If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-115-63005 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.74,"lon":-81.98,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: York Township | |
Operator Name: TEMPLE OIL & GAS CO | |
Well Pad ID: | |
Farm/Lease Name: FYE GEORGE | |
License Status: Producing | |
License Date: 2008-07-31 | |
Spud Date: 1926-05-11 | |
Spud Drilling Contractor: | |
Final Drill Date: 1926-05-30 | |
Well Total Depth: 1364.00 ft | |
Configuration: Vertical | |
Latitude: 39.740000 | |
Longitude: -81.980000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Completed | 1926-01-01 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
Original Spud | 1926-05-11 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
Reached Total Depth | 1926-05-30 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
Oil and Gas | 2008-07-29 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
APP | 2008-07-31 | Proposed Formations:BEREA, Issued Date:7/31/2008, Expired Date:7/31/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Construction Permit Expires | 2009-07-31 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
Record Last Modified | 2013-10-03 | DAVE BALL INSPECTED THIS WELL ON 7/29/2008. THE WELL IS EQUIPPED WITH 7 INCH SURFACE CASING TO AN UNKNOWN DEPTH AND 2 INCH TUBING. RODS AND PUMPJACK HAD BEEN REMOVED FROM SITE. TEMPLE SAYS WELL DID NOT PRODUCE MUCH WHEN IT WAS OPERATING. |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 25 Qts | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TEMPLE OIL & GAS CO | 0.00 | 8.00 | 365 |
1986 | TEMPLE OIL & GAS CO | 0.00 | 119.00 | 365 |
1987 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 365 |
1990 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 365 |
1993 | TEMPLE OIL & GAS CO | 0.00 | 279.00 | 365 |
1995 | TEMPLE OIL & GAS CO | 0.00 | 188.00 | 365 |
1996 | TEMPLE OIL & GAS CO | 0.00 | 198.00 | 360 |
1997 | TEMPLE OIL & GAS CO | 0.00 | 238.00 | 250 |
1998 | TEMPLE OIL & GAS CO | 0.00 | 222.00 | 241 |
1999 | TEMPLE OIL & GAS CO | 1579.00 | 41.00 | 243 |
2000 | TEMPLE OIL & GAS CO | 0.00 | 157.00 | 261 |
2001 | TEMPLE OIL & GAS CO | 0.00 | 125.00 | 337 |
2002 | TEMPLE OIL & GAS CO | 0.00 | 144.00 | 257 |
2003 | TEMPLE OIL & GAS CO | 0.00 | 166.00 | 365 |
2004 | TEMPLE OIL & GAS CO | 0.00 | 208.00 | 253 |
2005 | TEMPLE OIL & GAS CO | 0.00 | 68.00 | 261 |
2006 | TEMPLE OIL & GAS CO | 0.00 | 45.00 | 313 |
2009 | TEMPLE OIL & GAS CO | 0.00 | 69.00 | 261 |
2011 | TEMPLE OIL & GAS CO | 2.00 | 161.00 | 365 |
2012 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 366 |
2013 | TEMPLE OIL & GAS CO | 0.00 | 66.00 | 365 |
2014 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 64 |
2015 | TEMPLE OIL & GAS CO | 0.00 | 157.00 | 64 |
2016 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 64 |
2017 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 365 |
2018 | TEMPLE OIL & GAS CO | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TEMPLE OIL & GAS CO | Brine | 68 | 365 |
1986 | TEMPLE OIL & GAS CO | Brine | 52 | 365 |
1987 | TEMPLE OIL & GAS CO | Brine | 224 | 365 |
1990 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
1993 | TEMPLE OIL & GAS CO | Brine | 1655 | 365 |
1995 | TEMPLE OIL & GAS CO | Brine | 1572 | 365 |
1996 | TEMPLE OIL & GAS CO | Brine | 1719 | 360 |
1997 | TEMPLE OIL & GAS CO | Brine | 0 | 250 |
1998 | TEMPLE OIL & GAS CO | Brine | 1610 | 241 |
1999 | TEMPLE OIL & GAS CO | Brine | 1378 | 243 |
2000 | TEMPLE OIL & GAS CO | Brine | 0 | 261 |
2001 | TEMPLE OIL & GAS CO | Brine | 1693 | 337 |
2002 | TEMPLE OIL & GAS CO | Brine | 2103 | 257 |
2003 | TEMPLE OIL & GAS CO | Brine | 1790 | 365 |
2004 | TEMPLE OIL & GAS CO | Brine | 1754 | 253 |
2005 | TEMPLE OIL & GAS CO | Brine | 1570 | 261 |
2006 | TEMPLE OIL & GAS CO | Brine | 1059 | 313 |
2009 | TEMPLE OIL & GAS CO | Brine | 0 | 261 |
2011 | TEMPLE OIL & GAS CO | Brine | 5 | 365 |
2012 | TEMPLE OIL & GAS CO | Brine | 0 | 366 |
2013 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2014 | TEMPLE OIL & GAS CO | Brine | 795 | 64 |
2015 | TEMPLE OIL & GAS CO | Brine | 2735 | 64 |
2016 | TEMPLE OIL & GAS CO | Brine | 0 | 64 |
2017 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
2018 | TEMPLE OIL & GAS CO | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1029952628 | 2015-10-6 0:00: | PW | No Violations | 1.50 |
-1177692002 | 2014-10-17 0:00 | PW | No Violations | |
-152480724 | 2014-1-10 0:00: | AM | No Violations | |
-1824709147 | 2014-1-8 0:00:0 | PW | No Violations | 1.00 |
-623895903 | 2016-5-12 0:00: | PW | No Violations | 1.00 |
-679622004 | 2014-1-14 0:00: | AM | No Violations | |
-86155131 | 2017-1-23 0:00: | AM | No Violations | 0.20 |
-92241417 | 2015-12-30 0:00 | PW | No Violations | 2.00 |
-9767723 | 2014-10-30 0:00 | PW | No Violations | |
0009767723 | 2014-10-30 | Production Wells | No Violations | The well was in operation when I arrived on location. The well is now in compliance. |
0086155131 | 2017-01-23 | Administrative Inspection | No Violations | I received an email from the Morgan County Inspector stating that the issues relating to the compliance notice I issued have been complied with. |
0092241417 | 2015-12-30 | Production Wells | No Violations | Follow up on NOV found that the leaking stuffing box had not been addressed and that more oily substances have accumulated around the casing head. |
