If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-23010 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.66,"lon":-81.75,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: Meigsville Township | |
Operator Name: HOCKING HILLS ENERGY AND WELL | |
Well Pad ID: | |
Farm/Lease Name: KNAPP GERALD E | |
License Status: Producing | |
License Date: 1982-11-24 | |
Spud Date: 1983-03-17 | |
Spud Drilling Contractor: IRVIN DRLG | |
Final Drill Date: | |
Well Total Depth: 0.00 ft | |
Configuration: Vertical | |
Latitude: 39.660000 | |
Longitude: -81.750000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-11-24 | 1138 BRISTOL PRODUCTIONS INC GeoDate 11/24/82 |
Oil and Gas | 1982-11-24 | Issued Date 11/24/82 Expired Date 5/23/83 Acres 0040000 Tool Type CRA Proposed Formation MEDINA Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1983-03-17 | PERMIT EXPIRED. |
Construction Permit Expires | 1983-05-23 | PERMIT EXPIRED. |
Change of Owner | 2006-05-05 | Operator changed from 1138, BRISTOL PRODUCTIONS INC to 7077, D T ATHA INC |
Change of Owner | 2013-07-16 | Operator changed from 7077, D T ATHA INC to 4260, CORTLAND ENERGY CO INC |
Change of Owner | 2015-06-19 | Operator changed from 4260, CORTLAND ENERGY CO INC to 5755, HOCKING HILLS ENERGY WELL SERV |
Record Last Modified | 2015-09-24 | PERMIT EXPIRED. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | REDMAN OIL CO INC | 15650.00 | 0.00 | 0 |
1985 | REDMAN OIL CO INC | 10835.00 | 0.00 | 0 |
1986 | REDMAN OIL CO INC | 5654.00 | 0.00 | 365 |
1987 | BRISTOL PRODUCTIONS INC | 0.00 | 0.00 | 0 |
1991 | BRISTOL PRODUCTIONS INC | 0.00 | 0.00 | 0 |
1992 | BRISTOL PRODUCTIONS INC | 0.00 | 0.00 | 365 |
1993 | BRISTOL PRODUCTIONS INC | 0.00 | 0.00 | 365 |
1994 | BRISTOL PRODUCTIONS INC | 0.00 | 0.00 | 365 |
1996 | OHIO PRODUCTION CORP | 13935.00 | 0.00 | 144 |
1997 | OHIO PRODUCTION CORP | 3166.00 | 0.00 | 72 |
1998 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
1999 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2000 | OHIO ENERGY ASSETS, INC. | 7194.00 | 0.00 | 275 |
2001 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2002 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2003 | BRISTOL PRODUCTIONS INC | 2287.00 | 0.00 | 58 |
2004 | HOUGHTON INVESTMENTS LLC | 1994.00 | 0.00 | 365 |
2005 | HOUGHTON INVESTMENTS LLC | 1756.00 | 0.00 | 365 |
2006 | RIVER VALLEY ENERGY INC | 3055.00 | 0.00 | 365 |
2007 | HOUGHTON INVESTMENTS LLC | 4404.00 | 0.00 | 365 |
2008 | HOUGHTON INVESTMENTS LLC | 4411.00 | 0.00 | 365 |
2009 | HOUGHTON INVESTMENTS LLC | 6668.00 | 0.00 | 365 |
2010 | HOUGHTON INVESTMENTS LLC | 7950.00 | 0.00 | 365 |
2011 | HOUGHTON INVESTMENTS LLC | 3142.00 | 0.00 | 365 |
2012 | RIVER VALLEY ENERGY INC | 0.00 | 0.00 | 366 |
2013 | RIVER VALLEY ENERGY INC | 0.00 | 0.00 | 365 |
2014 | CORTLAND ENERGY CO INC | 0.00 | 0.00 | 0 |
2017 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1281501573 | 2003-2-21 0:00: | PW | No Violations | |
-567573004 | 2013-7-11 0:00: | PW | No Violations | 3.00 |
-83277509 | 2014-12-1 0:00: | PW | No Violations | 0.30 |
-866838013 | 2003-2-20 0:00: | PW | No Violations | |
0000PL9843 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0083277509 | 2014-12-01 | Production Wells | No Violations | Bob Masters has installed some new lines and new drips at the tank battery location. They are trying to cleanup the well and the lines in order to get the gas into Artexs transmission line. The well and tank battery have recently been cleared of vegetation. |
0253848123 | 2017-11-03 | Production Wells | Violations Noted | I was on location today to do a field inspection on this well. The well appears to be in production at this time but I was unable to locate any identification for this well. The well by law must have legible identification located at either the well or the production tank. If there is more then one well producing into the same production tank the identification is required to be on both the well and the production tank. The identification must have the following, owner, well name, well number, permit number, township, county and emergency contact number. You will have 10 days to correct the violation and get the identification on either the well or the tank pad. I was able to contact Hocking Hills Energy to let them know about the violation today. Doug Stated he would get the violation resolved in the 10 days given. |
