Well Details

Well ID: 34-121-22868
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Noble Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: SLATER GEORGE
License Status: Producing
License Date: 1982-07-30
Spud Date: 1982-08-28
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1982-09-04
Well Total Depth: 5597.00 ft
Configuration: Vertical
Latitude: 39.760000
Longitude: -81.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-07-30 28 CGAS EXPLORATION,INC GeoDate 7/30/82
Oil and Gas 1982-07-30 Issued Date 7/30/82 Expired Date 1/15/83 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05597 Proposed Drill Depth 05597
Original Spud 1982-08-28
Completed 1982-09-04
Reached Total Depth 1982-09-04
Completion Report Received 1982-09-20
Construction Permit Expires 1983-01-15
Change of Owner 1998-01-21 Operator changed from 28, CGAS EXPLORATION to 5352, ARTEX OIL COMPANY
Change of Owner 2008-05-27 Operator changed from 5352, ARTEX OIL COMPANY to 5815, JADCO ENERGY INC.
Change of Owner 2014-06-16 Operator changed from 5815, JADCO ENERGY INC to 1634, NORTHWOOD ENERGY CORP
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5341 5504 0
5341 5504 0
2006-09-11 5375 5409 8
5375 5409 8
5341 5504 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1482 Bbl 55000 FRAC;1482BBL H2O,55M# SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 YEI INC 34103.00 0.00 0
1985 YEI INC 32877.00 0.00 358
1986 YEI INC 16189.00 0.00 365
1987 YEI INC 10534.00 0.00 365
1988 YEI INC 8427.00 0.00 365
1989 CGAS EXPLORATION 8159.00 0.00 365
1990 CGAS EXPLORATION 7903.00 0.00 365
1991 CGAS EXPLORATION 6893.00 0.00 365
1992 CGAS EXPLORATION 2495.00 0.00 366
1993 CGAS EXPLORATION 2445.00 0.00 366
1994 CGAS EXPLORATION 0.00 0.00 365
1995 CGAS EXPLORATION 303.00 0.00 365
1996 CGAS EXPLORATION 883.00 0.00 365
1997 CGAS EXPLORATION 0.00 0.00 365
1999 ARTEX OIL COMPANY 299.00 75.00 0
2000 ARTEX OIL COMPANY 2252.00 0.00 365
2001 ARTEX OIL COMPANY 2160.00 56.00 365
2002 ARTEX OIL COMPANY 1463.00 0.00 365
2003 ARTEX OIL COMPANY 1894.00 48.00 365
2004 ARTEX OIL COMPANY 1308.00 0.00 365
2005 ARTEX OIL COMPANY 1254.00 0.00 365
2006 ARTEX OIL COMPANY 1332.00 0.00 365
2007 ARTEX OIL COMPANY 1437.00 0.00 365
2008 JADCO ENERGY INC 112.00 0.00 365
2009 JADCO ENERGY INC 851.00 0.00 365
2010 JADCO ENERGY INC 808.00 0.00 365
2011 JADCO ENERGY INC 1226.00 0.00 365
2012 JADCO ENERGY INC 929.00 0.00 366
2013 JADCO ENERGY INC 940.00 0.00 365
2014 NORTHWOOD ENERGY CORP 175.00 0.00 365
2015 NORTHWOOD ENERGY CORP 581.00 0.00 365
2016 NORTHWOOD ENERGY CORP 420.00 0.00 365
2017 NORTHWOOD ENERGY CORP 731.00 0.00 365
2018 NORTHWOOD ENERGY CORP 231.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 YEI INC Brine 0 0
1985 YEI INC Brine 0 358
1986 YEI INC Brine 0 365
1987 YEI INC Brine 0 365
1988 YEI INC Brine 105 365
1989 CGAS EXPLORATION Brine 28 365
1990 CGAS EXPLORATION Brine 0 365
1991 CGAS EXPLORATION Brine 35 365
1992 CGAS EXPLORATION Brine 0 366
1993 CGAS EXPLORATION Brine 0 366
1994 CGAS EXPLORATION Brine 0 365
1995 CGAS EXPLORATION Brine 0 365
1996 CGAS EXPLORATION Brine 0 365
1997 CGAS EXPLORATION Brine 38 365
1999 ARTEX OIL COMPANY Brine
2000 ARTEX OIL COMPANY Brine 17 365
2001 ARTEX OIL COMPANY Brine 0 365
2002 ARTEX OIL COMPANY Brine 345 365
2003 ARTEX OIL COMPANY Brine 55 365
2004 ARTEX OIL COMPANY Brine 0 365
2005 ARTEX OIL COMPANY Brine 0 365
2006 ARTEX OIL COMPANY Brine 0 365
2007 ARTEX OIL COMPANY Brine 0 365
2008 JADCO ENERGY INC Brine 0 365
2009 JADCO ENERGY INC Brine 0 365
2010 JADCO ENERGY INC Brine 0 365
2011 JADCO ENERGY INC Brine 0 365
2012 JADCO ENERGY INC Brine 0 366
2013 JADCO ENERGY INC Brine 0 365
2014 NORTHWOOD ENERGY CORP Brine 0 365
2015 NORTHWOOD ENERGY CORP Brine 0 365
2016 NORTHWOOD ENERGY CORP Brine 0 365
2017 NORTHWOOD ENERGY CORP Brine 0 365
2018 NORTHWOOD ENERGY CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1424126746 2019-4-12 0:00: PW No Violations 1.50
-1509233979 2018-12-28 0:00 PW No Violations 1.00
0000PL7731 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1041877225 2003-01-02 Production Wells No Violations Vault getting full called Co. they will send truck out to empty it!

