Well ID: 34-115-22981
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Marion Township
Operator Name: M & R INVESTMENTS OHIO LLC
Well Pad ID:
Farm/Lease Name: COOK
License Status: Active Injection
License Date: 1984-01-12
Spud Date: 1982-12-08
Spud Drilling Contractor: LEE GRIM DRLG
Final Drill Date: 1982-12-19
Well Total Depth: 1498.00 ft
Configuration: Vertical
Latitude: 39.460000
Longitude: -81.890000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-11-02 Issued Date 11/2/82 Expired Date 5/1/83 Acres 0010000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
CO 1982-12-06 386 ULLMAN OPERATIONS INC GeoDate 12/6/82
Oil and Gas 1982-12-06 Issued Date 11/2/82 Expired Date 5/1/83 Acres 0010000 Tool Type RTA Proposed Formation 2ND BEREA Proposed Depth 01498 Proposed Drill Depth 01498
Original Spud 1982-12-08 R.L., CONVERT 12-17-83
Completed 1982-12-19 R.L., CONVERT 12-17-83
Reached Total Depth 1982-12-19 R.L., CONVERT 12-17-83
CO 1982-12-22 386 ULLMAN OPERATIONS INC GeoDate 11/2/82
Completion Report Received 1983-11-21 R.L., CONVERT 12-17-83
CO 1983-12-13 386 ULLMAN OPERATIONS INC GeoDate 12/13/83
Salt Water Injection Well 1983-12-13 Issued Date 1/12/84 Expired Date 7/9/84 Acres 0010000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1983-12-13 Issued Date 1/12/84 Expired Date 7/9/84 Acres 0010000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Conversion to Injector 1984-01-12
First Injection 1984-04-01 R.L., CONVERT 12-17-83
Construction Permit Expires 1984-07-09 R.L., CONVERT 12-17-83
Annulus Pressure Monitoring Approved 1987-08-15 R.L., CONVERT 12-17-83
Plugged Back 1987-08-15 R.L., CONVERT 12-17-83
CO 1994-01-25 4350 CENTURY WELL SERVICE GeoDate 12/13/83
CO 1994-10-21 3437 CEMCO OPERATING INC GeoDate 12/13/83
Last Compliance Report 2001-02-21 R.L., CONVERT 12-17-83
Change of Owner 2003-12-22 Operator changed from 3437, CEMCO OPERATING INC to 4350, CENTURY WELL SERVICE
Change of Owner 2007-10-03 Operator changed from 4350, CENTURY WELL SERVICE to 7033, BROAD STREET ENERGY COMPANY
Change of Owner 2008-02-14 Operator changed from 7033, BROAD STREET ENERGY COMPANY to 8312, BROAD STREET SERV LLC
Change of Owner 2015-07-16 Operator changed from 8312, BROAD STREET SERV LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-10-19 R.L., CONVERT 12-17-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-02 1388 1392 2
1388 1392 2
1388 1392 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
FOAM 0 600 Bbl 20000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 CEMCO OPERATING INC 0.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 10.00 0.00 0
2017 M & R INVESTMENTS OHIO LLC 0.00 0.00 0
2018 M & R INVESTMENTS OHIO LLC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 CEMCO OPERATING INC Brine 872 365
2016 M & R INVESTMENTS OHIO LLC Brine 1163 0
2017 M & R INVESTMENTS OHIO LLC Brine 7020 0
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1053325317 2011-7-12 0:00: SW No Violations 1.00
-108772901 2007-2-23 0:00: SW No Violations
-1113765494 2011-12-1 0:00: SW No Violations 1.50
-1204384962 2005-2-2 0:00:0 SW No Violations
-123371581 2003-10-17 0:00 SW No Violations
-1422153085 2017-9-11 0:00: SW No Violations
-149525708 2008-5-12 0:00: SW No Violations
-1557278331 2008-2-1 0:00:0 SW No Violations
-1659229813 2009-6-4 0:00:0 SW No Violations
-1780806901 2007-3-8 0:00:0 SW No Violations
-1783788130 2013-10-4 0:00: SW No Violations
-1825744289 2018-5-21 0:00: SW No Violations
-1844755307 2012-6-12 0:00: SW No Violations
-1867466501 2007-11-15 0:00 SW No Violations
-1934481192 2018-12-10 0:00 SW No Violations
