X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-23299

Well Details

Well ID: 34-121-23299
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Jackson Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: SMITH
License Status: Producing
License Date: 1984-09-14
Spud Date: 1984-09-16
Spud Drilling Contractor: DYNAMIC DRILLING
Final Drill Date: 1984-09-22
Well Total Depth: 6216.00 ft
Configuration: Vertical
Latitude: 39.620000
Longitude: -81.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-09-14 Issued Date 9/14/84 Expired Date 3/13/85 Acres 0078000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06216 Proposed Drill Depth 06216
Original Spud 1984-09-16
Completed 1984-09-22
Reached Total Depth 1984-09-22
CO 1984-10-20 128 GREENLAND PETROLEUM CO GeoDate 9/14/84
Completion Report Received 1984-11-05
Construction Permit Expires 1985-03-13
CO 1991-11-13 1288 WATSON WAYNE W GeoDate 9/14/84
Change of Owner 2002-11-08 Operator changed from 1288, WATSON WAYNE W to 5935, DOVER ATWOOD CORP.
Change of Owner 2010-07-20 Operator changed from 5935, DOVER ATWOOD CORP. to 1634, NORTHWOOD ENERGY CORP
Last Compliance Report 2015-12-17
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5962 6048 0
5962 6048 0
2006-09-11 5984 6040 43
5984 6040 43
5962 6048 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 40000 FRAC: H2O,SAND,CO2
CO2 0 14 Tons 0 DUEL FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GREENLAND PETROLEUM CO 0.00 0.00 365
1985 GREENLAND PETROLEUM CO 6217.00 0.00 365
1986 GREENLAND PETROLEUM CO 3680.00 0.00 365
1987 GREENLAND PETROLEUM CO 4155.00 0.00 365
1988 GREENLAND PETROLEUM CO 6043.00 0.00 365
1989 GREENLAND PETROLEUM CO 4155.00 0.00 365
1990 GREENLAND PETROLEUM CO 2794.00 0.00 365
1991 GREENLAND PETROLEUM CO 29.00 0.00 365
1992 WATSON WAYNE W 1992.00 0.00 365
1993 WATSON WAYNE W 2381.00 0.00 365
1994 WATSON WAYNE W 1756.00 0.00 365
1995 WATSON WAYNE W 1377.00 0.00 365
1996 WATSON WAYNE W 1653.00 0.00 365
1998 WATSON WAYNE W 1327.00 0.00 365
1999 WATSON WAYNE W 733.00 0.00 365
2000 WATSON WAYNE W 787.00 0.00 365
2001 WATSON WAYNE W 601.00 0.00 365
2002 DOVER ATWOOD CORP. 644.00 0.00 365
2003 DOVER ATWOOD CORP. 1118.00 0.00 365
2004 DOVER ATWOOD CORP. 878.00 22.00 365
2005 DOVER ATWOOD CORP. 1250.00 0.00 365
2006 DOVER ATWOOD CORP. 1352.00 0.00 365
2007 DOVER ATWOOD CORP. 918.00 0.00 365
2008 DOVER ATWOOD CORP. 479.00 0.00 365
2009 DOVER ATWOOD CORP. 331.00 0.00 365
2010 NORTHWOOD ENERGY CORP 138.00 0.00 365
2011 DOVER ATWOOD CORP. 0.00 0.00 365
2012 NORTHWOOD ENERGY CORP 133.00 0.00 366
2013 NORTHWOOD ENERGY CORP 461.00 0.00 365
2014 NORTHWOOD ENERGY CORP 550.00 0.00 365
2015 NORTHWOOD ENERGY CORP 445.00 15.00 365
2016 NORTHWOOD ENERGY CORP 950.00 0.00 365
2017 NORTHWOOD ENERGY CORP 695.00 0.00 365
2018 NORTHWOOD ENERGY CORP 613.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GREENLAND PETROLEUM CO Brine 0 365
1985 GREENLAND PETROLEUM CO Brine 225 365
1986 GREENLAND PETROLEUM CO Brine 240 365
1987 GREENLAND PETROLEUM CO Brine 300 365
1988 GREENLAND PETROLEUM CO Brine 30 365
1989 GREENLAND PETROLEUM CO Brine 155 365
1990 GREENLAND PETROLEUM CO Brine 30 365
1991 GREENLAND PETROLEUM CO Brine 0 365
1992 WATSON WAYNE W Brine 0 365
1993 WATSON WAYNE W Brine 0 365
1994 WATSON WAYNE W Brine 0 365
1995 WATSON WAYNE W Brine 0 365
1996 WATSON WAYNE W Brine 0 365
1998 WATSON WAYNE W Brine 0 365
1999 WATSON WAYNE W Brine 0 365
2000 WATSON WAYNE W Brine 0 365
2001 WATSON WAYNE W Brine 0 365
2002 WATSON WAYNE W Brine 0 312
2003 DOVER ATWOOD CORP. Brine 52 365
2004 DOVER ATWOOD CORP. Brine 28 365
2005 DOVER ATWOOD CORP. Brine 0 365
2006 DOVER ATWOOD CORP. Brine 0 365
2007 DOVER ATWOOD CORP. Brine 0 365
2008 DOVER ATWOOD CORP. Brine 0 365
2009 DOVER ATWOOD CORP. Brine 0 365
2010 NORTHWOOD ENERGY CORP Brine 0 365
2011 NORTHWOOD ENERGY CORP Brine 0
2012 NORTHWOOD ENERGY CORP Brine 0 366
2013 NORTHWOOD ENERGY CORP Brine 0 365
2014 NORTHWOOD ENERGY CORP Brine 363 365
2015 NORTHWOOD ENERGY CORP Brine 166 365
2016 NORTHWOOD ENERGY CORP Brine 44 365
2017 NORTHWOOD ENERGY CORP Brine 39 365
2018 NORTHWOOD ENERGY CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1135779012 2012-3-21 0:00: AD No Violations
-53077681 2006-10-12 0:00 AD No Violations
0000PL7498 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0053077681 2006-10-12 Annular Disposal No Violations A.D.not hooked up well is equipped with pump jack and 1-100 bbl tank no violations noted at this time.
1135779012 2012-03-21 Annular Disposal No Violations Inspection of well found AD not hooked up or in use and the following equipment present 4.5 production casing, 1.5 tubing with the proper production valves open, 100 barrel tank and separator present in an established dike with proper well identification.
1504128222 2017-08-30 Temporary Abandoned Annular Disposal No Violations The purpose of my inspection was a status check on a temporarily abandoned annular disposal well. During my inspection the well was equipped with 8.625 inch diameter surface casing with a casing head, 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, rods, and a pumping unit. All production valves were in the open position. This well was not disposing brine through the annular disposal method. There was not an annular disposal connection plumbed up to the annulus. The production equipment consisted of one 100 barrel tank, one 50 barrel tank, one horizontal separator, and a meter run consisting of a 2 inch sales line, .25 inch orifice plate, and a chart meter dated 8/15/17. The identification was located on the 100 barrel tank.
PL7498 PL No Violations

For data sources see[9]

References