Well Details

Well ID: 34-119-24439
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Meigs Township
Operator Name: J M ADAMS ROUSTABOUT PIPE
Well Pad ID:
Farm/Lease Name: ROGERS & ROSEN (SWIW #17)
License Status: Active Injection
License Date: 1994-07-29
Spud Date: 1978-10-22
Spud Drilling Contractor:
Final Drill Date: 1978-10-25
Well Total Depth: 1575.00 ft
Configuration: Vertical
Latitude: 39.770000
Longitude: -81.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1978-10-13 312 B B ENERGY CORP GeoDate 10/13/78
Original Spud 1978-10-22 CONVERT 12-21-85
Completed 1978-10-25 CONVERT 12-21-85
Reached Total Depth 1978-10-25 CONVERT 12-21-85
CO 1985-12-20 312 B B ENERGY CORP GeoDate 12/20/85
Salt Water Injection Well 1985-12-20 Issued Date 12/20/85 Expired Date 12/20/86 Acres 0010000 Tool Type CT Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1985-12-20 Issued Date 12/20/85 Expired Date 12/20/86 Acres 0010000 Tool Type CT Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Annulus Pressure Monitoring Approved 1986-01-16 CONVERT 12-21-85
CO 1994-05-23 171 LYDIC W J INC GeoDate 12/20/85
CO 1994-07-29 171 LYDIC W J INC GeoDate 7/29/94
Unknown 1994-07-29 Issued Date 7/29/94 Expired Date 7/29/95 Proposed Purpose SW Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1995-02-28 5053 STALLION PETROLEUM INC GeoDate 7/29/94
Construction Permit Expires 1995-07-29 CONVERT 12-21-85
CO 1996-10-16 3388 ADAMS JM ROUSTABOUT/PIPE GeoDate 7/29/94
Last Compliance Report 2011-06-24 CONVERT 12-21-85
Record Last Modified 2013-04-24 CONVERT 12-21-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1488 1494 12
1488 1494 12
1488 1494 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 B B ENERGY CORP 0.00 142.00 0
1986 B B ENERGY CORP 0.00 0.00 0
1987 B B ENERGY CORP 0.00 0.00 0
1988 B B ENERGY CORP 0.00 0.00 365
1998 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
1999 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2000 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 25
2001 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2002 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2003 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2004 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2005 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2007 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2008 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2009 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2010 J M ADAMS ROUSTABOUT PIPE 0.00 0.00 0
2011 J M ADAMS ROUSTABOUT PIPE 0.00 26.00 61
2012 J M ADAMS ROUSTABOUT PIPE 0.00 43.00 0
2014 J M ADAMS ROUSTABOUT PIPE 0.00 219.00 365
2015 J M ADAMS ROUSTABOUT PIPE 0.00 311.00 365
2017 J M ADAMS ROUSTABOUT PIPE 0.00 154.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 B B ENERGY CORP Brine 510 0
1986 B B ENERGY CORP Brine 0 0
1987 B B ENERGY CORP Brine 0 0
1988 B B ENERGY CORP Brine 0 365
1998 J M ADAMS ROUSTABOUT PIPE Brine 0 0
1999 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2000 J M ADAMS ROUSTABOUT PIPE Brine 0 25
2001 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2002 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2003 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2004 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2005 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2007 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2008 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2009 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2010 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2011 J M ADAMS ROUSTABOUT PIPE Brine 0 61
2012 J M ADAMS ROUSTABOUT PIPE Brine 0 0
2014 J M ADAMS ROUSTABOUT PIPE Brine 0 365
2015 J M ADAMS ROUSTABOUT PIPE Brine 0 365
2017 J M ADAMS ROUSTABOUT PIPE Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1058107363 2012-10-10 0:00 SW No Violations
-132140294 2011-12-29 0:00 SW No Violations 1.00
-1491087576 2018-1-18 0:00: SW No Violations
-1507755867 2018-7-3 0:00:0 SW No Violations
-1575989565 2019-9-3 0:00:0 SW No Violations
-1776785511 2016-1-13 0:00: SW No Violations
-1830867540 2013-12-12 0:00 SW No Violations
-1864179793 2012-3-22 0:00: SW No Violations 1.50
-1871070848 2016-5-5 0:00:0 SW No Violations
-1948925438 2018-5-21 0:00: SW No Violations
-2092381962 2013-4-3 0:00:0 SW No Violations 1.00
-2114204537 2016-9-8 0:00:0 SW No Violations
-24520144 2017-10-20 0:00 SW No Violations
-315356772 2014-11-5 0:00: SW No Violations
-319232259 2012-12-5 0:00: SW No Violations
-369072198 2012-1-25 0:00: SW No Violations 1.50
-405204589 2018-12-12 0:00 SW No Violations
-536715201 2012-5-17 0:00: SW No Violations 1.50
-582380800 2014-7-21 0:00: SW No Violations
-616005497 2015-5-13 0:00: SW No Violations
-689855329 2014-1-29 0:00: SW No Violations
-770695331 2020-6-11 0:00: SW No Violations
-825196087 2013-9-18 0:00: SW No Violations
-864916443 2018-3-28 0:00: SW No Violations
000UIC1112 1991-06-21 Salt Water Injection Well No Violations 1501:9-3-07 (E) & (F) 1ST.QTR. 1991 RPT.
0024520144 2017-10-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and I call company and requested that they have fresh water removed from dike area to allow for volume in the event of tank failure.
0029663923 2011-12-05 Salt Water Injection Well No Violations JM Adams and I met and tested the annulas at 420psi.The flow line was also tested at 420 psi.All tests passed.
0061588669 2016-02-03 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0132140294 2011-12-29 Salt Water Injection Well No Violations On day of inspection no violations noted.Facility is in compliance.
0250335445 2015-09-03 Salt Water Injection Well Violations Noted Stopped by site to check up on clean up efforts being made at site, owner has gathered up all contaminated material and placed it on plastic liner waiting for roll off box to be delivered so they can ship material to a approved site for disposal.