-1987342447 2007-8-2 0:00:0 SW No Violations
-1994779986 2017-4-23 0:00: SW No Violations
-2005854757 2014-4-2 0:00:0 SW No Violations
-201115653 2014-8-27 0:00: SW No Violations
-2035998772 2008-9-29 0:00: SW No Violations
-2114289015 2007-12-24 0:00 SW No Violations
-2115263678 2003-12-8 0:00: SW No Violations 2.00
-228434719 2007-1-31 0:00: SW No Violations
-546983537 2014-3-27 0:00: AD No Violations 1.00
-550597980 2008-6-4 0:00:0 SW No Violations
-553021839 2006-1-25 0:00: SW No Violations
-576867572 2015-3-4 0:00:0 SW No Violations
-608948256 2007-7-2 0:00:0 SW No Violations
-623435037 2004-9-8 0:00:0 SW No Violations
-624023431 2012-3-9 0:00:0 SW No Violations 1.00
-624281182 2013-1-31 0:00: SW No Violations
-631385714 2015-1-15 0:00: SW No Violations 1.00
-684225442 2004-9-27 0:00: SW No Violations 1.00
-730922733 2016-5-5 0:00:0 SW No Violations
-741057799 2009-2-20 0:00: SW No Violations
-760036727 2004-4-15 0:00: SW No Violations
-781138854 2014-3-10 0:00: SW No Violations
-79739624 2013-12-6 0:00: SW No Violations 4.00
-829435269 2005-5-11 0:00: SW No Violations
-843108839 2019-3-4 0:00:0 SW No Violations
-855458174 2003-7-9 0:00:0 SW No Violations
-893927087 2006-9-14 0:00: SW No Violations
-933826890 2004-4-12 0:00: SW No Violations 1.00
-960452135 2006-12-19 0:00 SW No Violations
0000PL9866 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0000UIC100 1987-03-17 Salt Water Injection Well No Violations 1501:9-3-04(A)
0000UIC293 1987-03-17 Salt Water Injection Well No Violations 1501:9-3-04 (A)
0000UIC470 1987-10-01 Enhanced Recovery Project No Violations 1509.22(A)(1&2)(C)(3)
0000UIC471 1987-10-01 Salt Water Injection Well No Violations 1501:9-3-04 (A)(6)
0000UIC520 1988-03-24 Salt Water Injection Well No Violations ACTION NOMSV 1509.22 (A)(1)(2)(C)(1)(3 Permit Hold List
0000UIC521 1988-03-24 Salt Water Injection Well No Violations ACTION NOMSV 1501:9-3-04 (A) Permit Hold List
0000UIC522 1988-03-24 Salt Water Injection Well No Violations ACTION NOMSV 1501:9-3-05 (A)(6) Permit Hold List
0000UIC709 1989-06-13 Salt Water Injection Well No Violations 1501:9-5-10 (E) Delinquent Qtly Rpt.
0000UIC829 1989-12-19 Salt Water Injection Well No Violations 1501:9-3-07 (E) monitor/rept.
0000UIC830 1989-12-19 Salt Water Injection Well No Violations 1501:9-3-07 (F) monitor annulus
000UIC1210 1992-01-07 Salt Water Injection Well No Violations 1501: 9-3-07 (E) QUARTERLY REPORTS
000UIC1211 1992-01-07 Salt Water Injection Well No Violations 1501: 9-3-07 (F) ANNULUS MONITORING
000UIC1529 1994-09-27 Salt Water Injection Well Violations Noted 1501: 9-3-07 (F) ANNULUS MONITORING
000UIC1805 1999-10-25 Salt Water Injection Well No Violations 1501:9-3-04 PREVENT CONTAMINATE
000UIC1806 1999-10-25 Salt Water Injection Well No Violations 1501:9-3-05 (6) B(7) CONSTURCTION
001289i502 2002-07-08 Salt Water Injection Well No Violations NO CHANGE IN STATUS OF WELL , NO FURTHER WORK DONE ON WELL OR FACILITIES TO PUT WELL BACK INTO PRODUCTION.
0079739624 2013-12-06 Salt Water Injection Well No Violations On site to witness pressure testing on annulus of tubing company personnel applied 700 psi to annulus and we monitored pressure for 15 minutes with no decline in pressure and we left 500 psi on annulus.
0108772901 2007-02-23 Salt Water Injection Well No Violations No violations noted, well is still down for repair(replace/repair back wall on unloading pad) told well owner not to use facility until repairs could be made,also old vault tank still needs to be removed from site.
0123371581 2003-10-17 Salt Water Injection Well No Violations No violations noted.

