{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.71,"lon":-81.45,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Enoch Township | |
Operator Name: STONEBRIDGE OPERATING CO LLC | |
Well Pad ID: | |
Farm/Lease Name: NAU R | |
License Status: Producing | |
License Date: 1982-03-22 | |
Spud Date: 1982-03-27 | |
Spud Drilling Contractor: | |
Final Drill Date: 1982-04-05 | |
Well Total Depth: 6048.00 ft | |
Configuration: Vertical | |
Latitude: 39.710000 | |
Longitude: -81.450000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1982-03-22 | Issued Date 3/23/82 Expired Date 9/19/82 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06048 Proposed Drill Depth 06048 |
Original Spud | 1982-03-27 | |
Completed | 1982-04-05 | |
Reached Total Depth | 1982-04-05 | |
CO | 1982-04-09 | 2348 TRIAD RESOURCES INC GeoDate 3/22/82 |
Construction Permit Expires | 1982-09-19 | |
Completion Report Received | 1986-05-28 | |
CO | 1993-08-27 | 1019 VALENTINE OIL PROPERTIES GeoDate 3/22/82 |
CO | 1995-01-19 | 2070 HALWELL COMPANY GeoDate 3/22/82 |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5872 | 5931 | 17 |
5872 | 5931 | 17 | |
5872 | 5931 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 200 Mscf | 0 | |||
H2O | 0 | 76000 Gal | 60000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1938540912 | 2012-5-29 0:00: | PW | No Violations | |
0000PL7765 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0018801691 | 2018-03-09 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 1.5 inch diameter tubing, and a plunger lift system. Production valves were in the open position. The production equipment consisted of one 100 barrel tank, one drip and one horizontal separator. All equipment was within an earthen dike. The identification was located on the 100 barrel tank and the production records were current. |
1340882571 | 2012-06-28 | Production Wells | No Violations | Follow up on verbal request to properly identify well and repair gas leak at well head. Proper identification has been erected and attempt has been made to stop gas leak. |
18801691 | 2018-3-9 0:00:0 | PW | No Violations | 0.50 |
1938540912 | 2012-05-29 | Production Wells | No Violations | Inspection of the well found the following equipment -8.625 surface casing -4.5 production casing -1.5 tubing with the production valves open . A single 100 barrel tank -separator and gas meter are present in an established dike .Inspector will note well leaking gas from tubing slips and ID needs refreshed, will call company and ask for corrective action. |
2085155387 | 2014-02-24 | Production Wells | No Violations | My inspection finds the well appears to be shut in. The well is equipped to be produced by a plunger lift system. The tank battery is comprised of one 100 bbl tank, a separator, and a meter. |
PL7765 | PL | No Violations |