Well ID: 34-119-28749
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Meigs Township
Operator Name: ANADARKO E & P ONSHORE LLC
Well Pad ID: US-OH-000488
Farm/Lease Name: FREC MEIGS
License Status: Plugged Back
License Date: 2012-03-23
Spud Date: 2012-03-27
Spud Drilling Contractor: KEY ENERGY
Final Drill Date: 2012-04-08
Well Total Depth:
Configuration: Vertical
Latitude: 39.820000
Longitude: -81.750000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-12-29 Proposed Formations:TRENTON/BLACKRIVER, Issued Date:12/29/2011, Expired Date:12/28/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2012-03-23 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:3/23/2012, Expired Date:3/23/2014 12:00:00 PM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:
Plugged Back 2012-04-07 UPDATED SLANT FROM DIRECTIONAL TO VERTICAL, THIS WAS A STRAT WELL, ORIGINALLY HAD DIRECTIONAL WITH A TARGET HOLE, SEE 34-119-28749-01 FOR LATERAL COORDINATES-ALE 12/21/17.
Reached Total Depth 2012-04-08 UPDATED SLANT FROM DIRECTIONAL TO VERTICAL, THIS WAS A STRAT WELL, ORIGINALLY HAD DIRECTIONAL WITH A TARGET HOLE, SEE 34-119-28749-01 FOR LATERAL COORDINATES-ALE 12/21/17.
Correction to Well 2012-05-18 CORRECTION TO WELL NUMBER.
Completion Report Received 2012-10-01 UPDATED SLANT FROM DIRECTIONAL TO VERTICAL, THIS WAS A STRAT WELL, ORIGINALLY HAD DIRECTIONAL WITH A TARGET HOLE, SEE 34-119-28749-01 FOR LATERAL COORDINATES-ALE 12/21/17.
Construction Permit Expires 2014-03-23 UPDATED SLANT FROM DIRECTIONAL TO VERTICAL, THIS WAS A STRAT WELL, ORIGINALLY HAD DIRECTIONAL WITH A TARGET HOLE, SEE 34-119-28749-01 FOR LATERAL COORDINATES-ALE 12/21/17.
Record Last Modified 2017-12-21 UPDATED SLANT FROM DIRECTIONAL TO VERTICAL, THIS WAS A STRAT WELL, ORIGINALLY HAD DIRECTIONAL WITH A TARGET HOLE, SEE 34-119-28749-01 FOR LATERAL COORDINATES-ALE 12/21/17.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-10-24 9727 9510 40
2012-10-24 11887 11670 40
2012-10-24 11647 11430 40
2012-10-24 12369 12157 40
2012-10-24 12064 11920 40
2012-10-24 11407 11190 40
2012-10-24 10687 10470 40
2012-10-24 10447 10230 40
2012-10-24 11167 10950 40
2012-10-24 10927 10710 40
2012-10-24 9487 9270 40
8287 8070 40
12064 11920 40
11887 11670 40
11647 11430 40
11407 11190 40
11167 10950 40
10927 10710 40
10687 10470 40
10447 10230 40
10207 9990 40
9967 9750 40
9727 9510 40
9487 9270 40
9247 9030 40
9007 8790 40
8767 8550 40
8527 8310 40
12369 12157 40
8287 8070 40
2012-10-24 10207 9990 40
2012-10-24 9967 9750 40
2012-10-24 9247 9030 40
2012-10-24 8527 8310 40
2012-10-24 8287 8070 40
2012-10-24 9007 8790 40
2012-10-24 8767 8550 40

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/01/2012 06/01/2012 6800.00 10,170,200.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Proppant Methenamine 100-97-0 1.00 0.08
Quartz 14808-60-7 70.00 5.95
AI-7NR Trican Well Service Corrosion Inhibitor Propargyl alcohol 107-19-7 1.00 0.00001000
WG-111D Trican Well Service Water Gellant Guar gum 9000-30-0 100.00 0.00222000
FEAC-20 Trican Well Service Iron Control Acetic acid 64-19-7 50.00 0.00156000
Citric acid 77-92-9 30.00 0.00094000
TXP-10 Trican Well Service Scale Inhibitor Acrylate phosphonate copolymer 40.00 0.01
1,2-Propylene glycol 57-55-6 10.00 0.00256000
Neutralized organic acid 20.00 0.00513000
