total Depth: 5688.00 ft
Configuration: Vertical
Latitude: 39.640000
Longitude: -81.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-10-19 Issued Date 10/19/82 Expired Date 4/17/83 Acres 0080000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05688 Proposed Drill Depth 05688
Original Spud 1982-10-27
Completed 1982-10-31
Reached Total Depth 1982-10-31
CO 1982-12-21 56 BUCKEYE OIL PRODUCING CO GeoDate 10/19/82
Completion Report Received 1983-01-28
Construction Permit Expires 1983-04-17
Change of Owner 2007-04-25 Operator changed from 56, BUCKEYE OIL PRODUCING CO to 4350, CENTURY WELL SERVICE. THIS TRANSFER TOOK PLACE 9/18/96. THE TRANSFER DIDN'T UPDATE OR WAS NOT TRANSFERRED.
Last Compliance Report 2014-04-15
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5402 5465 0
5402 5465 0
2006-09-11 5543 5555 2
5543 5555 2
5402 5465 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1262 Bbl 35000 FRAC: 1262 BBL H2O, 35M SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BT ENERGY CORP 14116.00 0.00 365
1986 BT ENERGY CORP 11107.00 0.00 365
1987 BUCKEYE OIL PRODUCING CO 9847.00 0.00 365
1988 BUCKEYE OIL PRODUCING CO 8703.00 0.00 365
1989 BUCKEYE OIL PRODUCING CO 6229.00 0.00 365
1990 BUCKEYE OIL PRODUCING CO 4678.00 0.00 365
1991 BUCKEYE OIL PRODUCING CO 3765.00 0.00 365
1992 BUCKEYE OIL PRODUCING CO 3137.00 0.00 365
1993 BUCKEYE OIL PRODUCING CO 2466.00 0.00 365
1994 BUCKEYE OIL PRODUCING CO 2115.00 0.00 365
1995 BUCKEYE OIL PRODUCING CO 425.00 0.00 365
1996 CENTURY WELL SERVICE 0.00 0.00 365
1997 CENTURY WELL SERVICE 0.00 0.00 365
2001 BUCKEYE OIL PRODUCING CO 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BT ENERGY CORP Brine 0 365
1986 BT ENERGY CORP Brine 18 365
1987 BUCKEYE OIL PRODUCING CO Brine 0 365
1988 BUCKEYE OIL PRODUCING CO Brine 60 365
1989 BUCKEYE OIL PRODUCING CO Brine 0 365
1990 BUCKEYE OIL PRODUCING CO Brine 0 365
1991 BUCKEYE OIL PRODUCING CO Brine 0 365
1992 BUCKEYE OIL PRODUCING CO Brine 0 365
1993 BUCKEYE OIL PRODUCING CO Brine 45 365
1994 BUCKEYE OIL PRODUCING CO Brine 0 365
1995 BUCKEYE OIL PRODUCING CO Brine 0 365
1996 CENTURY WELL SERVICE Brine 60 365
1997 CENTURY WELL SERVICE Brine 0 365
2001 BUCKEYE OIL PRODUCING CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1086959004 2008-6-24 0:00: AD No Violations
-1372048003 2010-5-20 0:00: PW No Violations 1.00
-1654442390 2010-5-20 0:00: PW No Violations 1.00
-1694268487 2020-4-15 0:00: OR No Violations 1.50
-1716888845 2010-5-20 0:00: PW No Violations 1.00
-194075536 2016-3-17 0:00: PW No Violations 3.00
-2110114385 2008-3-24 0:00: AD No Violations
-2758668 2008-3-24 0:00: AD No Violations
-355436349 2010-5-20 0:00: PW No Violations 1.00
-656611784 2010-5-20 0:00: PW No Violations 1.00
0000PL9876 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0002758668 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 284744658. Upon inspecting this site I found this well to be idle. This well is equipped with 4.5 production casing and tubing. All valves at the wellhead were shut on the day of my inspection. The annular disposal was not hooked up and there is no production tank. The last reported production for this well was back in 1995. 2011 - Well inspected this year and is still idle. There are no identification signs posted at this site.