0152480724 | 2014-01-10 | Administrative Inspection | No Violations | I returned a call to Tracey Swingle of Temple Oil and Gas and left a message in regards to a written plan/timeline for getting the idle wells plugged or back into production. |
0411160878 | 2015-12-02 | Production Wells | No Violations | Follow up found that nothing had been done to clean up the mess at the well head and it appeared as though the leak was still present. |
0623895903 | 2016-05-12 | Production Wells | No Violations | Upon my inspection today I found this well to be equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 2 inch diameter steel and plastic production lines, and 1 1/2 inch diameter production tubing. At the time of inspection there is still no identification on the well. The tank battery for this well is a shared tank battery and is equipped with two (2) 100 barrel steel tanks with proper identification for each well, a vertical separator, and a 50 barrel plastic tank. There has been no resolution to the identification issue with the well at this time. |
0679622004 | 2014-01-14 | Administrative Inspection | No Violations | I received a detailed letter from Tracey Swingle in regards to the three Fye wells asking for an extension of time on the compliance actions. Their plan at this time is to get all three wells back in production. |
0784483009 | 2007-09-10 | Production Wells | No Violations | Landowner wanted site inspected to make sure well was in compliance (Jeff Longhenry) no violations noted well is equipped with pump jack tubing&rods and 1-100 bbl tank owner still has old powerhouse on property and 2 old tanks told landowner once wells were plugged owner would be required to remove them from site. |
1029952628 | 2015-10-06 | Production Wells | Violations Noted | This unit was currently pumping when I arrived on location. The tank battery consisted on 2 steel 100 barrel tanks, one for brine the other for oil and a separator. The tank battery could easily be seen from the road and the well itself was down over the hill behind the tanks. I could hear fluid entering the tanks. I touched up the ID at the tanks. The stuffing box was leaking and will need to be tightened to stop the oil and brine from leaking around the polish rod and out onto the ground. Well will be corrected to prevent the release of oil and water from around the stuffing box. Production records shall be filed with the Columbus Office for the years 2013, and 2014 |
1083436735 | 2017-01-04 | Production Wells | No Violations | The inspection today revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 2 inch steel production lines, and 1 1/2 inch diameter production tubing. The valves are currently open at the time of inspection. Inspector Matt Fulk wrote this well up for contamination and failure to prevent the escape of gas or oil. The inspection today revealed that the contamination has been cleaned up and there are no leaks at the time of inspection. The well is now in compliance. The tank battery is at the top of the hill and consists of two (2) 100 barrel steel tanks with proper identification. There are no issues to report at the time of inspection and, the well is in compliance at the time of inspection. |
1177692002 | 2014-10-17 | Production Wells | No Violations | Comliance Notice Follow-up -1824709147: The service rig and frac tanks were on location. The operator has cemented the 4.5 casing. I talked to Tracey from Temple and he stated they have the completions set up for Monday. |
1217371169 | 2008-07-29 | Plug / Plug Back | No Violations | Request from Central Office to look at well for possible plugging permit being issued ,well is now equipped with 7 surface casing and 2 tubing&rods pump jack has been removed from site since my last inspection,owner stated well tender thought water had broke in on formation(Berea well) total depth should be in the 1300 range. |
1414508412 | 2014-10-28 | Production Wells | No Violations | Comliance Notice Follow-up -1824709147: Operator was on location hooking up the pumping unit to the wellhead. A new dike with two 100 bbl tanks was constructed at the top of the access road. Tracey Swingle stated that the well will be in production by the end of the week. |
1824709147 | 2014-01-08 | Production Wells | Violations Noted | Well is sitting idle and is equipped with 4.5 casing, tubing, and rods. The pumpjack has been removed from wellhead and there is a 2 black plastic line that is cut off at the top of the hill. There are no tanks found for this well. Operator must plug or produce well within 90 days. |
411160878 | 2015-12-2 0:00: | PW | No Violations | 1.50 |
784483009 | 2007-9-10 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1029952628 | US-OH-100129 | 2015-10-19 | Well operation causing pollution and contamination | |
1029952628 | US-OH-100130 | 2015-10-19 | Well insufficiently equipped to prevent escape of oil and gas | |
1029952628 | US-OH-100131 | 2015-10-19 | Statement of annual production not filed | |
1824709147 | US-OH-118157 | 2014-11-03 | Well shall be plugged | |
1824709147 | US-OH-118158 | 2014-11-03 | Nonproduction; well shall be plugged or placed in temporary inactive status |
For data sources see[8]