If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-21377 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.75,"lon":-81.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Sharon Township | |
Operator Name: GREEN GAS CO | |
Well Pad ID: | |
Farm/Lease Name: OHIO POWER | |
License Status: Producing | |
License Date: 1982-07-13 | |
Spud Date: 1969-12-06 | |
Spud Drilling Contractor: | |
Final Drill Date: 1970-02-22 | |
Well Total Depth: 5640.00 ft | |
Configuration: Vertical | |
Latitude: 39.750000 | |
Longitude: -81.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1969-12-06 | |
Completed | 1970-02-22 | |
Reached Total Depth | 1970-02-22 | |
CO | 1982-07-13 | 201 GREEN GAS CO GeoDate 7/13/82 |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5401 | 5536 | 18 |
5401 | 5536 | 18 | |
5401 | 5536 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 4000 Bbl | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | NOBLE GAS CO | 3058.00 | 0.00 | 0 |
1985 | NOBLE GAS CO | 5478.00 | 0.00 | 0 |
1986 | NOBLE GAS CO | 3300.00 | 0.00 | 365 |
1987 | NOBLE GAS CO | 5045.00 | 0.00 | 365 |
1988 | NOBLE GAS CO | 5563.00 | 0.00 | 365 |
1989 | NOBLE GAS CO | 5661.00 | 0.00 | 365 |
1990 | NOBLE GAS CO | 3541.00 | 0.00 | 365 |
1991 | NGO DEVELOPMENT CORP. | 3239.00 | 0.00 | 365 |
1992 | GREEN GAS CO | 10543.00 | 20.00 | 365 |
1993 | GREEN GAS CO | 7426.00 | 0.00 | 365 |
1994 | NOBLE GAS CO | 4475.00 | 0.00 | 365 |
1995 | NOBLE GAS CO | 4359.00 | 0.00 | 365 |
1996 | NOBLE GAS CO | 2802.00 | 0.00 | 365 |
1997 | NOBLE GAS CO | 2540.00 | 0.00 | 365 |
1998 | GREEN GAS CO | 1628.00 | 0.00 | 365 |
1999 | GREEN GAS CO | 1334.00 | 0.00 | 360 |
2000 | GREEN GAS CO | 2071.00 | 0.00 | 365 |
2001 | GREEN GAS CO | 1152.00 | 28.00 | 365 |
2002 | GREEN GAS CO | 939.00 | 0.00 | 365 |
2003 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2004 | GREEN GAS CO | 1704.00 | 0.00 | 365 |
2005 | GREEN GAS CO | 2171.00 | 0.00 | 365 |
2006 | GREEN GAS CO | 1559.00 | 0.00 | 365 |
2007 | GREEN GAS CO | 1027.00 | 0.00 | 365 |
2008 | GREEN GAS CO | 437.00 | 0.00 | 365 |
2009 | GREEN GAS CO | 1299.00 | 0.00 | 365 |
2010 | GREEN GAS CO | 1528.00 | 0.00 | 365 |
2011 | GREEN GAS CO | 429.00 | 0.00 | 0 |
2012 | GREEN GAS CO | 79.00 | 0.00 | 366 |
2013 | GREEN GAS CO | 433.00 | 0.00 | 365 |
2014 | GREEN GAS CO | 279.00 | 0.00 | 365 |
2015 | GREEN GAS CO | 252.00 | 0.00 | 365 |
2016 | GREEN GAS CO | 39.00 | 0.00 | 365 |
2017 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2018 | GREEN GAS CO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | NOBLE GAS CO | Brine | 0 | 0 |
1985 | NOBLE GAS CO | Brine | 0 | 0 |
1986 | NOBLE GAS CO | Brine | 0 | 365 |
1987 | NOBLE GAS CO | Brine | 0 | 365 |
1988 | NOBLE GAS CO | Brine | 0 | 365 |
1989 | NOBLE GAS CO | Brine | 0 | 365 |
1990 | NOBLE GAS CO | Brine | 0 | 365 |
1991 | NGO DEVELOPMENT CORP. | Brine | 25 | 365 |
1992 | GREEN GAS CO | Brine | 0 | 365 |
1993 | GREEN GAS CO | Brine | 25 | 365 |
1994 | NOBLE GAS CO | Brine | 0 | 365 |
1995 | NOBLE GAS CO | Brine | 40 | 365 |
1996 | NOBLE GAS CO | Brine | 50 | 365 |
1997 | NOBLE GAS CO | Brine | 0 | 365 |
1998 | GREEN GAS CO | Brine | 0 | 365 |
1999 | GREEN GAS CO | Brine | 0 | 360 |
2000 | GREEN GAS CO | Brine | 0 | 365 |
2001 | GREEN GAS CO | Brine | 0 | 365 |
2002 | GREEN GAS CO | Brine | 0 | 365 |
2003 | GREEN GAS CO | Brine | 0 | 0 |
2004 | GREEN GAS CO | Brine | 0 | 365 |
2005 | GREEN GAS CO | Brine | 0 | 365 |
2006 | GREEN GAS CO | Brine | 127 | 365 |
2007 | GREEN GAS CO | Brine | 0 | 365 |
2008 | GREEN GAS CO | Brine | 0 | 365 |
2009 | GREEN GAS CO | Brine | 0 | 365 |
2010 | GREEN GAS CO | Brine | 0 | 365 |
2011 | GREEN GAS CO | Brine | 0 | |
2012 | GREEN GAS CO | Brine | 177 | 366 |
2013 | GREEN GAS CO | Brine | 0 | 365 |
2014 | GREEN GAS CO | Brine | 0 | 365 |
2015 | GREEN GAS CO | Brine | 0 | 365 |
2016 | GREEN GAS CO | Brine | 0 | 365 |
2017 | GREEN GAS CO | Brine | 0 | 0 |
2018 | GREEN GAS CO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1836186224 | 2003-12-10 0:00 | PW | No Violations | |
-1945696490 | 2015-6-3 0:00:0 | PW | No Violations | 2.00 |
-1980474958 | 2012-6-20 0:00: | PW | No Violations | |
