34-121-23062

Well Details

Well ID: 34-121-23062
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Jackson Township
Operator Name: G-R CONTRACTING INC
Well Pad ID:
Farm/Lease Name: D MORRIS
License Status: Final Restoration
License Date: 2016-10-25
Spud Date: 1983-11-29
Spud Drilling Contractor: J & B DRILLING
Final Drill Date: 1983-12-07
Well Total Depth: 6129.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -81.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-09-22 6 BENATTY CORP GeoDate 9/22/83
Oil and Gas 1983-09-22 Issued Date 9/22/83 Expired Date 3/20/84 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06129 Proposed Drill Depth 06129
Original Spud 1983-11-29 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Completed 1983-12-07 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Reached Total Depth 1983-12-07 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Completion Report Received 1984-01-18 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
CO 1995-01-20 182 BELDEN & BLAKE CO GeoDate 9/22/83
Change of Owner 1998-06-12 Operator changed from 182, BELDEN & BLAKE CORPORATION to 5352, ARTEX OIL COMPANY
Change of Owner 2003-05-06 Operator changed from 5352, ARTEX OIL COMPANY to 952, G-R CONTRACTING INC
Last Compliance Report 2016-08-22 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Plugged/Abandoned 2016-10-13 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
APP 2016-10-25 Proposed Formations:CLINTON SAND, Issued Date:10/25/2016, Expired Date:10/25/2018 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:TAAD, Proposed Well Class:
Record Last Modified 2017-12-13 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.
Construction Permit Expires 2018-10-25 UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 12/13/17.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5830 5884 18
5830 5884 18
2006-09-11 5940 5951 12
5940 5951 12
5830 5884 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 152500 Mscf 0 MEDINA
H2O 0 39000 Gal 35000 CLINTON
H2O 0 39000 Gal 40000 FRAC; FLUID,SAND,&N2
N2 0 133 Mscf 0 CLINTON