(3)old tanks need to be removed and also all of old flowlineneeds gathered up. (4)Need to close end of dike before putting well into operation (11)sidewalls on unloading pad need to be higher. Contact inspector prior to working on

0149525708 2008-05-12 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Old vault is still in need of removal from site along with old storage tanks,also water in dike area needs to be pumped up into tanks and properly disposed of in well also piping from unloading pad drain needs to be resealed!

0201115653 2014-08-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during our inspection and we measured dike dimensions to verify volumes in the event of catastrophic tank failure.
0228434719 2007-01-31 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted back retaining wall on unloading pad had been breached went to company office and discussed shutting well down until repairs can be made to unloading pad wall company rep noted my suggestion. also pressure will need to be placed on annulus of tubing before placing well back into operation.

0290691873 2017-02-13 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0300584451 2007-05-03 Salt Water Injection Well No Violations No violations noted, facility is down for repair of unloading pad company driver knocked back wall down due to faulty brakes on company owned truck.

Note: Old vault still needs to be removed from site also old tanks etc..

0321961501 2008-11-28 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation today noted that injection pump is in need of repair,and also old vault is still in need of removal from site and also old storage tanks need to be removed also.
0355377536 2017-06-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.


Note: One company owned vacuum truck was unloading at the facility during my inspection.

0360684503 2004-10-27 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Old vault &tanks needs to be removed from site.

0478561527 2006-07-19 Salt Water Injection Well No Violations No violations noted,on site to witness mini test on annulus of tubing, company rep Troy Green pumped fresh water &anhib in annulus brought presure up to 225 psi and monitored pressure for 15 min with no decline in pressure(TEST PASSED).
0483471391 2008-12-23 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Old vault&tanks needs to be removed from site and vegetation needs to be established below tank area!

0513540774 2006-03-31 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Well does not appear to used much,operator still needs to remove old tanks from site and properly dispose of old vault and remove lounge chair from pump area. Note: Housekeeping needed in unloading area clean up around filter housing container,possibly could use more stone on lease road to unloading pad area.

0529603253 2004-08-05 Salt Water Injection Well No Violations No violations noted,facility in satisfactory condition this inspection.

(5)sealant needed@unloading pad drain tank. OLD VAULT STILL NEEDS TO BE REMOVED FROM SITE!!!!!!!!.

0530711387 2007-09-04 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition,noted that company has not installed catch pan below pump to catch brine from leaking pump so it does not leak out within dike area talked to well tender several weeks ago about this problem and he stated that he would tell supervisor and have pan constructed&installed under pump before placing well in use.
0546983537 2014-03-27 Annular Disposal Violations Noted This was an injection well inspection. The injection pump to this well was not in operation. The annulus tested at 560psi and the injection tubing tested at 158psi. There are two dikes at location and both have oil and brine contamination. Operator must remove and properly dispose of contamination.
0550597980 2008-06-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Old vault still needs to be removed from site along with old storage tanks and also better vegetation needs to be established below pump area.

0553021839 2006-01-25 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Request that operator place pressure on annular space between casing and tubing to conform to Ohio Administrative Code1501:9-3-07(7).Inspector want to be present when pressure is applied.