0011477019 | 2002-09-23 | Production Wells | No Violations | |
0145248200 | 2019-03-13 | Production Wells | No Violations | On the day of my inspection I witnessed production equipment included a 100-barrel steel production fluid storage tank, and horizontal separator. There was no earthen containment around the tank or separator. There was an additional horizontal separator near the production equipment that appears to be for 34121237100000 and a 2-inch diameter meter run with chart recorder approximately 100 feet north of the separators, the valves were slightly open, but the sales line had been disconnected and the chart recorder was no longer in use. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter intermediate casing, 2.875-inch diameter production casing and 1.5-inch diameter tubing utilizing a plunger lift system as means of production. The 4.5-inch diameter casing was no longer hooked to the flow line, the 2.875-inch diameter production string appeared to be providing domestic gas through a little joe regulator and 1-inch diameter plastic line. All the commercial production valves were closed at the time of my inspection and production was reported as 0 for 2017 and 2018. There was no identification on the production equipment or well head. I will contact Green Gas Company and inform them of the problems with the well and determine what they plan to do with the well in the future. |
0689723178 | 2004-03-15 | Production Wells | No Violations | No violations noted on the day of my inspection. |
0899630391 | 2017-10-05 | Production Wells | No Violations | The purpose of my inspection today was a status check on a production well. During my inspection the well was equipped with 4.5 inch diameter casing with a casing head, 2.875 inch diameter intermediate casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. Commercial production valves were in the closed position. A domestic gas line is attached to the 4.5 inch diameter casing with and open valve, regulator, and one drip. The production equipment consisted of one 100 barrel tank and one horizontal separator. Production records were current. |
11477019 | 2002-9-23 0:00: | PW | No Violations | |
1432043659 | 2015-05-19 | Production Wells | Violations Noted | My inspection finds the well is equipped with a plunger lift system. The production valves are open. A 100 barrel tank is set 144 from the wellhead and 396 from the traveled portion of Brookfield Township Road 52 in violation of 1509:9-9-05(A)(2). An adjacent tank battery, shared with another well on the lease, contains one 210 barrel tank with a leak. An area of oil saturated soil approximately 5 by 3 is present at the base of the 210 tank. Clean the oil saturated area and repair or remove the tank to prevent further contamination. Move the tank that is in violation of spacing requirements to an appropriate distance from the wellhead and the road. |
145248200 | 2019-3-13 0:00: | PW | No Violations | 1.50 |
1818622298 | 2012-04-28 | Production Wells | No Violations | Inspection of well head found the following equipment -4.5 production casing -2.875 tubing with in line valve on tubing & well is selling gas with current chart in meter -210 tank and separator present near wellhead . |
1836186224 | 2003-12-10 | Production Wells | No Violations | No violations noted,I.D. will need to be refreshed before long starting to fade out. |
1945696490 | 2015-06-03 | Production Wells | No Violations | My inspection today finds The 100 barrel tank has been moved to meet set back requirements. The 210 barrel tank has been removed and the small area of contamination remediated. The previous violation has been resolved. |
1980474958 | 2012-06-20 | Production Wells | No Violations | Thompson well service on location swabbing 2.875 intermediate string preparing to run 1.5 tubing in hole. |
689723178 | 2004-3-15 0:00: | PW | No Violations | |
899630391 | 2017-10-5 0:00: | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1432043659 | US-OH-112637 | 2015-06-22 | Well operation causing pollution and contamination | |
1432043659 | US-OH-112638 | 2015-06-22 | Violation of tank spacing requirements |
For data sources see[9]