X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-119-27534

Well Details

Well ID: 34-119-27534
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Brush Creek Township
Operator Name: S & S OIL CO
Well Pad ID:
Farm/Lease Name: S & S OIL CO
License Status: Final Restoration
License Date: 2018-06-08
Spud Date: 1988-07-25
Spud Drilling Contractor: UNGER DRILLING
Final Drill Date: 1988-07-30
Well Total Depth: 3956.00 ft
Configuration: Vertical
Latitude: 39.870000
Longitude: -81.950000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-06-29 Issued Date 6/29/88 Expired Date 6/29/89 Acres 0040000 Tool Type RTAF Proposed Formation MEDINA Proposed Depth 03956 Proposed Drill Depth 03956
Original Spud 1988-07-25 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Completed 1988-07-30 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Reached Total Depth 1988-07-30 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
CO 1988-09-30 288 S & S OIL CO GeoDate 6/29/88
Completion Report Received 1991-01-09 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Last Compliance Report 2012-10-15 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
APP 2018-06-08 Proposed Formations:CLINTON, Issued Date:6/8/2018, Expired Date:6/7/2020 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-10-04 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Record Last Modified 2019-05-18 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.
Construction Permit Expires 2020-06-07 UPDATE LOCATION PER DOGRM SURVEYOR COORDINATES.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3782 3802 21
3733 3807 0
1997-06-29 3733 3807 0
3782 3802 21
3733 3807 0
2006-09-11 3806 3807 2
2006-09-11 3875 3879 4
2006-09-11 3869 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 S & S OIL CO 0.00 0.00 365
1991 S & S OIL CO 0.00 0.00 365
2007 S & S OIL CO 0.00 0.00 365
2008 S & S OIL CO 0.00 0.00 365
2013 S & S OIL CO 0.00 0.00 0
2014 S & S OIL CO 0.00 0.00 0
2015 S & S OIL CO 0.00 0.00 0
2016 S & S OIL CO 0.00 0.00 0
2017 S & S OIL CO 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 S & S OIL CO Brine 0 365
1991 S & S OIL CO Brine 0 365
2007 S & S OIL CO Brine 0 365
2008 S & S OIL CO Brine 0 365
2013 S & S OIL CO Brine 0 0
2014 S & S OIL CO Brine 0 0
2015 S & S OIL CO Brine 0 0
2016 S & S OIL CO Brine 0 0
2017 S & S OIL CO Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1256615218 2019-4-10 0:00: FR No Violations 0.20
-1593496543 2006-11-15 0:00 AD No Violations
-1940938330 2018-3-23 0:00: PW No Violations 0.50
-45533116 2018-2-23 0:00: TD No Violations 0.50
-742819057 2004-2-11 0:00: AD No Violations
0000PL7901 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0045533116 2018-02-23 Temporary Abandoned Annular Disposal No Violations The day of my inspection the Annular Disposal is not hooked up.
0539442417 2018-09-28 Plug / Plug Back No Violations The inspection is conducted under plugging operation and Compliance Notice Follow-up to number -1940938330. Chipco rig 7 is over the well and had pulled all the rods and pump out of the well. The tubing was at 3800 feet. The Clinton plug was placed from 3800- 3400 feet in the 4 1/2inch casing with 2 3/8- inch tubing. Chipco ran 30 sacks of regular class A cement at 15.6 lb. /gallon and a 1.18 yield. The displacement was 13 barrels of fresh water. The rig started pulling all 2 3/8-inch tubing from the well.
0742819057 2004-02-11 Annular Disposal No Violations AD not in use. Well used for gas for the plant.
0750042302 2018-10-01 Plug / Plug Back No Violations The inspection is conducted under plugging operations and Compliance Follow-up to number --
1102174563 2019-02-22 Final Restoration No Violations On the day of my inspection the Final Restoration passed. The location meets the 1509.072. There is good vegetation established to prevent substantial erosion.
1331221091 2012-03-08 Annular Disposal No Violations Inspection found AD not in use or hooked up, well equipped with 4.5 casing 2.375 tubing and a pumping unit ,Inspector will note 100 barrel tank for well is located behind shop besides other well on property with the permit # 3411926717, Also spoke with company representative about proper dicing, labeling -etc, He also stated well is being produced for gas only ay present time.
1593496543 2006-11-15 Annular Disposal No Violations No AD.
1701579744 2018-10-04 Plug / Plug Back No Violations The inspection is conducted under plugging operations and a follow up to Compliance Notice number --1900 feet. Chipco Cementing set a 60 sack plug of regular class A cement at 15.6 lb. /gallon. The displacement was with 4.7 barrels of fresh water. The Berea plug was set from 1095-889 feet. Chipco Cementing set a 60 sack plug of regular class A cement at 15.6 lb. /gallon. The displacement was with 2.2 barrels of fresh water. The Bottom of surface plug was set from 654-454 feet. Chipco Cementing set a 60 sack plug of regular class A cement at 15.6 lb. /gallon. The displacement was with 1.1 barrels of fresh water. The surface plug was set from 200-0. Chipco Cementing set a 60 sack plug of regular class A cement at 15.6 lb. /gallon. The plug was being pumped to circulate the cement slurry to surface. The weight of the cement broke thru a coal seam. The circulation stopped and Chipco shut down for 1 hour. They finished breaking the well head down. Chipco set a stone and brush plug and set cement plug of 35 sacks of regular class A cement at 15.6 lbs./ gallon. The cement dropped back about 12 feet. They would sack-Crete the well back after cutting the 8 5/8 inch well head and cut the casing down 30 inches below grade. The plug job has been completed on this date of 10-4-18 resolving the Compliance Notice.
1940938330 2018-03-23 Production Wells Violations Noted
539442417 2018-9-28 0:00: PB No Violations 1.20
750042302 2018-10-1 0:00: PB No Violations 5.20
PL7901 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1940938330 US-OH-119541 2018-04-11 Failure to have required locks, bull plugs
1940938330 US-OH-119542 2018-04-11 Well shall be plugged

For data sources see[9]

References