{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.7,"lon":-81.53,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Olive Township | |
Operator Name: GREEN GAS CO | |
Well Pad ID: | |
Farm/Lease Name: FRANK WOODFORD A SHIRLEY & LARY E | |
License Status: Producing | |
License Date: 1979-11-28 | |
Spud Date: 1900-01-01 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 39.700000 | |
Longitude: -81.530000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1979-11-28 | 278 PRICE GREGG CORP GeoDate 11/28/79 |
CO | 1996-01-11 | 201 GREEN GAS CO GeoDate 11/28/79 |
Record Last Modified | 2017-02-10 | R.I. & R.L. 11-28-79 PERMIT EXPIRED. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | GREEN GAS CO | 0.00 | 0.00 | 30 |
1996 | GREEN GAS CO | 5388.00 | 0.00 | 365 |
1997 | GREEN GAS CO | 3730.00 | 33.00 | 365 |
1998 | GREEN GAS CO | 4232.00 | 24.00 | 365 |
1999 | GREEN GAS CO | 3510.00 | 25.00 | 365 |
2000 | GREEN GAS CO | 3556.00 | 134.00 | 365 |
2001 | GREEN GAS CO | 3718.00 | 0.00 | 365 |
2002 | GREEN GAS CO | 3666.00 | 0.00 | 365 |
2003 | GREEN GAS CO | 594.00 | 0.00 | 365 |
2004 | GREEN GAS CO | 4005.00 | 0.00 | 365 |
2005 | GREEN GAS CO | 2359.00 | 0.00 | 365 |
2006 | GREEN GAS CO | 2814.00 | 22.00 | 365 |
2007 | GREEN GAS CO | 2517.00 | 30.00 | 365 |
2012 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2013 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2014 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2016 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2017 | GREEN GAS CO | 0.00 | 0.00 | 0 |
2018 | GREEN GAS CO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | GREEN GAS CO | Brine | 45 | 30 |
1996 | GREEN GAS CO | Brine | 0 | 365 |
1997 | GREEN GAS CO | Brine | 0 | 365 |
1998 | GREEN GAS CO | Brine | 70 | 365 |
1999 | GREEN GAS CO | Brine | 0 | 365 |
2000 | GREEN GAS CO | Brine | 0 | 365 |
2001 | GREEN GAS CO | Brine | 0 | 365 |
2002 | GREEN GAS CO | Brine | 0 | 365 |
2003 | GREEN GAS CO | Brine | 0 | 365 |
2004 | GREEN GAS CO | Brine | 0 | 365 |
2005 | GREEN GAS CO | Brine | 0 | 365 |
2006 | GREEN GAS CO | Brine | 0 | 365 |
2007 | GREEN GAS CO | Brine | 0 | 365 |
2012 | GREEN GAS CO | Brine | 0 | 0 |
2013 | GREEN GAS CO | Brine | 0 | 0 |
2014 | GREEN GAS CO | Brine | 0 | 0 |
2016 | GREEN GAS CO | Brine | 0 | 0 |
2017 | GREEN GAS CO | Brine | 0 | 0 |
2018 | GREEN GAS CO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1396639212 | 2012-5-10 0:00: | PW | No Violations | |
-507679591 | 2017-2-13 0:00: | PW | No Violations | 1.00 |
-811251261 | 2014-3-13 0:00: | PW | No Violations | 1.00 |
0235840681 | 2016-06-16 | Production Wells | No Violations | My inspection finds the well is equipped with 4.5 casing and 1.5 tubing with a plunger lift system. No pipelines are attached to the well. The well is shut in. The tank battery is comprised of one 100 bbl tank and two production units. Photos were taken. |
0490124070 | 2013-03-19 | Production Wells | No Violations | My inspection today finds the status of the well has not changed. The well is shut in and not connected to any pipelines. |
0507679591 | 2017-02-13 | Production Wells | No Violations | The purpose of my inspection today is a status check on a compliance notice numbered 724809838 that was sent to Green Gas Company. The compliance notice stated that the well is in violation of 1501:9-9-05(10), 1509.62(A), and 1509.12(A). During my inspection the well was equipped with 8.625 inch diameter surface casing, 4.5 inch diameter production casing, 1.5 inch diameter tubing, and a plunger lift system. The tubing valve is closed and the production valve is closed. The production equipment consists of one 100 barrel tank and two gas production units. The well is idle. There has been no action taken to gain compliance. |
0724809838 | 2011-07-07 | Production Wells | Violations Noted | Upon inspecting site at request of land owner Larry Woodford found well to be idle and no production has been reported on well since it was drilled in 1983,all valves at well head were shut on the day of my inspection and no domestic hook ups were noted.
