If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-117-23012 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.48,"lon":-82.86,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Morrow | |
| Municipality: Lincoln Township | |
| Operator Name: FISHBURN PRODUCING INC | |
| Well Pad ID: | |
| Farm/Lease Name: FRAKER & HEIMLICH | |
| License Status: Producing | |
| License Date: 1967-08-10 | |
| Spud Date: 1967-08-07 | |
| Spud Drilling Contractor: | |
| Final Drill Date: 1967-09-06 | |
| Well Total Depth: 3135.00 ft | |
| Configuration: Vertical | |
| Latitude: 40.480000 | |
| Longitude: -82.860000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| Original Spud | 1967-08-07 | GL=1049.65, DF=1051.65 |
| Completed | 1967-09-06 | GL=1049.65, DF=1051.65 |
| Reached Total Depth | 1967-09-06 | GL=1049.65, DF=1051.65 |
| CO | 1995-05-30 | 4958 HATCO PRODUCTION INC GeoDate |
| CO | 1995-05-30 | 513 DALTON & HANNA CO |
| Change of Owner | 2015-06-19 | Operator changed from 4958, HATCO PRODUCTION INC to 4260, CORTLAND ENERGY CO INC |
| Change of Owner | 2015-07-23 | Operator changed from 4260, CORTLAND ENERGY CO INC to 3941, FISHBURN PRODUCING INC |
| Record Last Modified | 2015-07-23 | GL=1049.65, DF=1051.65 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2006-09-11 | 3103 | 3135 | 0 |
| 3103 | 3135 | 0 | |
| 3103 | 3135 | 0 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| ACID | 0 | 2000 Gal | 0 |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1984 | DALTON & HANNA LTD | 0.00 | 455.00 | 0 |
| 1985 | DALTON & HANNA LTD | 0.00 | 278.00 | 365 |
| 1986 | DALTON & HANNA LTD | 0.00 | 71.00 | 365 |
| 1987 | DALTON & HANNA LTD | 0.00 | 150.00 | 365 |
| 1988 | DALTON & HANNA LTD | 0.00 | 448.00 | 365 |
| 1989 | DALTON & HANNA LTD | 0.00 | 502.00 | 365 |
| 1990 | DALTON & HANNA LTD | 0.00 | 70.00 | 365 |
| 1991 | DALTON & HANNA LTD | 0.00 | 438.00 | 365 |
| 1992 | DALTON & HANNA LTD | 0.00 | 152.00 | 365 |
| 1993 | HATCO PRODUCTION INC | 0.00 | 530.00 | 200 |
| 1994 | HATCO PRODUCTION INC | 0.00 | 351.00 | 300 |
| 1997 | HATCO PRODUCTION INC | 0.00 | 122.00 | 110 |
| 1998 | HATCO PRODUCTION INC | 0.00 | 155.00 | 100 |
| 1999 | HATCO PRODUCTION INC | 0.00 | 240.00 | 48 |
| 2000 | HATCO PRODUCTION INC | 0.00 | 155.00 | 300 |
| 2001 | HATCO PRODUCTION INC | 0.00 | 308.00 | 120 |
| 2002 | HATCO PRODUCTION INC | 0.00 | 247.00 | 96 |
| 2003 | HATCO PRODUCTION INC | 0.00 | 232.00 | 100 |
| 2004 | HATCO PRODUCTION INC | 0.00 | 245.00 | 190 |
| 2005 | HATCO PRODUCTION INC | 0.00 | 244.00 | 299 |
| 2006 | HATCO PRODUCTION INC | 0.00 | 234.00 | 190 |
| 2007 | HATCO PRODUCTION INC | 0.00 | 230.00 | 190 |
| 2008 | CORTLAND ENERGY CO INC | 0.00 | 102.00 | 20 |
| 2009 | CORTLAND ENERGY CO INC | 0.00 | 88.00 | 38 |
| 2010 | CORTLAND ENERGY CO INC | 0.00 | 78.00 | 365 |
| 2011 | CORTLAND ENERGY CO INC | 0.00 | 109.00 | 365 |
| 2012 | CORTLAND ENERGY CO INC | 0.00 | 134.00 | 366 |
| 2013 | CORTLAND ENERGY CO INC | 0.00 | 81.00 | 0 |
| 2014 | HATCO PRODUCTION INC | 0.00 | 0.00 | 0 |
| 2015 | FISHBURN PRODUCING INC | 0.00 | 0.00 | 73 |
| 2016 | FISHBURN PRODUCING INC | 0.00 | 60.00 | 50 |
| 2017 | FISHBURN PRODUCING INC | 0.00 | 0.00 | 56 |
| 2018 | FISHBURN PRODUCING INC | 0.00 | 169.00 | 131 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1094087482 | 2019-11-19 0:00 | PW | No Violations | 0.40 |
| -1326103250 | 2020-4-22 0:00: | PW | No Violations | |
| -138767195 | 2016-8-26 0:00: | PW | No Violations | |
| -1393827410 | 2019-3-26 0:00: | PW | No Violations | |
| -1423341094 | 2015-6-24 0:00: | PW | No Violations | |
| -1542168051 | 2020-1-16 0:00: | PW | No Violations | 0.50 |
| -1606970578 | 2016-8-29 0:00: | PW | No Violations | |
| -1775294085 | 2016-8-30 0:00: | PW | No Violations | |
| -2010134122 | 2019-9-23 0:00: | PW | No Violations | |
