34-121-22235

Well Details

Well ID: 34-121-22235
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Elk Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: BUTCHER STANLEY
License Status: Final Restoration
License Date: 2017-08-04
Spud Date: 1979-12-23
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1979-01-14
Well Total Depth: 2500.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1979-01-14 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.
Reached Total Depth 1979-01-14 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.
Original Spud 1979-12-23 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.
CO 1981-10-14 3927 WILMAR OIL & GAS GeoDate 10/14/81
Completion Report Received 1983-06-16 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.
Change of Owner 2003-01-27 Operator changed from 3927, WILMAR OIL & GAS to 1888, BECK ENERGY CORP
APP 2017-08-04 Proposed Formations:OHIO SHALE, Issued Date:8/4/2017, Expired Date:8/4/2019 12:00:00 PM, Drilling unit acres:36.13, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2018-04-16 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.
Construction Permit Expires 2019-08-04 UPDATE LOCATION PER DOGRM SURVEYOR 4/16/18 ALE.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-08-26 2390 2404 52
2390 2404 52
2390 2404 52

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TENDER EQUITY CORPORATION 13.00 0.00 365
2007 BECK ENERGY CORPORATION 21.00 4.00 0
2008 BECK ENERGY CORPORATION 6.00 0.00 365
2009 BECK ENERGY CORPORATION 7.00 0.00 365
2010 BECK ENERGY CORPORATION 7.00 0.00 365
2011 BECK ENERGY CORPORATION 65.00 0.00 365
2012 BECK ENERGY CORPORATION 0.00 0.00 0
2013 BECK ENERGY CORPORATION 94.00 0.00 365
2014 BECK ENERGY CORPORATION 126.00 0.00 365
2015 BECK ENERGY CORPORATION 128.00 0.00 365
2016 BECK ENERGY CORPORATION 93.00 0.00 365
2017 BECK ENERGY CORPORATION 31.00 0.00 365
2018 BECK ENERGY CORPORATION 74.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TENDER EQUITY CORPORATION Brine 0 365
2007 BECK ENERGY CORPORATION Brine 0
2008 BECK ENERGY CORPORATION Brine 0 365
2009 BECK ENERGY CORPORATION Brine 0 365
2010 BECK ENERGY CORPORATION Brine 0 365
2011 BECK ENERGY CORPORATION Brine 0 365
2012 BECK ENERGY CORPORATION Brine 0 0
2013 BECK ENERGY CORPORATION Brine 0 365
2014 BECK ENERGY CORPORATION Brine 0 365
2015 BECK ENERGY CORPORATION Brine 0 365
2016 BECK ENERGY CORPORATION Brine 0 365
2017 BECK ENERGY CORPORATION Brine 0 365
2018 BECK ENERGY CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1881662406 2019-8-15 0:00: FR No Violations
-1890418135 2019-6-4 0:00:0 PB No Violations 1.90
-1989795736 2004-12-20 0:00 PW No Violations
-2028090424 2019-5-31 0:00: PB No Violations 2.50
0561580542 2016-04-04 Production Wells No Violations My inspection today finds the well is equipped with a pumping unit. The pumping unit does not have any permanently set source of power. Valves at the wellhead are open. The tank battery consists of one fifty barrel tank and a meter with a current chart.
1049799635 2004-12-15 Production Wells Violations Noted Work at site nearing competition to become in compliance with previous violations will check back 12-20-04 .
1098527149 2004-10-18 Production Wells Violations Noted Upon receiving complaint from land owner Clark Butcher of wells in need of I.D.and clean up needed around production tank,and tank needs to be properly spaced from wellhead.Called Dave Keil of Beck Energy and advised him on violations at site he stated they had recently bought wells from Wilmar Oil Gas and was working their way to the Butcher lease.
1300797924 2012-02-22 Production Wells No Violations Upon inspection of the well head the following equipment was found 4.5 casing with valve open, 2.375 tubing with valve closed well is being produced by means of a pumping unit, At fluid storage area the following equipment is present 1-50 barrel tank a fluid separator and gas meter with proper well identification.
1346073959 2012-08-27 Production Wells No Violations My inspection this day finds the well is equipped with 4.5 casing, 2.375 tubing with rods, and a pump jack. The tank battery consists of 0ne 50 bbl tank and a meter. The production valves are open. The tank battery is shared with another well.
1890418135 2019-06-04 Plug / Plug Back No Violations

-inch 10 round tubing in the open borehole to a depth of 388 feet and cemented back to surface. Formation cementing services were on site performing the cement job. Formation ran 120 sacks of regular class A cement( Fairborn). They added 90 lbs. of cotton seed hulls to the cement and 100 lbs. of calcium chloride. Good circulation was established, and cement did not drop back.

1946151307 2011-03-04 Production Wells No Violations Inspection revealed that well is online and is being used for domestic purposes also, well is equipped with 4.5 production casing.

There is a pump jack and rods at site but not in use no tubing in well.

1989795736 2004-12-20 Production Wells Violations Noted Upon inspecting site found that well was placed back into production old 100bbl tank removed and cleanup was preformed at tank site,resolving prior violations.
2028090424 2019-05-31 Plug / Plug Back No Violations The inspection revealed that Harmon well service is rigged up over the well. Harmons ran 2298 feet of 10 round 2 3/8--1898 feet. The displacement is at 7.8 barrels of salt water at 9 lb. per gallon. The well broke circulation and circulated oil out into half round tank.
561580542 2016-4-4 0:00:0 PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1049799635 US-OH-100812 2004-10-23 Well operation causing pollution and contamination
1049799635 US-OH-100813 2004-10-23 Failure to legibly identify well
1049799635 US-OH-100814 2004-10-23 Violation of tank spacing requirements
1098527149 US-OH-102373 2004-10-23 Well operation causing pollution and contamination
1098527149 US-OH-102374 2004-10-23 Failure to legibly identify well
1098527149 US-OH-102375 2004-10-23 Violation of tank spacing requirements
1989795736 US-OH-120178 2004-10-23 Well operation causing pollution and contamination
1989795736 US-OH-120179 2004-10-23 Failure to legibly identify well
1989795736 US-OH-120180 2004-10-23 Violation of tank spacing requirements

For data sources see[9]