0047184188 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 778754296 FOLLOW UP TO NOV # 284744658 Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank co
0194075536 2016-03-17 Production Wells No Violations Upon my inspection today I found there to be a rabbit well equipped with 2 inch ball valves and production lines. Previous inspections have stated this well is idle and at the time of inspection the well is still idle. The steel tubs have begun to rot away and all valves are closed. Upon closer inspection the smell of H2S could be smelt coming of the well. The area around the well has been overgrown with brush. There has been no resolution to any of the issues with this well.
0284744658 2008-03-24 Annular Disposal Violations Noted Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank could be found and no I.D. posted.h2s odor noted at wellhead!!!!
0355436349 2010-05-20 Production Wells No Violations FOLLOW UP TO NOV # -1654442390 An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all fittings leaking on well head. No ID at well head, all producing leases shall be legibly identified in a conspicuous place on or near the well-head and the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number.
0505496939 2016-05-18 Production Wells No Violations Upon my inspection today I found there to be a rabbit well equipped with 2 inch ball valves and production lines. This well is still currently idle at the time of inspection. The steel tubes have begun to rot away and all valves are closed. Upon closer inspection the smell of H2S could be smelt coming of the well. The area around the well has been overgrown with brush. There has been no resolution to any of the issues with this well.
0510621827 2014-07-29 Production Wells No Violations Compliance Follow-up -1654442390: The well is still idle and equipped with a rabbit pump system. There has been no resolution to any of the issues.
0656611784 2010-05-20 Production Wells No Violations FOLLOW UP TO NOV # -1654442390 An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all fittings leaking on well head. No ID at well head, all producing leases shall be legibly identified in a conspicuous place on or near the well-head and the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number.
0778754296 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 284744658 Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank co
0779371309 2009-03-11 Annular Disposal Violations Noted Inspection revealed that there has been no change in status of well it is still incapable of producing in its present state of repair,owner has made no attempts to resolve previous Notice of Violation issued in 2008.
0871320528 2016-10-05 Production Wells No Violations The inspection today revealed that the well is equipped with a plunger lift system with 2 inch diameter ball valves, 1 1/2 inch production pipeline, and 2 inch diameter production lines. This well is still currently idle at the time of inspection with its valves closed in. The steel tubes have begun to rot away at the well head. Upon closer inspection the smell of sulfur could be smelled coming of the well but, my H2S detector was unable to detect and H2S. The area around the well has been overgrown with brush. There has been no resolution to any of the issues with this well.
1086959004 2008-06-24 Annular Disposal No Violations Follow up inspection revealed no change in status of well it is still incapable of producing,contacted well owner and discussed future plans for well she stated that they were putting a plugging program together and hopefully they will get them done in the near future.
1121667802 2016-11-25 Production Wells No Violations the inspection today revealed that this well is a gas unit equipped with a 4 1/2 inch diameter wellhead, 1 1/2 inch diameter production tubing, and 2 inch diameter steel production lines. The valves on the wellhead and production lines are still closed at this time This well is still currently idle at the time of inspection. The steel tubes have begun to rot away and all valves are closed. Upon closer inspection the smell of sulfur could be smelled coming of the well. My gas meter was unable to detect any H2S at the time of inspection. The area around the well has been overgrown with brush. There has been no resolution to any of the issues with this well. Tanks were unable to be located at the time of inspection.
1231881180 2009-01-13 Annular Disposal No Violations Well is still incapable of producing in its present state of repair,called and discussed well with company rep Leslie Gearhart and she stated they sold well to Northwood Energy Itold her that tranfer has not been received yet they were still responsible for well until tranfer is complete.
1372048003 2010-05-20 Production Wells No Violations FOLLOW UP TO NOV # -355436349 FOLLOW UP TO NOV # -1654442390 An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all fittings leaking on well head. No ID at well head, all producing leases shall be legibly identified in a conspicuous place on or near the well-head and the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number.
1394471585 2014-03-10 Production Wells No Violations Compliance Follow-up -1654442390: The well is still idle and equipped with a rabbit pump system. There has been no resolution to any of the issues.
1436453363 2015-07-09 Production Wells No Violations I went out to this well to do a follow-up inspection on it. The well is still currently idle at this time. The valves are shut in at the well making the well incapable of production. There is a slight smell of h2s at the well area. The flow line has rotted coming off of the well. I have taken pictures of the well today for my records.