0553795798 2013-04-24 Salt Water Injection Well No Violations On site to witness pressure testing of annulus of tubing on said well they pressures up to 340 psi and we monitored pressure for 15 minutes with no decline in pressure .

Note: Exposed portion of liner in tank area needs to be properly covered with stone to prevent it from rotting due to exposure to sunlight.

0570811291 2004-11-30 Salt Water Injection Well No Violations No violations noted on the day of my inspection,facility doesnt appear to be used much.

Fresh water needs removed from dike area. Old vault still needs to be removed from site and after removal site needs reclaimed and vegetation established.

0576867572 2015-03-04 Salt Water Injection Well No Violations Well was not in operation during my inspection and it was noted that stone has been placed in road to unloading pad as requested on previous inspection.
0608948256 2007-07-02 Salt Water Injection Well No Violations Met with company reps to perform mini-test on annulus of tubing started to pressure up and noticed 2 valve leaking on seal ring attempted to tighten it up with no success suggested that valve would need to be replaced they did so and we proceeded to pressure up on annulus tested at 500 psi for 15 min with no decline in pressure, discussed placing catch pan under injection pump before placing well back into operation well operator took measurements and stated that he would inform his supervisor of things needed done before placing well back into operation.
0623435037 2004-09-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(4) Fresh water needs removed from dike area to allow for capacity in the event of spill. Old vault still needs removed from site as to per phone conversation. Need to place trash can at site to place filters and other trash.

0624023431 2012-03-09 Salt Water Injection Well No Violations My inspection this day due to quarterly requirements - pump was running this day and well tested 300# on tubing, 0# on annulus. Brine truck on location as I was leaving. Identification is good as posted, water is inside the dike area and I will write citation if it is still there at next inspecdtion.
0624281182 2013-01-31 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that there was large volume of fresh water build up in tank area told operator to have water removed from area and place it in tanks and properly dispose of it down the well.
0631385714 2015-01-15 Salt Water Injection Well No Violations The pumps were inactive upon inspection. Broadstreet has leveled and graveled the access road as requested by inspectors. There are no issues to report at this time.
0655632432 2004-01-27 Salt Water Injection Well No Violations No change in status since last inspection,facility still under construction awaiting better weather conditions before resuming work on facility.
0684225442 2004-09-27 Salt Water Injection Well No Violations No violations noted ,facility appears to be in satisfactory condition this inspection.

Pump down for repair on the day of my inspection. Due to recent rainfall it appeared that wellhead was under flood water,would like operator to remove old storage tanks from site before they become potential pollution&contamination violations.

0730922733 2016-05-05 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0741057799 2009-02-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection, noted that 1-210 bbl tank within dike area had oil staining on the side of it and I suggested to well tender that it needed to be cleaned as weather permits also told him that positive pressure needed to be applied to annulus of tubing, told well tender call me prior to applying pressure I wanted to be present at site during pressure check.
0760036727 2004-04-15 Salt Water Injection Well No Violations Facility still under reconstruction pump being set south end of dike wall still needs to be closed@tank site,old vault still needs to be emptied hauled away and site reclaimed.

Will need to pressure test flowline and recheck integrity of tubing/packer before placing well into operation,old tanks also needs to be removed from site.

0781138854 2014-03-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that water within dike area is building up and needs to be removed ASAP.

Note: Annulus of tubing needs positive pressure applied.

0829435269 2005-05-11 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Fluid end has been placed back on pump since my last inspection,also someone is filling old vault with fluid,had verbal agrement with company to discontinue use of vault fearing it might leak.

0843108839 2019-03-04 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it appears that wells are not being used much at this time, main gate to facility locked and no evidence of truck traffic.
0855458174 2003-07-09 Salt Water Injection Well Violations Noted Facility in need of repair!

2no Idat well head 4 end of dike needs closed 5 vault has cracks in it on back wall(leaking salt water+oil large kill area below vault, 11Cracks in unloading pad,suggest reconstruction. Suggest empty vault and remove all contaminated soil and replace soil +seed+mulch.