Note: Owner is trying to locate service rig to repair well.

Violations at the site has been resolved.

0304698745 2019-02-15 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and it was noted that fresh water has built up in containment area and I called company rep and requested that they remove fresh water in dike to allow for volume in the event of spill.
0315356772 2014-11-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and one Enervest Operating vacuum truck was unloading at the facility during my inspection.
0319232259 2012-12-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that exposed portion of pit liner still needs to be covered with stone to help prevent rotting due to exposure to sunlight.
0342274625 2014-05-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that company owned vacuum truck was parked on unloading on the day of my inspection.
0369072198 2012-01-25 Salt Water Injection Well No Violations On day of inspection there were no violations noted.Well was not pumping.
0405204589 2018-12-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Unable to record pressures due to extreme cold valves were froze up.

0536715201 2012-05-17 Salt Water Injection Well No Violations On day of inspection no violation noted.Dave Ball made suggestion of gravel on pit liner because of break down.
0582380800 2014-07-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0616005497 2015-05-13 Salt Water Injection Well No Violations Inspection revealed that injection pump not in operation during my inspection and it was noted that company owned vacuum truck was parked at the facility .
0689855329 2014-01-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Enervest Operating vacuum truck was unloading at facility during my inspection.
0808376734 2018-04-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and well is not being used much at this time.

Note: Walked flowline area today.

0825196087 2013-09-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Walked flow line area to monitor area for leakage none were noted on this day.

0864916443 2018-03-28 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
0901207658 2012-05-17 Salt Water Injection Well No Violations Inspection on this day revealed that injection pump was in operation when I arrived on site but by the time I walked to wellhead it had shut off and it was noted that pit liner in tank area needs to be covered with stone to help prevent damage to liner due to exposure to the sunlight.
0941525119 2019-04-07 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.

Note: Walked flowline area to wellhead and noticed that there was several trees across lease road called company and requested that they have trees removed from road area too allow access to wellhead.

1058107363 2012-10-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Exposed portion of liner in tank area needs to be covered with material so sunlight does not rot it out and open trash pit next to tank area needs to be filled in and trash hauled to a landfill.

1067973196 2015-11-12 Salt Water Injection Well No Violations Well is currently injecting saltwater and has just been put back into working order under the supervision of the UIC inspector. The well is equipped with 4.5casing on clamp, 4.5x 2.875 tubing head and a 2.875x 1.5tubing head. There are 1-140, 1-400, 1-250 barrel steel tanks for salt water storage and 1-100 barrel and a 30 barrel poly tank for oil storage. The pump house is in good working order. The identifications are at the well and the pump house. The well coordinates are 39.77082,-81.81592 epe24. The tank coordinates are 39.77460,-81.81807 epe19. The entry coordinates are 39.77479,-81.81819 epe19.
1076404038 2015-10-09 Salt Water Injection Well No Violations On day of inspection Buckston rig over well pulling 1401 of 2.375 upset 8 round tubing out. At the bottom there was a left threaded collar. Rig stated that 1 turn backed off the tubing. The collar has areas of wash-outs. The rig was gave options on getting the packer out. The rig was gave the option to drive or swivel the packer to the bottom of the well. The top perf is at 1438 and the bottom perf is at 1494. There is a Halliburton R-4 packer at 1411.
1270087787 2013-07-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection .

Note: Walked flowline area to monitor for possible leaks,none were found on this day.