PLUG OR PRODUCE WELL OR FILE FOR INACTIVE STATUS. FAILURE TO COMPLY MAY RESULT IN BOND FORFIETURE. |
0811251261 | 2014-03-13 | Production Wells | No Violations | My inspection finds the well is equipped with 4.5 casing and 1.5 tubing with a plunger lift system. No pipelines are attached to the well. The well is shut in. The tank battery is comprised of one 100 bbl tank and two production units. |
0932228551 | 2014-09-16 | Administrative Inspection | No Violations | I stopped at Green Gass shop and spoke to Scott Davis field superintendent. Mr. Davis stated that the company was applying for a plugging permit. |
1023129131 | 2018-01-10 | Production Wells | No Violations | The purpose of my inspection was a follow up on a compliance notice numbered 724809838. The compliance notice stated that the well is in violation of 1501:9-9-05(A)(10) Failure to legibly identify well, 1509.062(A) Nonproduction, and 1509.12(A) Defective casing, leaking well. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. All production valves were in the closed position and no production lines were attached to the well. The disconnected production equipment consisted of one 100 barrel tank and two horizontal separators. Green Gas Company reported zeros for production for the years 2012 through to 2016. Pictures were taken to assist this inspection. |
1396639212 | 2012-05-10 | Production Wells | No Violations | Follow up inspection on NOV issued by Inspector Dave Ball ,no change in status well still idle . |
1494855358 | 2017-05-15 | Production Wells | No Violations | The purpose of my inspection was a follow up on a compliance notice numbered 724809838 that was sent to Green Gas Company. The compliance notice stated that the well is in violation of 1501:9-9-05(A)(10) Failure to legibly identify well, 1509.062(A) Nonproduction, and 1509.12(A) Defective casing, leaking well. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. The tubing valve is closed and the production valve is closed. The production equipment consists of one 100 barrel tank and two gas production units. The well is idle. There has been no action taken to gain compliance and all the original violations still exist. |
1534332599 | 2018-08-14 | Production Wells | No Violations | The purpose of my inspection was a follow up on compliance notice 724809838. During my inspection the well was equipped with 8.625-inch diameter surface casing with a casing head, 4.5-inch diameter production casing with a tubing head, 1.5-inch diameter tubing, and a plunger lift system. All production valves were in the closed position and no production lines were attached to the well. The disconnected production equipment consisted of two 100-barrel tanks and two horizontal separators. Tank battery is shared with 3412123027. Green Gas Company reported zeros for production for the years 2012 through to 2017. |
1596647237 | 2020-8-5 0:00:0 | PW | No Violations | 0.50 |
1629408836 | 2011-10-03 | Production Wells | No Violations | No change in status of well it still remains idle. |
1669306932 | 2015-09-24 | Production Wells | No Violations | I am accompanied today by Inspector Sefcik, our inspection finds the well is shut in and there are no pipe lines attached to the well. The tank battery consists of one 100 barrel tank and two horizontal separators. Photos were taken. |
1674462919 | 2015-09-29 | Administrative Inspection | No Violations | At 2:29 pm I received a call from Scott Davis in response to a voice mail I left. Mr. Davis and I discussed the companys plans for the well. Mr. Davis stated that he was going plug the well. I reminded Mr. Davis that the well has been in violation for more than four years and that the company may face escalated enforcement action if not addressed quickly. |
1835247779 | 2019-6-11 0:00: | PW | No Violations | 1.00 |
2087137286 | 2019-03-04 | Production Wells | No Violations | The purpose of my inspection was to follow up on a previously issued compliance notice. On the day of my inspection I witnessed production equipment included a 100-barrel production fluid storage tank, and horizontal separator. There was an additional horizontal separator in the production area. The earthen containment around the production equipment was no longer intact, and it appeared that some recent pipeline work had been done around the production equipment. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, and 1.5-inch diameter tubing utilizing a plunger lift system as means of production. The flow line was no longer attached and the well appeared to be idle at the time of my inspection. Identification tags were present but illegible, and production was reported as 0 since 2012. Photographs were taken to assist with the inspection. |
2120787481 | 2020-1-13 0:00: | PW | No Violations | 1.00 |
235840681 | 2016-6-16 0:00: | PW | No Violations | 1.00 |
490124070 | 2013-3-19 0:00: | PW | No Violations | 1.00 |
724809838 | 2011-7-7 0:00:0 | PW | No Violations | |
932228551 | 2014-9-16 0:00: | AM | No Violations | 0.20 |
986317287 | 2020-1-13 0:00: | PW | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0724809838 | US-OH-128246 | 2011-07-10 | Failure to legibly identify well | |
0724809838 | US-OH-128247 | 2011-07-10 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
0724809838 | US-OH-128248 | 2011-07-10 | Defective casing, leaking well |