0858413286 2004-12-21 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.Well does not appear to be used much.In conversation with Troy Green about removing old tanks&removing old vault at site with no results.
0893927087 2006-09-14 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection,noted small kill area below dike area contacted well owner and inquired about it she stated that she would have Troy Green clean up affected area ASAP told her that inspector needed to be notified when clean up was complete,company owned truck was unloading at facility during my inspection unloading pad in need of housekeeping and plumbing on filter housing in need of repair and hoses on water truck in need of replacement.
0933826890 2004-04-12 Salt Water Injection Well No Violations Well still under construction was informed by Mr.Green that pump was purchased and is awaiting too be mounted and set into place advised company rep that old vault would need to be addressed when equiptment was near by(removed and hauled to EPAapproved landfill)end of tank dike will need to be closed also
0960452135 2006-12-19 Salt Water Injection Well No Violations Inspesction revealed that operator needs to apply pressure to annulus of tubing,pump was not in operation today noted scald area below dike area notifyed company of cleanup needed at site told them to remove contaminated soils and apply lime&fertilizer&seed&mulch to affected area to establish vegetation,Suspect possible pump leakage source of brine instructed them too remove drain from dike and repair liner.
0995343306 2003-09-03 Salt Water Injection Well No Violations I.D.needs to be posted at wellhead

Contact inspector prior to working on well. Suggest removing old production tanksfrom old pad site

1053325317 2011-07-12 Salt Water Injection Well No Violations inspection this day found pump running, pressure on tubing at well 550#, pressure on annulus is 50#. J & L on location, dumping brine - brine no on truck.. Well receiving 400 bbl this day which they said was unusual. Huge rains last night and dike area full of water, will pumped out soon as there is room.
1075814213 2016-03-04 Salt Water Injection Well No Violations Injection pump was in operation during my inspection and it was noted that there used filters were in need of being removed from site and hauled to a approved landfill.
1079095427 2004-03-10 Salt Water Injection Well No Violations

Facility still under construction no violations noted. (6)unable to check pressure(due to bad valve) (4)dike wall will need to be constructed before putting well into service. (9)still needs pump (11)unloading pad side walls need to be higher Note old vault needs to be emptied and cease use(walls are showing signs of seepage).

1088162371 2004-06-21 Salt Water Injection Well No Violations Dike wall has been constructed since last inspection,injection pump installed operator still needs to run flowline to well head and preform pressure test on annulus to recheck integrity of tubing and packer,also stone needs to be placed on liner to help prevent it from rotting.Facility still under reconstruction.
1089563238 2004-07-09 Salt Water Injection Well No Violations Facility under reconstruction on site to pressure test annulus of well to check integrity of tubing&packer.TEST PASSED.held 700psi for 15min with no decline in pressure.Attempted to pressure test flowline pressured up to 700psi and pressure declined to 500psi flowline test failed,walked flowline and found hammer union leak and one thread leak instructed operator to repair line and tighten union will test again at later date.23/8 upset tubing used as flowline.
1090089608 2004-07-12 Salt Water Injection Well No Violations On site to pressure test flowline and witness closing of dike wall to insure proper instalation.

Pressured tested line at 950psi TEST PASSED Conversation with Troy Green concerning old vault tank that needs to be removed from site agreed to remove from site within 6 months from todays date.

1113610728 2005-04-11 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Fluid end removed from pump apparently down for repairs. Old vault has fluid back in it, it was discussed some time ago that vault was not to be used for brine storage due to fact that walls have cracks in them showing signs of seepage.

1113765494 2011-12-01 Salt Water Injection Well No Violations Inspection this day found pump running. There was 60 PSI on the tubing and 0 PSI on the annulus. There was an oily residue inside the dike area and it appears that have been working on cleaning it up. Proper identification posted at the well, all else satisfactory.
1119746327 2005-06-23 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Old vault has been emptied since my last inspection. Noted:Tanks on production well located at site has been changed,need to remove old tanks ASAP.

1150492599 2006-06-12 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

Need to apply pressure to annulas on tubing contact imspector prior to doing so (need to be present to monitor pressures).