| -547062538 | 2020-9-25 0:00: | PW | No Violations | |
| -895116376 | 2017-12-18 0:00 | PW | No Violations | |
| 0138767195 | 2016-08-26 | Production Wells | No Violations | On-site with Emergency Operations coordinator Vikki Bunting for remediation. Fishburn has begun hauling contaminated soil off location. Excavation reveal the flowline failed at a butt weld. Retention ditches were dug to mitigate flow over the weekend. |
| 0824585241 | 2014-09-22 | Production Wells | No Violations | Location Information for the Fraker-Heimlich Unit #1 (#3012). WELL HEAD: Lat. 40.48350 Long. -82.86147 / CENTER-OF-STORAGE: Lat. 40.48549 Long. -82.86028 / ENTRANCE: Lat. 40.48759 Long. -82.85855. |
| 0864118772 | 2014-05-29 | Production Wells | No Violations | The siphon ditch has been closed in. Residual oil remains and has soaked through the peat and straw. Additional remediation needed. Status: contacted operator. |
| 0895116376 | 2017-12-18 | Production Wells | No Violations | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. The well was not pumping at the time of inspection. |
| 0944555545 | 2013-09-06 | Production Wells | No Violations | Inspected the Fraker-Heimlich Unit #1 (#3012) as part of a standard production well status check. Check well, storage and identification. The well identification and emergency contact information has been posted on the tanks. Status: corrective notice for well identification cleared, ok. |
| 0949237350 | 2014-09-22 | Production Wells | No Violations | Inspected the Fraker-Heimlich Unit #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. |
| 0993951746 | 2014-04-10 | Production Wells | No Violations | The operator has covered the affected area with biological material and straw. Status: the operator plans to close in the siphon dam. |
| 0994716428 | 2016-08-24 | Production Wells | Violations Noted | Routine inspection revealed a flowline failure had occurred. Approximate loss of 4 to 6 barrels of fluid pooled at the breach and moved down the gravel lease road. The operator shut-in the well and has temporarily spread thick saw dust on the lease road to mitigate further migration. Status: release contained, contacted operator to discuss remediation. |
| 1003159693 | 2017-09-19 | Production Wells | No Violations | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. |
| 1108226035 | 2020-8-25 0:00: | PW | No Violations | |
| 1358360829 | 2013-01-15 | Production Wells | Violations Noted | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard productive well status check. The well is equipped with a black Alten gas/electric powered pump jack and the well pad is free of excess contamination. The storage consists of two silver storage set on a gravel pad, the separator has been removed but the pads remain south of the tanks. No well identification or emergency contact information is posted at the well or storage. Current ownership is noted as Hatco Production, while the well tender stated it is owned by Cortland energy. Have made in inquiry to Erica Freeman and they are going to change ownership as per email from Patty Nicklaus. Called Gary VanDyke (1/18/13) and alerted him to the missing well identification. |
| 1393827410 | 2019-03-26 | Production Wells | No Violations | Visit location with NW Regional Supervisor Mr. Stephen Ochs. |
| 1396291850 | 2014-03-31 | Production Wells | Violations Noted | The landowner brush hogged around the production equipment and accidently broke off a quarter inch nipple at a check valve on the flow line near the separator pad (unnoticed by the landowner). Estimated 3 to 4 barrels of oil pooled on the ground and ran down slope approximately 100 feet. No streams were impacted and the oil stayed at the surface due to the soil being saturated after recent heavy rains. Remediation: dug a retention ditch with siphon dam and flushed with fresh water. Will continue to monitor. |
