If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-24023 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.75,"lon":-81.98,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: York Township | |
Operator Name: TEMPLE OIL & GAS CO | |
Well Pad ID: | |
Farm/Lease Name: FYE GEORGE | |
License Status: Producing | |
License Date: 2003-08-25 | |
Spud Date: 2004-01-02 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 2004-04-02 | |
Well Total Depth: 1406.00 ft | |
Configuration: Vertical | |
Latitude: 39.750000 | |
Longitude: -81.980000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-05-21 | 79 OXFORD OIL CO GeoDate 5/21/87 |
Oil and Gas | 1987-05-21 | Issued Date 5/21/87 Expired Date 5/20/88 Acres 0159750 Tool Type CRAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1991-11-26 | 79 OXFORD OIL CO GeoDate 11/26/91 |
Oil and Gas | 1991-11-26 | Issued Date 11/26/91 Expired Date 11/25/92 Acres 0159750 Tool Type CRAF Proposed Formation BEREA Proposed Depth Proposed Drill Depth |
CO | 1993-03-04 | 79 OXFORD OIL CO GeoDate 3/4/93 |
Oil and Gas | 1993-03-04 | Issued Date 3/4/93 Expired Date 3/4/94 Acres 0159750 Tool Type CRAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
Completed | 1995-12-19 | RBDMS Rec |
Change of Owner | 2000-08-16 | Operator changed from 79, OXFORD OIL COMPANY to 384, TEMPLE OIL & GAS CO |
APP | 2000-08-17 | Proposed Formations:BEREA, Issued Date:8/17/00, Expired Date:8/17/01 6:00:00 AM, Drilling unit acres:159.75, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2003-08-25 | Proposed Formations:BEREA, Issued Date:8/25/2003, Expired Date:8/24/2004 6:00:00 AM, Drilling unit acres:159.75, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-01-02 | RBDMS Rec |
Reached Total Depth | 2004-04-02 | RBDMS Rec |
Construction Permit Expires | 2004-08-24 | RBDMS Rec |
Completion Report Received | 2005-09-30 | RBDMS Rec |
Record Last Modified | 2015-09-24 | RBDMS Rec |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
Not Treated | 0 | 0 | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | TEMPLE OIL & GAS CO | 0.00 | 116.00 | 344 |
2007 | TEMPLE OIL & GAS CO | 0.00 | 45.00 | 313 |
2008 | TEMPLE OIL & GAS CO | 0.00 | 161.00 | 365 |
2009 | TEMPLE OIL & GAS CO | 0.00 | 69.00 | 261 |
2010 | TEMPLE OIL & GAS CO | 0.00 | 100.00 | 313 |
2011 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 365 |
2012 | TEMPLE OIL & GAS CO | 0.00 | 226.00 | 366 |
2013 | TEMPLE OIL & GAS CO | 0.00 | 171.00 | 365 |
2014 | TEMPLE OIL & GAS CO | 0.00 | 92.00 | 365 |
2015 | TEMPLE OIL & GAS CO | 2.00 | 102.00 | 365 |
2016 | TEMPLE OIL & GAS CO | 0.00 | 77.00 | 365 |
2017 | TEMPLE OIL & GAS CO | 0.00 | 87.00 | 365 |
2018 | TEMPLE OIL & GAS CO | 0.00 | 108.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | TEMPLE OIL & GAS CO | Brine | 1281 | 344 |
2007 | TEMPLE OIL & GAS CO | Brine | 1059 | 313 |
2008 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2009 | TEMPLE OIL & GAS CO | Brine | 0 | 261 |
2010 | TEMPLE OIL & GAS CO | Brine | 1872 | 313 |
2011 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2012 | TEMPLE OIL & GAS CO | Brine | 2068 | 366 |
2013 | TEMPLE OIL & GAS CO | Brine | 1952 | 365 |
2014 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2015 | TEMPLE OIL & GAS CO | Brine | 2187 | 365 |
2016 | TEMPLE OIL & GAS CO | Brine | 1223 | 365 |
2017 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2018 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1093267429 | 2015-12-7 0:00: | PW | No Violations | |
-1483293946 | 2017-2-13 0:00: | PW | No Violations | 1.00 |
-1545445783 | 2017-1-4 0:00:0 | PW | No Violations | 1.00 |
-1663976072 | 2017-3-13 0:00: | PW | No Violations | 2.00 |
-2090987979 | 2016-10-4 0:00: | PW | No Violations | 2.00 |
0254140592 | 2015-08-24 | Production Wells | No Violations | I returned to this well to do a follow-up inspection on it. The well is still currently idle and incapable of production. The valves are shut at the well with no production equipment on location. The well is still in violation. |
0674882795 | 2009-11-10 | Preliminary Restoration | No Violations | Restoration meets 1509.072(A) requirements. |
