Well ID: 34-121-21704 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.84,"lon":-81.57,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Buffalo Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: SPIKER DONALD & MOORE ROY | |
License Status: Producing | |
License Date: 1983-05-04 | |
Spud Date: 1974-08-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 1974-08-21 | |
Well Total Depth: 5438.00 ft | |
Configuration: Vertical | |
Latitude: 39.840000 | |
Longitude: -81.570000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1974-08-10 | PERMIT EXPIRED. |
Completed | 1974-08-21 | PERMIT EXPIRED. |
Reached Total Depth | 1974-08-21 | PERMIT EXPIRED. |
CO | 1982-01-01 | 2815 AVA GAS CORP GeoDate 1/1/82 |
CO | 1983-05-04 | 2815 AVA GAS CORP GeoDate 5/4/83 |
Oil and Gas | 1983-05-04 | Issued Date 5/4/83 Expired Date 10/31/83 Acres 0044000 Tool Type CRF Proposed Formation OHIO SHALE Proposed Depth 00000 Proposed Drill Depth 00000 |
Plugged Back | 1983-05-07 | PERMIT EXPIRED. |
Construction Permit Expires | 1983-10-31 | PERMIT EXPIRED. |
Change of Owner | 2006-03-30 | Operator changed from 2815, AVA GAS CORP to 1634, NORTHWOOD ENERGY CORP |
Record Last Modified | 2013-10-03 | PERMIT EXPIRED. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5258 | 5287 | 17 |
5258 | 5287 | 17 | |
5258 | 5287 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 500 Gal | 0 | |||
H2O | 0 | 1109 Bbl | 40000 | R.P. 48 HRS. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1987 | BUCKEYE OIL PRODUCING CO | 1652.00 | 0.00 | 365 |
1988 | BUCKEYE OIL PRODUCING CO | 2684.00 | 0.00 | 365 |
1989 | BUCKEYE OIL PRODUCING CO | 2391.00 | 0.00 | 365 |
1990 | BUCKEYE OIL PRODUCING CO | 1508.00 | 0.00 | 365 |
1991 | BUCKEYE OIL PRODUCING CO | 1729.00 | 30.00 | 365 |
1992 | AVA GAS CORP | 0.00 | 0.00 | 0 |
1993 | AVA GAS CORP | 0.00 | 0.00 | 365 |
1994 | AVA GAS CORP | 0.00 | 0.00 | 365 |
1995 | AVA GAS CORP | 0.00 | 0.00 | 365 |
1996 | AVA GAS CORP | 0.00 | 0.00 | 365 |
1997 | AVA GAS CORP | 0.00 | 0.00 | 365 |
1998 | AVA GAS CORP | 0.00 | 0.00 | 365 |
2005 | NORTHWOOD ENERGY CORP | 0.00 | 0.00 | 0 |
2006 | NORTHWOOD ENERGY CORP | 404.00 | 0.00 | 365 |
2007 | NORTHWOOD ENERGY CORP | 893.00 | 0.00 | 365 |
2008 | NORTHWOOD ENERGY CORP | 2582.00 | 0.00 | 365 |
2009 | NORTHWOOD ENERGY CORP | 2105.00 | 0.00 | 365 |
2010 | NORTHWOOD ENERGY CORP | 1659.00 | 0.00 | 365 |
2011 | NORTHWOOD ENERGY CORP | 10.00 | 17.00 | 0 |
2012 | NORTHWOOD ENERGY CORP | 1997.00 | 0.00 | 366 |
2013 | NORTHWOOD ENERGY CORP | 464.00 | 0.00 | 365 |
2014 | NORTHWOOD ENERGY CORP | 619.00 | 0.00 | 365 |
2015 | NORTHWOOD ENERGY CORP | 415.00 | 0.00 | 365 |
2016 | NORTHWOOD ENERGY CORP | 553.00 | 0.00 | 365 |
2017 | NORTHWOOD ENERGY CORP | 391.00 | 0.00 | 365 |
2018 | NORTHWOOD ENERGY CORP | 361.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1987 | BUCKEYE OIL PRODUCING CO | Brine | 0 | 365 |
1988 | BUCKEYE OIL PRODUCING CO | Brine | 0 | 365 |
1989 | BUCKEYE OIL PRODUCING CO | Brine | 0 | 365 |
1990 | BUCKEYE OIL PRODUCING CO | Brine | 0 | 365 |
1991 | BUCKEYE OIL PRODUCING CO | Brine | 45 | 365 |
1992 | AVA GAS CORP | Brine | 0 | 0 |
1993 | AVA GAS CORP | Brine | 0 | 365 |
1994 | AVA GAS CORP | Brine | 0 | 365 |
1995 | AVA GAS CORP | Brine | 0 | 365 |
1996 | AVA GAS CORP | Brine | 0 | 365 |
1997 | AVA GAS CORP | Brine | 0 | 365 |
1998 | AVA GAS CORP | Brine | 0 | 365 |
2005 | NORTHWOOD ENERGY CORP | Brine | 0 | 0 |
2006 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2007 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2008 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2009 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2010 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2011 | NORTHWOOD ENERGY CORP | Brine | 30 | |
2012 | NORTHWOOD ENERGY CORP | Brine | 0 | 366 |
2013 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2014 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2015 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2016 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2017 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2018 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-59009910 | 2019-4-9 0:00:0 | PW | No Violations | 1.00 |
0059009910 | 2019-04-09 | Production Wells | No Violations | On the day of my inspection I witnessed the well was equipped with 4.5-inch diameter production casing, with a 4.5-inch to 2-inch diameter swage nipple, 2-inch diameter valve that was in the open position, and it appeared that the well was tied directly into the sales line through a 1.25-inch diameter plastic line. There was a domestic gas hookup attached to the well head that was supplied through a little joe regulator, and rotary style domestic meter with the valves in the open position. Production equipment was no longer in use and consisted of 100-barrel steel production fluid storage, and horizontal separator, the flow line was no longer connected to the separator. The production area was overgrown with vegetation and there was no identification on the well or production equipment. Production was reported for 2017. I will contact Northwood Energy and inform them there needs to be identification posted on the well. |