1304882631 2015-02-04 Salt Water Injection Well No Violations Inspection revealed that owner had recently started injection pump and in conversation with him stating that secondary roads were ice covered and they were not receiving much water at this time.
1330657832 2012-02-22 Salt Water Injection Well No Violations On day of inspection well was not being pumped into. Well and Facility in good working order.
1384806256 2013-11-18 Salt Water Injection Well No Violations Inspection revealed that owner has covered exposed portions of liner as requested by inspector and it was noted that company owned water truck was unloading at facility during my inspection.
1441234543 2015-09-02 Salt Water Injection Well Violations Noted Inspection revealed that production casing possibly has hole in it and brine/oil has made it way onto the ground and affected area needs to be cleaned up and any contaminated soils need to be removed from site and disposed of properly.

Plan for reworking well needs to be submitted to the UIC section ASAP for there approval of reworking well and any remedial work at the site that is needed. Several photos of site have been taken.

1444949222 2015-10-13 Salt Water Injection Well No Violations On site to witness operator run 1402 of 2.875 in hole and cement it in place with 40 sacks of Class A cement and estimated top of cement should be approximately 300 will confirm with bond log in the morning.
1445035491 2015-10-14 Salt Water Injection Well No Violations On site to bond log 2.875 to confirm cement top on backside of casing it was at 476 and then Timco Services rigged up power swivel and drilled cement out within casing and cleaned out hole to 1520 and then we ran Parmaco packer on 1.5 tubing to 1387 and Formation Cementing pumped fresh water and inhibitor in well to prepare casing for required MIT test, we tested at 580 psi with no decline in pressure.

Note: Packer set in tension 12 K.

1448194096 2015-11-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that company owned vacuum truck was hauling brine into the facility during my inspection.
1456054903 2016-02-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that company owned vacuum truck 25-373 was parked at the facility on this day of my inspection.
1465846891 2016-06-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that company owned vacuum truck was parked within the fenced in area at the unloading pad area.
1470228726 2016-08-02 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation.


Note: Walked flow line area to monitor for any potential leaks none were noted.

1488528935 2017-01-23 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.

Note: Walked flowline area to wellhead to monitor area for any potential problems none were found today.

1491087576 2018-01-18 Salt Water Injection Well No Violations Inspection revealed that well is not in service at this time due to extreme cold weather.

Note: Walked flowline area today.

1493035557 2017-04-23 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it was noted that a tree has fallen across lease road to wellhead and I called company rep Josh Adams and requested that they remove tree to allow access to wellhead.
1497128635 2017-06-09 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and it was noted that company owned vacuum truck was locked up within the unloading pad area.
1501422763 2017-07-27 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
1507755867 2018-07-03 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.
1550160472 2016-03-16 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted that owners vacuum truck was parked at the facility in behind the security fence.
1623066692 2009-04-09 Salt Water Injection Well No Violations Pressured up on backside and well passed MIT. Well was supposed to have been plugged years ago by previous owner. Current owener wants to put the well back in use. Will do an injection test to see if well can take fluid at < the maximum injection pressure. No tank battery.
1760483633 2011-11-18 Surface Facility Construction No Violations In process of building facility. They are preparing to pour dike walls for unloading pad. A liner was placed on the dike walls around tanks. The tanks were set and painted. The chain link fence is also in place. The pump house is built.
1776785511 2016-01-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that all previous violations at the site has been resolved.
1830867540 2013-12-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection.
1864179793 2012-03-22 Salt Water Injection Well No Violations On day of inspection well is not pumping. There are no violations present.
1871070848 2016-05-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1948925438 2018-05-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
2004360081 2016-11-09 Salt Water Injection Well No Violations Injection pump was not in operation during my inspection.

Note: Company owned vacuum truck was parked within fenced in area at the site today.

2006771008 2013-09-27 Salt Water Injection Well No Violations On site to witness owner apply positive pressure to annulus of tubing , on my last inspection pressure was at zero so I contacted Josh Adams and requested that he apply pressure to annulus of tubing to ensure that they had good casing integrity.
2092381962 2013-04-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at facility during my inspection.

Note: Walked flow line area to check for possible leaks none were found today.

2114204537 2016-09-08 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation and it was noted that workers have recently removed brush from the outside of fenced tank storage area.
250335445 2015-9-3 0:00:0 SW No Violations
29663923 2011-12-5 0:00: SW No Violations 2.00
304698745 2019-2-15 0:00: SW No Violations
342274625 2014-5-14 0:00: SW No Violations
397732526 2019-6-25 0:00: SW No Violations
61588669 2016-2-3 0:00:0 SW No Violations
808376734 2018-4-17 0:00: SW No Violations
901207658 2012-5-17 0:00: SW No Violations
941525119 2019-4-7 0:00:0 SW No Violations
UIC1112 1991-6-21 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0250335445 US-OH-122573 2016-01-21 Mechanical failure/contamination
1441234543 US-OH-112838 2015-10-07 Mechanical failure/contamination

For data sources see[9]

References