1152888496 2006-07-10 Salt Water Injection Well No Violations On site to witness mini-testing of annulus of tubing, company rep Troy Green attempted to apply pressure to annulus with small pump with no luck it appeared that pump was in need of repair, told Mr. Green to have pump rebuilt and call to reschedule testing.
1157975392 2018-01-28 Salt Water Injection Well No Violations Injection pump not in operation today.

Housekeeping needed in pump area.

1164702827 2005-11-25 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Need to apply pressure to annulus of tubing,contact inspector prior too doing so he may witness job.

1182981422 2007-06-25 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.
1193345697 2007-10-22 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: In conversation with company rep stating that catch pan beneath pump is nearly completed once completed they will have it installed under pump,vegetation still needs to be established below dike area and also old storage vault needs to be removed from site and old storage tanks need to be removed from site.

1204384962 2005-02-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Well does not appear to be used much. (11) Stone needed on road to unloading pad.(5)Old vault still needs removed from facility,and also old adbandoned tanks. Pump not running today.

1207646107 2008-02-25 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Old vault is still in need of removal from site along with old storage tanks,fresh water within dike area in need of being pumped into tanks for proper disposal.

1219962808 2008-08-28 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition this inspection, noted company owned vac truck was unloading at site during inspection.

Note: Water within tank area needs to be pumped up into tanks and small tank that catches unloading pad water needs to be pumped into tanks also,do not drain over the hill water is brine/oil laden suggest placing sump pump within tank area to control water evel also noted number two cylinder on injection pump is in need of repair,also old vault and old storage tanks need to be removed from site.

1235439230 2008-03-19 Salt Water Injection Well No Violations No violations noted, facility appeared to be in satisfactory condition this inspection.

Note: Pump was not running during my inspection, noted that 2 valve on annulus side of well head needs to be replaced it apparently froze and parted during cold weather owner will need to replace valve and reapply pressure to backside of tubing contact inspector prior to doing so (he needs to be present when applying pressure to annulus.

1259021906 2014-04-29 Salt Water Injection Well No Violations Grass is starting to grow around the area of previous contamination. There are no issues to report at this time.
1260836502 2009-12-14 Salt Water Injection Well No Violations Follow-up on NOV, In-Compliance.
1272961744 2014-04-02 Salt Water Injection Well No Violations UIC inspector Dave Ball and I met up at injection well site to go over the dike and well issues. There was still contamination within the dike. I will meet Kenny OBrian tomorrow to go over dike issues and to test the annulus on both injection wells prior to further operation.
1289i24153 2001-05-24 Salt Water Injection Well No Violations SWIW, NO VIOLATIONS. WELL STILL IDLE.
1289i24153823 2001-5-24 0:00: SW No Violations
1289i26057 2002-04-04 Salt Water Injection Well No Violations WELL STILL UNDER CONSTRUCTION. LINES NEED INSTALLED, PUMP NEEDS MOVED IN AND SET UP. OLD EQUIPMENT ON FACILITY NEEDS TORN DOWN AND HAULED OUT.
1289i26057890 2002-4-4 0:00:0 SW No Violations
1289i502 2002-7-8 0:00:0 SW No Violations
1345332553 2012-08-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Old vault still needs to be emptied and removed from site and hauled to a approved landfill and stone needs to be placed on exposed portion of pit liner in storage tank area.

1371451008 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED
1386625296 2013-12-06 Salt Water Injection Well No Violations On site to witness pressure testing on annulus of tubing to verify that they have good casing integrity, company reps applied 500# of pressure and we monitored pressure for 15 minutes with no decline (TEST PASSED).
1396544572 2014-04-03 Salt Water Injection Well No Violations I met up with Kenny OBrien to witness a mechanical integrity test on annulus of tubing to verify that they have good casing integrity. They loaded up the annulus and held the maximum of 700psi for 15 minutes with no decline in pressure (PASSED).
1397841682 2012-08-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Old vault has been emptied and removed from site and area has been graded and seeded and mulched and I suggested that exposed portion of dike line be covered with stone once back wall of dike is built up to standard and covered.