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BENATTY CORP 14283.00 0.00 0
1985 BENATTY CORP 7479.00 0.00 0
1986 BENATTY CORP 3605.00 0.00 365
1987 BENATTY CORP 4281.00 0.00 365
1988 BENATTY CORP 3243.00 0.00 365
1989 BENATTY CORP 3348.00 0.00 365
1990 BENATTY CORP 2469.00 0.00 365
1991 BENATTY CORP 2245.00 0.00 365
1992 BENATTY CORP 1463.00 0.00 365
1993 BENATTY CORP 1513.00 0.00 365
1994 BELDEN & BLAKE CORPORATION 1100.00 0.00 31
1995 BELDEN & BLAKE CORPORATION 384.00 0.00 49
1999 ARTEX OIL COMPANY 0.00 0.00 0
2000 ARTEX OIL COMPANY 0.00 0.00 365
2001 ARTEX OIL COMPANY 0.00 0.00 365
2002 G-R CONTRACTING INC 0.00 0.00 365
2003 G-R CONTRACTING INC 0.00 0.00 365
2004 G-R CONTRACTING INC 0.00 0.00 365
2005 G-R CONTRACTING INC 0.00 0.00 365
2006 G-R CONTRACTING INC 0.00 0.00 365
2012 G-R CONTRACTING INC 0.00 0.00 366
2013 G-R CONTRACTING INC 131.00 0.00 365
2014 G-R CONTRACTING INC 0.00 0.00 365
2015 G-R CONTRACTING INC 0.00 0.00 365
2016 G-R CONTRACTING INC 1236.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BENATTY CORP Brine 0 0
1985 BENATTY CORP Brine 195 0
1986 BENATTY CORP Brine 0 365
1987 BENATTY CORP Brine 150 365
1988 BENATTY CORP Brine 0 365
1989 BENATTY CORP Brine 150 365
1990 BENATTY CORP Brine 150 365
1991 BENATTY CORP Brine 0 365
1992 BENATTY CORP Brine 120 365
1993 BENATTY CORP Brine 0 365
1994 BELDEN & BLAKE CORPORATION Brine 60 31
1995 BELDEN & BLAKE CORPORATION Brine 0 49
1999 ARTEX OIL COMPANY Brine
2000 ARTEX OIL COMPANY Brine 0 365
2001 ARTEX OIL COMPANY Brine 0 365
2002 G-R CONTRACTING INC Brine 0 365
2003 G-R CONTRACTING INC Brine 0 365
2004 G-R CONTRACTING INC Brine 0 365
2005 G-R CONTRACTING INC Brine 0 365
2006 G-R CONTRACTING INC Brine 0 365
2012 G-R CONTRACTING INC Brine 0 366
2013 G-R CONTRACTING INC Brine 0 365
2014 G-R CONTRACTING INC Brine 0 365
2015 G-R CONTRACTING INC Brine 0 365
2016 G-R CONTRACTING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1420408808 2016-10-11 0:00 PB No Violations 8.00
-641963773 2016-9-29 0:00: PB No Violations 4.00
-842877345 2016-8-8 0:00:0 PW No Violations 1.00
0000PL7660 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0003476989 2002-08-05 Production Wells No Violations
0641963773 2016-09-29 Plug / Plug Back No Violations G-R Contracting used their service rig to attempt to get a hold of the 1.5 tubing setting 4 from the top of the 4.5 casing wellhead. The overshot tool was unable to retrieve the pipe. Appalachian Wireline Surveys attempted to run a collar locator tool down the tubing, but only made it to a depth of 3036.
0648290986 2016-10-13 Plug / Plug Back No Violations During my inspection today Formations Cementing set a 200 foot isolation plug with Class A cement in the 7.875 inch diameter open hole from 3940 feet to 3740 feet. G-R contracting pulled 51 joints of the 4.5 inch diameter casing to 1967 feet. Formations set a 200 foot bottom of surface plug with Class A cement from 1967 feet to 1776 feet. G-R pulled the 4.5 inch diameter casing to 200 foot. Formations cementing set a 200 foot surface plug with Class A cement with 2% calcium. G-R pulled the remaining 4.5 inch casing from the hole. The surface plug dropped and Formations set an additional 125 foot surface plug with Class A cement with 2% calcium. Cement stayed at surface.
0726455424 2016-07-19 Temporary Abandoned Annular Disposal No Violations My inspection today finds the annular disposal is not in use. The well is equipped with 4.5 casing and 1.5 tubing. Both valves on the 4.5 by 1.5 tubing head have rotted off and are laying at the base of the well. Also, the wellhead is very badly corroded, which is consistent with being affected by H2S. The 1.5 tubing and plunger lift lubricator have broken off at the top of the wellhead. There are no means of well control on the 1.5 tubing or the 4.5 casing. A sulfur smell can be detected in the vicinity of the well, but no H2S was noted on the gas detector. A ten foot diameter area, around the well, has been affected to the point that no vegetation is growing. The tank battery is comprised of one 210 barrel tank, a rusted out and collapsed 50 barrel steel tank and a production unit. No identification could be found at the wellhead or the tank battery. G-R Contracting Inc. shall submit a written plugging schedule to Eric Conrad at 5880 Memory Road Zanesville, Ohio 43701 within 15 days, per OAC 1501:9-11-05(B), and plug the well within 90 days. G-R Contracting Inc. will be notified if the plugging schedule is approved or denied.
0821050425 2016-10-12 Plug / Plug Back No Violations The purpose of my inspection today is to witness Appalachian Well Surveys run a bond log and shoot the 4.5 inch diameter casing off. During my inspection Appalachian logged the well and discovered we had free 4.5 inch casing to 4000 feet and the casing appears to be in good condition. Appalachian ran a casing cutter down to 4000 feet and shot the casing off. G-R contracting pulled two joints of the 4.5 inch casing.
0842877345 2016-08-08 Production Wells No Violations My inspection today finds the status of the well has not changed. The wellhead is badly deteriorated. The tubing has broken off. Valves on the 4.5 casing head have rusted off and the well is open to atmosphere. No repairs have been made to the well. I called and spoke to Jordan Jones with G-R Contracting and reminded him that a written plan of action is required for the well. Mr. Jones asked to be allowed to send the plan via email and I agreed.
1123035080 2016-09-14 Production Wells No Violations My inspection today finds the well owner has moved a dozer on location in preparation for plugging. Jordan Jones stated in a telephone conversation that the company intends to place one to two loads of brine in the well to quell any gas flow.
1420408808 2016-10-11 Plug / Plug Back No Violations The purpose of my inspection today is to witness Formations cementing set a plug within the Big Lime formation. During my inspection Appalachian Well Surveys shot the 1.5 inch diameter tubing off at 4525 feet. G-R Contracting pulled two joints of the 1.5 inch tubing and formations set a 300 foot Class A cement plug from 4525 to 4225 feet. G-R Contracting removed all of the 1.5 inch diameter tubing from the hole.
1475700745 2016-10-05 Plug / Plug Back No Violations The purpose of my inspection today is to witness Appalachian Well Surveys shoot the 1.5 inch diameter tubing at 5200 feet in order to get a proper bottom plug. During my inspection Appalachian ran in hole with their tools and they could only make it to 2800 feet. Appalachian pulled their tools back out of the hole and G-R Contraction ran a broach down hole to try and clear a column within the tubing 1.5 inch for Appalachians tools. Once G-R tripped back out of the hole Appalachian ran back in with their tools but could only get down to 3064 feet with this attempt. The depth we need to reach still has not been achieved. Appalachian tripped their tools back out of the hole. When the tools came to surface they attached a heavier sinker bar to the bottom of the casing cutter. Appalachian tripped back into the hole, got down 5194 feet, and successfully cut the 1.5 inch tubing. Appalachian tripped their tools back out of the hole. G-R rigged back up to the 1.5 inch diameter tubing to pull 2 joints up and the rig was not able to pull the tubing. Operations will resume tomorrow.
1680590625 2016-09-20 Production Wells No Violations My inspection today finds the well operator has dug around the wellhead to expose the 8.625 by 4.5 casing head with a back hoe. While digging the 4.5 by 1.5 tubing head fell off. Also, a G-R Contracting employee stated that his personal protection H2S monitor alarmed at 18 parts per million.
1855330907 2016-11-22 Final Restoration No Violations The purpose of my inspection today is a status check on a final restoration. During my inspection the location has been graded and seeded. Vegetation is growing on location and there is not any erosion issues. There is no evidence of an oil and gas well left behind. Location has met 1509.072 B requirements.
3476989 2002-8-5 0:00:0 PW No Violations
648290986 2016-10-13 0:00 PB No Violations 10.50
726455424 2016-7-19 0:00: TD No Violations 2.00
821050425 2016-10-12 0:00 PB No Violations 6.00
PL7660 PL No Violations

For data sources see[9]