X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-23807

Well Details

Well ID: 34-121-23807
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Brookfield Township
Operator Name: D & D ENERGY COMPANY
Well Pad ID:
Farm/Lease Name: CENTRAL OHIO COAL CO
License Status: Producing
License Date: 1991-04-16
Spud Date: 1991-04-23
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1991-04-26
Well Total Depth: 5510.00 ft
Configuration: Vertical
Latitude: 39.800000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1991-04-16 1217 HARRISON ENERGY GeoDate 4/16/91
Oil and Gas 1991-04-16 Issued Date 4/16/91 Expired Date 4/15/92 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05510 Proposed Drill Depth 05510
Original Spud 1991-04-23
Completed 1991-04-26
Reached Total Depth 1991-04-26
Completion Report Received 1991-05-06
Construction Permit Expires 1992-04-15
Change of Owner 2004-01-27 Operator changed from 1217, HARRISON ENERGY to 5660, S & S ENERGY CORPORATION
Change of Owner 2015-06-02 Operator changed from 5660, S & S ENERGY CORPORATION to 5569, D & D ENERGY COMPANY
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5317 5324 8
2006-09-11 5347 5358 12
5317 5324 8
5317 5324 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 94000 Gal 60000
ACID 0 500 Gal 0 FRAC W/94M GAL H20,600 SX SAND, 31
N2 0 31 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 HARRISON ENERGY 13233.00 0.00 365
1997 HARRISON ENERGY 8965.00 0.00 365
1998 HARRISON ENERGY 5582.00 0.00 365
1999 HARRISON ENERGY 6112.00 0.00 365
2000 HARRISON ENERGY 2528.00 0.00 365
2003 S & S ENERGY CORP 324.00 0.00 365
2004 S & S ENERGY CORP 1963.00 0.00 365
2005 S & S ENERGY CORP 4840.00 0.00 365
2006 S & S ENERGY CORP 4086.00 0.00 365
2007 S & S ENERGY CORP 3312.00 0.00 365
2008 S & S ENERGY CORP 4189.00 0.00 365
2010 S & S ENERGY CORP 5056.00 0.00 365
2011 S & S ENERGY CORP 4707.00 0.00 365
2013 S & S ENERGY CORP 4278.00 0.00 365
2014 S & S ENERGY CORP 3048.00 0.00 365
2015 D & D ENERGY COMPANY 771.00 0.00 0
2016 D & D ENERGY COMPANY 0.00 0.00 0
2017 D & D ENERGY COMPANY 0.00 0.00 0
2018 D & D ENERGY COMPANY 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 HARRISON ENERGY Brine 0 365
1997 HARRISON ENERGY Brine 0 365
1998 HARRISON ENERGY Brine 0 365
1999 HARRISON ENERGY Brine 0 365
2000 HARRISON ENERGY Brine 0 365
2003 S & S ENERGY CORP Brine 0 365
2004 S & S ENERGY CORP Brine 96 365
2005 S & S ENERGY CORP Brine 115 365
2006 S & S ENERGY CORP Brine 41 365
2007 S & S ENERGY CORP Brine 70 365
2008 S & S ENERGY CORP Brine 131 365
2010 S & S ENERGY CORP Brine 116 365
2011 S & S ENERGY CORP Brine 75 365
2013 S & S ENERGY CORP Brine 74 365
2014 S & S ENERGY CORP Brine 80 365
2015 D & D ENERGY COMPANY Brine 0 0
2016 D & D ENERGY COMPANY Brine 0 0
2017 D & D ENERGY COMPANY Brine 0 0
2018 D & D ENERGY COMPANY Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2081908104 2015-10-29 0:00 PW No Violations 1.00
0000017846 Preliminary Restoration No Violations PASSED Y WITNESSED 10/7/92 INSPECTOR TED DOBBIN DATE 10/0719/92 DATA FROM OLD VAX INFO
17846 PL No Violations
2081908104 2015-10-29 Production Wells No Violations Upon inspection, it was observed that this well is capable of production, but is currently shut-in. The well consists of 12 conductor, 8.625 surface casing, 4.5 production casing, and 1.5 production tubing with a plunger lift system. The tank battery consists of a 100 bbl production tank, horizontal separator, drip, meter run, and containment dike. Legible ID is posted at the well and on the production tank, however the permit number posted is incorrect. The lease road is in good condition and is stabilized with vegetation. The status of the well in RBDMS is PR.

For data sources see[9]

References