1422153085 2017-09-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one company owned vacuum truck was unloading at the facility during my inspection.
1491438385 2008-07-17 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Weed eating a path to well head would be helpful,also housekeeping in pump area needed and old vault&tanks still need to be removed from site!

1535739619 2018-08-30 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.

Note: Gate was locked at the entrance apparently well is not being used much at this time.

1541944545 2015-11-24 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was in operation,
1557278331 2008-02-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection also old tanks and vault still needs to be removed from site and unloading pad drain tank needs to be KEPT EMPTY and unloading pad is getting prett messy it needs a good cleaning when weather permits.

1573333687 2018-04-08 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted that fresh water has built up in containment area and I called company rep Chuck Woods and told him to get water pumped into storage tanks and properly dispose of it down hole.
1631226014 2020-2-25 0:00: SW No Violations
1659229813 2009-06-04 Salt Water Injection Well Violations Noted An inspection of the well revealed oily material in dike of storage tanks. Appears tanks have over flowed, oily gravel needs cleaned up and removed from dike area and clean gravel installed. ID need rewrote on stickers, at well head and storage tanks, starting to fade.
1751574035 2005-09-26 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted: Painting has occurred at unloading pad area! Old vault still present needs to be removed from site and also old tanks at site needs to be removed.

1770445785 2006-07-31 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection, on site to recheck annulus of tubing to confirm that pressure was holding .
1774252687 2013-09-20 Salt Water Injection Well No Violations Inspection revealed that annulus pressure has dropped to zero and I called company rep Ed Butler and requested that he make arrangement to have pressure applied ASAP.
1780806901 2007-03-08 Salt Water Injection Well No Violations No violations noted well is stil down for repair of back wall on unloading pad owner will need to pump water that has accumulated in dike area into storage tank it has small traces of oil noted within dike areaa and around pump area,
1783788130 2013-10-04 Salt Water Injection Well No Violations Met with contractor Jeff Jones on site to discuss getting remaining portion of exposed liner covered with stone to help prevent damage caused from UV RAYS.
1818245206 2014-08-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one J&L Water Service vacuum truck was unloading at facility during my inspection.
1825744289 2018-05-21 Salt Water Injection Well No Violations Well not in operation at this time.

Note: Gate has been installed at entrance to lease road.

1830573025 2015-01-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection but water was being pumped into the other injection well on the lease.
1844755307 2012-06-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Old vault tank needs to be emptied and vault removed from site and stone needs to be applied to liner in tank area to help prevent decay due to exposure to sunlight and it appears that storage tanks overflowed at some point in time and more clean up in this area is needed.

1846908563 2016-11-01 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that valve too the 4658 well was also open fluid from pump was being pumped to both wells on the lease.
1863655782 2013-03-12 Salt Water Injection Well No Violations I accompanied Dave Ball on the inspection and testing of UIC well. The pump was running at the time of arrival and J & L Company was unloading brine at docking station. There are three 210 barrel tanks at location.
1865129712 2017-02-28 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2016. Please submit the appropriate reports by March 14, 2017. reports received 5/16/2017
1867466501 2007-11-15 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection,pump was not in operation on the day of my inspection.

Noted that company personnel was on site attempted to clean up small amount of oil from leaking tank,suggested too them that old storage tanks at site needed to be removed from site and also old vault tank also needs to be removed from site.

1909875480 2005-12-20 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.Well does not appear to be used much noticed that stone is needed in driveway to unloading pad.

Note: Will need to apply pressure to annulus of tubing,contact inspector prior to doing so!

1934481192 2018-12-10 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.


Small amount of fresh water build up in dike area, will call company rep and request that they properly remove fluid from dike area.

1987342447 2007-08-02 Salt Water Injection Well No Violations No violations noted, facility in need of repair in pump area as discussed earlier containment area under pump needed before placing well into operation, pump leaks in packing and swab area allowing brine within dike area it appears that operator is still using facility also old vault is still in need of removal and old storage tanks need to be removed from site.
1994779986 2017-04-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that fresh water needs to be removed from dike area to allow for volumes in the event of a spill.
2005854757 2014-04-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today due to fact that fluid end on pump has been removed and is being repaired.