Water 7732-18-5 70.00 0.01
Sand (Proppant) Trican Well Service Proppant
WXB-10 Trican Well Service Fracturing Crosslinker Ulexite 1319-33-1 60.00 0.00
Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.00
WBE-6 Trican Well Service Gel Breaker No hazardous ingredients 100.00 0.00
DF-1 Trican Well Service Defoaming Agent Non-hazardous materials only in the product 100.00 0.00
CS-1 Trican Well Service Clay Stabilizer Inorganic salts 30.00 0.06
Blend 25.00 0.05
1,2-Propylene glycol 57-55-6 20.00 0.04
Surfactant 5.00 0.01
WBO-2 Trican Well Service Gel Breaker Sodium persulfate 7775-27-1 100.00 0.00061000
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100.00 90.76
Acid, Hydrochloric (15) Trican Well Service General Acidizing
TXP-8 Trican Well Service Friction Reducer Cationic water-soluble polymer emulsion 100.00 0.08
GBO-1 Trican Well Service Gel Breaker Sodium perborate tetrahydrate 10486-00-7 100.00 0.00
Spectrachem tracer Diagnostics
Acid, Hydrochloric (7.5) General Acidizing
Acid, Hydrochloric (7.5) Trican Well Service General Acidizing Water 7732-18-5 92.50 0.31
Hydrochloric acid 7647-01-0 7.50 0.02
BioClear 5000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 10.00 0.00535000
Polyethylene glycol 25322-68-3 70.00 0.03
Acid, Hydrochloric (15) General Acidizing Hydrochloric acid 7647-01-0 15.00 0.00
Water 7732-18-5 85.00 0.00
BXL-A Trican Well Service Gel Breaker Proprietary 70.00 0.00
Spectrachem tracer ProTechnics Diagnostics Sodium Salt 10.00 0.00006000
Water 7732-18-5 90.00 0.00058000

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 ANADARKO E & P ONSHORE LLC Brine 12787 121
2013 ANADARKO E & P ONSHORE LLC Brine 1031 154
2014 ARTEX OIL COMPANY Brine 1273 364
2015 ARTEX OIL COMPANY Brine 3119 365
2016 ARTEX OIL COMPANY Brine 1950 366
2017 ARTEX OIL COMPANY Brine 1450 365
2018 ARTEX OIL COMPANY Brine 1425 365
2019 ARTEX OIL COMPANY Brine 300 90

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1034969234 2012-10-9 0:00: CT No Violations 1.00
-1087161208 2019-12-10 0:00 PW No Violations 0.30
-1172395589 2013-5-2 0:00:0 PW No Violations 1.50
-1252252928 2012-11-8 0:00: CT No Violations 2.00
-1575787965 2012-9-12 0:00: AM No Violations
-178092893 2013-8-7 0:00:0 PL No Violations 1.00
-2089415231 2012-10-9 0:00: CT No Violations 1.00
-2127039464 2012-2-17 0:00: DD No Violations 2.00
-486662796 2012-4-27 0:00: DD No Violations 2.00
-535935049 2013-5-29 0:00: PW No Violations 1.00
-583561022 2012-4-27 0:00: DD No Violations 5.00
-639013399 2012-11-8 0:00: PW No Violations
-662670289 2012-6-6 0:00:0 CT No Violations 3.00
-759204864 2012-4-13 0:00: DD No Violations 3.00
-763021214 2013-2-5 0:00:0 AD No Violations
0178092893 2013-08-07 Preliminary Restoration No Violations Preliminary Restoration passed on day of 8-7-13 on the inspection by Patrick Shreve.
0232743937 2012-04-19 Drill / Deepen / Reopen No Violations On day of inspection Key rig #9 is drilling at rate of 7per hour. The depth is at 11,000ft.
0371416617 2012-08-22 Completion Testing No Violations Service rig is swabbing well. The well is slowly starting to kick off.
0486662796 2012-04-27 Drill / Deepen / Reopen No Violations On day of inspection rig is trying to get 5.5 casing in the well. The rig had to run 400to Total depth of 12871.Will wait on phone call.