1073737480 | 2004-01-09 | Drill / Deepen / Reopen | Violations Noted | Stopped by cable tool rig to check on status of well for upcoming surface job they were drilling ahead @135 encountered water @50 spudded well 1-2-04 went by rig for update no one present 8 in place no one called inspector prior to running casing or mudding of said casing. |
1093267429 | 2015-12-07 | Production Wells | No Violations | I returned to this well to do a follow-up inspection on it. The well now has a pumping unit on the well and is in operation. The well was pumping during the time of my inspection. There are no violations at this time. |
1435672041 | 2015-06-30 | Production Wells | Violations Noted | I was at this well to do a field inspection on it. During my inspection I found the well is idle and not capable of production. The production equipment has been removed from the well and the valves are shut at the wellhead making in incapable of production. The well is in violation and will need to be plugged within 180days. |
1483293946 | 2017-02-13 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 2 inch diameter production lines, and 1 1/2 inch diameter production lines. All the valves are open on the wellhead at the time of inspection. The tank battery for this well is equipped with two (2) 100 barrel steel tanks and a 50 barrel plastic tank. There is proper identification on the tanks for this well. There are no issues to report at this time and the well is currently in production at the time of inspection. |
1545445783 | 2017-01-04 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 2 inch steel and plastic production lines, and 1 1/2 inch diameter production tubing. The well currently has the valves open on the wellhead and, the pumping motor currently has electric hooked up to it from the electric box at the well. There is identification at the well that has been written on the electric box with all pertinent information. The tank battery for this well is equipped with two (2) 100 barrel steel tanks and a 50 barrel plastic tank. The tank battery is a shared battery with identification for each well going to it. The well is currently producing at the time of inspection and the issue with this well has been resolved. |
1587793272 | 2016-11-23 | Production Wells | Violations Noted | The inspection revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 1 1/2 inch diameter production tubing, and 2 inch diameter steel production lines. The polish rod on the pumping unit was slightly tarnished but looks to have been used recently. The valves on the wellhead and lines are all open. The well has electricity hooked up to the electric timer near the well for the electric motor and a belt on the motor. The tank battery is equipped with two 210 barrel tanks and a separator. The tanks have 4 wells leading to it. The wellhead did not have any identification on it and when having multiple wells going to a single tank battery each wellhead must have separate identification on it. |
1663976072 | 2017-03-13 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 2 inch diameter production lines, and 1 1/2 inch diameter production lines. All the valves are open on the wellhead at the time of inspection. The tank battery for this well is equipped with two (2) 100 barrel steel tanks and a 50 barrel plastic tank. There is proper identification on the tanks for this well. There are no issues to report at this time and the well is currently in production at the time of inspection. |
2090987979 | 2016-10-04 | Production Wells | No Violations | On my inspection today I was accompanied by inspector Eric Conrad. The inspection revealed that this well is equipped with a 4 1/2 inch diameter well head, 1 1/2 inch diameter production tubing, 2 inch diameter steel production lines, and 2 inch diameter plastic production lines. The well had all production valves open at the time of inspection. The tank battery was equipped with 2 100 barrel tanks and a 1600 gallon plastic brine tank. |
254140592 | 2015-8-24 0:00: | PW | No Violations | 1.00 |
674882795 | 2009-11-10 0:00 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1073737480 | US-OH-101556 | 2004-01-22 | Failure to comply with permit conditions | |
1435672041 | US-OH-112720 | 2015-12-15 | Well shall be plugged | |
1587793272 | US-OH-115530 | 2017-01-06 | 9-9-05(A)10 | Failure to legibly identify well |
For data sources see[8]