1506269591 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # -2758668 FOLLOW UP TO NOV # 284744658. Upon inspecting this site I found this well to be idle. This well is equipped with 4.5 production casing and tubing. All valves at the wellhead were shut on the day of my inspection. The annular disposal was not hooked up and there is no production tank. The last reported production for this well was back in 1995. 2011 - Well inspected this year and is still idle. There are no identification signs posted at this site.
1512667206 2010-05-20 Production Wells No Violations FOLLOW UP TO NOV # -1716888845 FOLLOW UP TO NOV # -1654442390 An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all
1574861313 2019-11-27 0:00 PW No Violations 1.00
1654442390 2010-05-20 Production Wells Violations Noted An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all fittings leaking on well head. No ID at well head, all producing leases shall be legibly identified in a conspicuous place on or near the well-head and the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number.
1689539822 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 284744658 Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank could be found and no I.D. posted.h2s odor noted at wellhead!!!!
1716888845 2010-05-20 Production Wells No Violations FOLLOW UP TO NOV # -1654442390 An inspection of the well revealed well is idle, no production reported on well to Division since 2001. Place well into production or plug. It appears well may have H2S, fittings has corrosion and scales and starting to leak, smells of H2S. Replace all
1776204634 2013-11-04 Production Wells No Violations Compliance Action Follow-up -1654442390: There has been no resolution to any of the issues.
1834545332 2008-11-12 Annular Disposal Violations Noted Well is still idle and incapable of producing H2S ordor detected at wellhead have talked to company rep with no results in getting well into production,according to company rep well should have transferred to Broadstreet Energy they are working on getting well transferred?,
1921475897 2018-06-20 Production Wells No Violations I have returned to this well today to do a follow-up inspection on it for being idle and incapable of production. At this time the well is still sitting idle with no change in the status of it. There is an order on the well for it to be plugged. I will talk with my supervisor about it.
2049612442 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 284744658 Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank could be found and no I.D. posted.h2s odor noted at wellhead!!!!
2110114385 2008-03-24 Annular Disposal No Violations FOLLOW UP TO NOV # 1689539822 FOLLOW UP TO NOV # 284744658 Upon inspecting site found well to be idle,last production reported on well was back in 1995 well is equipped with 4,5 production casing and tubing all valves at wellhead were shut on the day of my inspection,A.D. was not hooked up,no production tank could be found and no I.D. posted.h2s odor noted at wellhead!!!!
284744658 2008-3-24 0:00: AD No Violations
448177667 2020-5-19 0:00: TD No Violations 0.50
47184188 2008-3-24 0:00: AD No Violations
505496939 2016-5-18 0:00: PW No Violations 1.00
510621827 2014-7-29 0:00: PW No Violations
778754296 2008-3-24 0:00: AD No Violations
779371309 2009-3-11 0:00: AD No Violations
871320528 2016-10-5 0:00: PW No Violations 1.00
PL9876 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0284744658 US-OH-122955 2008-03-24 Well not equipped to prevent escape of oil and/or gas
0284744658 US-OH-122956 2008-03-24 Failure to legibly identify well
0284744658 US-OH-122957 2008-03-24 Well shall be plugged
0779371309 US-OH-128843 2008-03-24 Well not equipped to prevent escape of oil and/or gas
0779371309 US-OH-128844 2008-03-24 Failure to legibly identify well
0779371309 US-OH-128845 2008-03-24 Well shall be plugged
1654442390 US-OH-116335 2010-05-31 Well shall be plugged
1654442390 US-OH-116336 2010-05-31 Forfeiture of bond
1654442390 US-OH-116337 2010-05-31 General Safety
1654442390 US-OH-116338 2010-05-31 Failure to legibly identify well
1654442390 US-OH-116339 2010-05-31 Equipment pressure rated below operating pressure
1834545332 US-OH-118313 2008-03-24 Well not equipped to prevent escape of oil and/or gas
1834545332 US-OH-118314 2008-03-24 Failure to legibly identify well
1834545332 US-OH-118315 2008-03-24 Well shall be plugged

For data sources see[9]

References