0535935049 2013-05-29 Production Wells No Violations I inspected site and Mclaughlin was in installing tanks and production equipment on the well pad. I will look at later to complete a preliminary restoration.
0583561022 2012-04-27 Drill / Deepen / Reopen No Violations Halliburton is on site to cement 12,450of 5.5casing in place. Rig could not get pipe down. The rig could not get pipe all the way to total depth.
0639013399 2012-11-08 Production Wells No Violations On site with training group from Central Office conducting inspection of producing Utica Shale well site, well is equipped with tubing and rods and pumping unit and currently producing into three 500 bbl frac tanks.
0662670289 2012-06-06 Completion Testing No Violations Trican was fracing well and was in between stages 12 and 13.Braek down pressure was 6755psi and7057psi.Between 90 and 94 barrel per minute was average rate.
0759204864 2012-04-13 Drill / Deepen / Reopen No Violations On day of inspection pipe was tripped out and new down hole drill motor and drill bit being installed.
0763021214 2013-02-05 Annular Disposal No Violations I accompanied Pat Shreve on the inspection of this well.
1034969234 2012-10-09 Completion Testing No Violations Jake Glasscock and I stopped in to look at well . Express Energy services are looking after well now. They stated that the well is making good oil. They are burning 2 flares. The well with pumping unit engaged will want kick off.
1078565079 2013-01-30 Production Wells No Violations Well is completed and ready to go in line. Waiting on tanks to be installed and production equipment. Well is equipped with a 660 pumping unit. Gates have been installed.
1172395589 2013-05-02 Production Wells No Violations On day of inspection Rick Trippel, Mallory Stanton, Teresa McQuade and I stopped in to look at well. Company is waiting on ROC Service company to come in and hook up tanks and facility.
1252252928 2012-11-08 Completion Testing No Violations On day of inspection the tour of the Columbus staff was purpose of being on site. Brad Millikan and Matt Carmichael and Steve Dimon met with the group and answered any questions. Well is being flowed back and developed.
1337095417 2012-05-15 Completion Testing No Violations On day of inspection the Christmas tree is in place and testing equipment is in place getting reading for frac job.
1339860964 2012-06-11 Completion Testing No Violations Coiled tubing unit is drilling out plugs after the frac job.
1347971962 2012-09-18 Completion Testing No Violations Well is being tested. Upon flare of well and flowing back into 500 barrel tank the tank started to expand. The material was contained and disposed of. The company is testing and find out the cause of the tank expanding. There were pressure relief hatches on the tank. There could have been a chemical reaction. The tank was used for emulsion purposes.
1358451298 2013-01-17 Completion Testing No Violations On day of inspection flow back is completed and company is moving equipment off of drill pad. Well will need electric hooked up. Company will have to install production system at production pad.
1575787965 2012-09-12 Administrative Inspection No Violations Bob Pitt with Anadarko called and they would be flaring well in the evening of 9-12-12. Local 911 was called and advised of the flare.
1805808688 2012-08-08 Completion Testing No Violations Company is getting ready to flow back well. The equipment will be coming in soon.
1863797987 2013-07-10 Completion Testing No Violations Brad Sellers and I went to the well site and looked at the production equipment. The Well is still shut in and the gas line has not been hooked up the salesline. There are men still working on the unit. I will check back at a later date for the preliminary.
2004520298 2012-09-11 Completion Testing No Violations Well is equipped with a 640 artificial lift unit. Edge is waiting on electric motor for unit. Edge is flow back group that will be performing flow back operations on well.
2046561174 2019-12-10 0:00 PW No Violations 0.20
2089415231 2012-10-09 Completion Testing No Violations I accompanied Pat Shreve on a field inspection where we found the well to be flaring and well not pumping. The company man stated they were waiting on the electrician to show and stated the well was making good amounts of oil.
2127039464 2012-02-17 Drill / Deepen / Reopen No Violations On day of inspection Ziggenfuss is drilling at depth of 220in 19open hole.Company set 140of conductor that was 20pipe.Spudded on 2-16-12.
232743937 2012-4-19 0:00: DD No Violations 2.50
371416617 2012-8-22 0:00: CT No Violations 1.00

For data sources see[7]