Well appeared capable of production,no violations this inspection

1424126746 2019-04-12 Production Wells No Violations The purpose of my inspection was to follow up on previously issued compliance notice. Production equipment for the well included a 210-barrel steel production fluid tank, horizontal separator and 2-inch meter run with a .250-inch orifice, and drip. Also, in the production area was an additional horizontal separator, drip and a small natural gas compressing unit, there were oil filters and trash near the compressing unit. The additional horizontal separator was acting as a fluid drop out before the compressor. The production area also included 2 concrete brine vault tanks to the north of the steel production fluid storage tank, the brine tanks did not appear to be in use anymore but still contained fluid, all production equipment was enclosed within an earthen dike. The dike did not appear to be capable of holding fluid and is located near a steam. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, and 1.5-inch diameter tubing with a gate valve that was open, the flow line valve was slightly open, the flow line appeared to have been recently repaired and the well appeared to be producing. Identification was present and production was reported for 2017. I contacted Carl West operator for Northwood Energy and informed him of the issues that needed to be addressed, and updated landowner of the situation.
1509233979 2018-12-28 Production Wells No Violations The purpose of my inspection was to follow up on compliance number 1541539082. Production equipment for the well included a 210-barrel steel production fluid tank, horizontal separator and 2-inch meter run with a .250-inch orifice, and drip. Also, in the production area was an additional horizontal separator, drip and a small natural gas compressing unit. The additional horizontal separator was acting as a fluid drop out before the compressor. The production area also included 2 concrete brine tanks to the north of the steel production fluid storage tank, the brine tanks did not appear to be in use anymore, all production equipment was enclosed within an earthen dike. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, and 1.5-inch diameter tubing with a gate valve that was open. The well was still shut in at the time of my inspection and it did not appear that any remediation had been done since the compliance notice was issued. Identification was present and production was reported for 2017.
1541539082 2018-11-02 Production Wells Violations Noted The purpose of my inspection was to follow up on complaint number 6004. I received a phone call from Landowner Linda Slater who informed me that the well on her property had a gas leak between the well and production equipment. Linda explained that there were multiple leaks throughout the flow line, and the line had been leaking for a couple of months. I contacted ODNR Regional Supervisor Brent Bear and informed him of the complaint, Brent Informed me that he would accompany me during my investigation of the complaint. I spoke with Northwood Energy Corps Cory McCudden who informed me that they were aware of the problem, and had done multiple remediations on the flow line and the well was supposed to be shut in. Northwood Energy Corp sent out their operator for the well George Flowers who informed me that he had shut the well in several months ago and it was not supposed to be producing. Production equipment for the well included a 210-barrel steel production fluid tank, horizontal separator and 2-inch meter run with a .250-inch orifice, and drip. Also, in the production area was an additional horizontal separator, drip and a small natural gas compressing unit. The additional horizontal separator was acting as a fluid drop out before the compressor. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, and 1.5-inch diameter tubing with a gate valve that was open. The casing valve was closed, and the 2-inch diameter flow line valve was open at the time of my inspection. George Flowers the contract pumper for the well shut the 2-inch diameter flow line valve. Brent Bear and I remained on location to confirm the gas leak had stopped. Photographs were taken of the affected area and equipment. I informed Northwood Energy Corp Cory McCudden that the well can not be put back in production until the line is repaired and they needed to get the line repaired within 30 days.
1597551050 2018-08-06 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing with a tubing head, 1.5-inch diameter tubing, and a plunger lift system. The valve attached to the 4.5-inch diameter production casing was in the closed position. The Demco valve on the tubing and the ball valve on the sales line were in the open position. The production equipment consisted of one 210-barrel tank, one horizontal separator, and a sales meter. The sales meter had a 2-inch diameter sales line, a .25-inch orifice plate, and a chart recorder. The production equipment was located within an earthen dike that was shared with a small compressor and a horizontal separator labeled Jadco Energy. The compressor was in operation during inspection. Northwood Energy has submitted reports of gas production for the year 2017. Identification was located on the 210-barrel tank.
PL7731 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1541539082 US-OH-114909 2019-05-13 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]

References