Note: Local inspector Jake Glasscock will perform integrity test on annulus of tubing 4/3/2014.

2035998772 2008-09-29 Salt Water Injection Well No Violations Inspection revealed that pump was not operating during my inspection, noted oil within dike(photos taken) went to company office and requested that clean up begin immediately and that I would be back at site to check on compliance, also old vault still needs to be removed from site along with old storage tanks, and vegetation needs to be established below pump area.
2078058098 2013-03-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one J&L Hauling vacuum truck was unloading at facility during our inspection.

Note: Told operator that they would have to have positive pressure applied to backside of tubing and contact inspector prior to doing so.

2114289015 2007-12-24 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump was not in operation during my inspection, also walked flow line area to monitor for potential leaks none found).Old vault is still in need of being removed along with old storage tanks at site.

2115263678 2003-12-08 Salt Water Injection Well No Violations No violations noted,facility still under construction.

(4)dike end still needs closed (9)still need pump,flowline hooked up. Will need to pressure checked after installation (11)unloading pad side walls need to be higher and sealed drain line from unloading pad to tank also needs sealed up.

290691873 2017-2-13 0:00: SW No Violations
300584451 2007-5-3 0:00:0 SW No Violations
321961501 2008-11-28 0:00 SW No Violations
355377536 2017-6-29 0:00: SW No Violations
360684503 2004-10-27 0:00 SW No Violations
478561527 2006-7-19 0:00: SW No Violations
483471391 2008-12-23 0:00 SW No Violations
513540774 2006-3-31 0:00: SW No Violations
529603253 2004-8-5 0:00:0 SW No Violations 1.00
530711387 2007-9-4 0:00:0 SW No Violations
553795798 2013-4-24 0:00: SW No Violations 3.00
570811291 2004-11-30 0:00 SW No Violations
655632432 2004-1-27 0:00: SW No Violations 1.50
858413286 2004-12-21 0:00 SW No Violations
890738750 2020-7-28 0:00: SW No Violations
995343306 2003-9-3 0:00:0 SW No Violations
iTOMK00007 2000-08-03 Salt Water Injection Well No Violations SWIW#11
iTOMK000076 2000-8-3 0:00:0 SW No Violations
PL9866 PL No Violations
UIC100 1987-3-17 0:00: SW No Violations
UIC1210 1992-1-7 0:00:0 SW No Violations
UIC1211 1992-1-7 0:00:0 SW No Violations
UIC1529 1994-9-27 0:00: SW No Violations
UIC1805 1999-10-25 0:00 SW No Violations
UIC1806 1999-10-25 0:00 SW No Violations
UIC293 1987-3-17 0:00: SW No Violations
UIC470 1987-10-1 0:00: ER No Violations
UIC471 1987-10-1 0:00: SW No Violations
UIC520 1988-3-24 0:00: SW No Violations
UIC521 1988-3-24 0:00: SW No Violations
UIC522 1988-3-24 0:00: SW No Violations
UIC709 1989-6-13 0:00: SW No Violations
UIC829 1989-12-19 0:00 SW No Violations
UIC830 1989-12-19 0:00 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
000UIC1529 US-OH-131705 Failure to monitor annulus pressure
0546983537 US-OH-126017 2015-01-08 Pollution/Contamination
0855458174 US-OH-129753 2003-07-12 Pollution/Contamination
0855458174 US-OH-129754 2003-07-12 Permit not displayed
0855458174 US-OH-129755 2003-07-12 Pits not liquid tight/Improper construction or use
1371451008 US-OH-110779 2016-04-15 Failure to file salt water injection annual report
1659229813 US-OH-116395 2009-06-08 Failure to legibly identify well
1659229813 US-OH-116396 2009-06-08 No SPCC dike/or failure to keep dike free of water or oil
1659229813 US-OH-116397 2009-06-08 Pollution/Contamination

For data sources see[9]