0567573004 | 2013-07-11 | Production Wells | No Violations | Dave Ball and I met Paul Withers at the well location to discuss the leaking casing issues. He had used a backhoe to dig out around the casing several feet deep. Gas was bubbling out of the side where there was a casing clamp. It was determined that a service rig would have to come into location and they would have to get a wellhead on the casing and pull the tubing in order to see how deep the well was and the condition of the packer. RBDMS records only show that the 7 was mudded with 10 sacks of fireclay at 1678. The proposed depth was 5000 and there is a history of H2S with this well. Paul said Lee Atha will call me to let me know when they plan on moving to the location.. |
0866838013 | 2003-02-20 | Production Wells | No Violations | WELL IS IDLE, STRONG SMELL OF H2S STILL PRESENT. |
1051616370 | 2003-04-28 | Production Wells | No Violations | Well in compliance to N.O.V.#23450,well is in production and not venting H2Sgas. |
1281501573 | 2003-02-21 | Production Wells | Violations Noted | upon inspecting well site found well to be idle,strong presence of H2S gas around well head possible hole in casing.well back into production. |
1372874385 | 2013-07-03 | Production Wells | Violations Noted | Upon inspection, I found the wellhead to be leaking gas from the surface casing somewhere around ground level. There was an audible sound and the gas detector alarm went off for methane as I was standing near wellhead. There is an H2S smell around the wellhead as well as the tank battery up by the road. This tank battery has two 1500 gallon plastic tanks and 4 separators. There is a meter with no chart and everything appears to be shut in. There are no other wells listed in RBDMS in this area. There is another 1500 gallon tank and a small shed straight up from the wellhead by the road, and the shed has a drum full of fluid. Everything is completely overgrown in this area. There is no identification posted for this well. I spoke with Bob Atha and he stated they will have someone out there soon to take care of the issues. He said the well was in the process of being transferred over to someone with Cortland Energy. Operator must post proper id. Operator must fix casing leak and make well capable of production within 30 days; or plugging is required in 30 days. |
1373976429 | 2013-07-16 | Administrative Inspection | No Violations | I talked with Bob Atha and he and Lee Atha are trying to line up a service rig with the hopes of getting the issues resolved before the middle of August. They will call me in order to inform me when they will be on location with the service rig. |
1375810331 | 2013-08-06 | Production Wells | No Violations | Compliance action follow-up 1372874385: I met with Lee Atha and he had put plugs on the wellhead with a gauge. The wellhead pressured up and held 250 psi and there was no evidence of any leak in the casing. He is going to contour out around the wellhead and leave the excavated area exposed should there be any issues in the future. He is also going to send me all of the missing records for this well and the Van Horne #2 down the road. Cortland Energy is now the owner of the well. |
1904210149 | 2018-01-24 | Production Wells | No Violations | I was on location today to do a follow-up inspection on this well. The well is now in compliance with the identification at the tank pad. |
253848123 | 2017-11-3 0:00: | PW | No Violations | 1.00 |
PL9843 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0253848123 | US-OH-122615 | 2018-01-31 | 9-9-05(A)10 | Failure to legibly identify well |
1281501573 | US-OH-107815 | 2003-02-23 | Well insufficiently equipped to prevent escape of oil and gas | |
1281501573 | US-OH-107816 | 2003-02-23 | Failure to legibly identify well | |
1281501573 | US-OH-107817 | 2003-02-23 | Well shall be plugged | |
1372874385 | US-OH-111054 | 2013-08-06 | General Safety | |
1372874385 | US-OH-111055 | 2013-08-06 | Well insufficiently equipped to prevent escape of oil and gas | |
1372874385 | US-OH-111056 | 2013-08-06 | Failure to legibly identify well | |
1372874385 | US-OH-111057 | 2013-08-06 | Equipment pressure rated below operating pressure |
For data sources see[7]