| 1396466277 | 2014-04-02 | Production Wells | No Violations | Heavy overnight rains have flushed the site aiding remediation. The operator has added biological material to the effected soil. Kenny Smith (welder) is on site to begin repairing the flow line. Status: will continue to monitor. |
| 1396962667 | 2014-04-08 | Production Wells | No Violations | The operator has repaired the flow line at the break and recent heavy rains have flushed the impacted area nicely. Status: will continue to monitor remediation. |
| 1416576680 | 2014-11-21 | Production Wells | No Violations | The impacted area from the flow line breach has been remediated. This clears the corrective action written 3/31/2014 for pollution and contamination. |
| 1423341094 | 2015-06-24 | Production Wells | No Violations | Fishburn has posted the well identification and emergency contact information. Status: as per Fishburn, Cortland Energy is in the process of correcting the ownership issues with the Division. Will continue to monitor. |
| 1438089348 | 2015-07-28 | Administrative Inspection | No Violations | Change-of-operator noted from Cortland Energy to Fishburn Producing: effective date 7/23/2015. |
| 1468000882 | 2018-09-17 | Production Wells | No Violations | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. The well was pumping at the time of inspection. |
| 1473257256 | 2016-08-25 | Production Wells | No Violations | The operator has begun moving equipment to location for soil removal. They also hauled in extra saw dust for the lease road. |
| 1475245493 | 2016-09-29 | Production Wells | No Violations | Check status of remediation. Status: ok. |
| 1553694926 | 2019-03-27 | Production Wells | Violations Noted | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: the well identification sign is missing. Contacted the operator by email for remedy request. |
| 1554471047 | 2019-04-05 | Production Wells | No Violations | The operator has replaced the identification at the storage. Status: ok. The well was pumping at the time of inspection. |
| 1605218102 | 2019-6-13 0:00: | PW | No Violations | |
| 1606970578 | 2016-08-29 | Production Wells | No Violations | The operator has flushed the entire flowline and has begun cutting into sections for disposal. Continued soil and tree removal in progress. |
| 1695461678 | 2020-5-26 0:00: | PW | No Violations | |
| 1775294085 | 2016-08-30 | Production Wells | No Violations | The topsoil has been replaced and finished graded. This completes the remediation and clears the previous violation. |
| 183709420 | 2020-5-4 0:00:0 | PW | No Violations | |
| 1913701686 | 2006-05-19 | Production Wells | No Violations | Chk well and storage, Ok. |
| 1991622375 | 2018-10-15 | Production Wells | No Violations | Inspected the Fraker-Heimlich #1 (#3012) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. The well was pumping at the time of inspection. |
| 824585241 | 2014-9-22 0:00: | PW | No Violations | |
| 864118772 | 2014-5-29 0:00: | PW | No Violations | |
| 944555545 | 2013-9-6 0:00:0 | PW | No Violations | |
| 949237350 | 2014-9-22 0:00: | PW | No Violations | |
| 993951746 | 2014-4-10 0:00: | PW | No Violations | |
| 994716428 | 2016-8-24 0:00: | PW | No Violations |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0994716428 | US-OH-131413 | 2016-09-19 | Well operation causing pollution and contamination | |
| 1358360829 | US-OH-110397 | 2014-04-23 | Failure to legibly identify well | |
| 1396291850 | US-OH-111723 | 2014-11-24 | Well operation causing pollution and contamination | |
| 1553694926 | US-OH-115103 | 2019-04-01 | 9-9-05(A)10 | Failure to legibly identify well |
For data sources see[9]