If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-23995 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.65,"lon":-81.47,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Jefferson Township | |
Operator Name: FQ ENERGY SERVICES LLC | |
Well Pad ID: | |
Farm/Lease Name: WARREN DRILLING CO (SWIW #6) | |
License Status: Active Injection | |
License Date: 2008-08-11 | |
Spud Date: 2001-10-15 | |
Spud Drilling Contractor: WARREN DRLG | |
Final Drill Date: 2001-10-21 | |
Well Total Depth: 6075.00 ft | |
Configuration: Vertical | |
Latitude: 39.650000 | |
Longitude: -81.470000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2001-08-09 | Proposed Formations:ONONDAGA/CLINTON/MEDINA, Issued Date:8/9/2001, Expired Date:8/9/2002 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2001-08-24 | CHANGE IN CIVIL TOWNSHIP TO JACKSON. |
Original Spud | 2001-10-15 | RBDMS Rec |
Completed | 2001-10-21 | RBDMS Rec |
Reached Total Depth | 2001-10-21 | RBDMS Rec |
Completion Report Received | 2002-08-01 | RBDMS Rec |
Annulus Pressure Monitoring Approved | 2008-08-11 | RBDMS Rec |
APP | 2008-08-11 | Proposed Formations:CLINTON/MEDINA, Issued Date:8/11/2008, Expired Date:8/11/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2008-08-11 | RBDMS Rec |
First Injection | 2008-09-26 | RBDMS Rec |
Construction Permit Expires | 2009-08-11 | RBDMS Rec |
Change of Owner | 2010-03-24 | Operator changed from 2348, TRIAD RESOURCES INC to 8611, HUNTER DISPOSAL LLC |
Change of Owner | 2016-05-20 | Operator changed from 8611, HUNTER DISPOSAL LLC to 9679, FQ ENERGY SERVICES LLC |
Record Last Modified | 2016-05-20 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2002-08-29 | 5764 | 5782 | 72 |
2002-08-29 | 5882 | 5892 | 40 |
5764 | 5782 | 72 | |
5882 | 5892 | 40 | |
5764 | 5782 | 72 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 92000 Gal | 46000 | 600 GALLONS HCL ACID | ||
H2O | 15 | 15000 Gal | 30000 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | TRIAD RESOURCES INC | 0.00 | 0.00 | 365 |
2002 | TRIAD RESOURCES INC | 0.00 | 0.00 | 365 |
2003 | TRIAD RESOURCES INC | 22992.00 | 247.00 | 365 |
2004 | TRIAD RESOURCES INC | 16054.00 | 94.00 | 365 |
2005 | TRIAD RESOURCES INC | 5022.00 | 27.00 | 365 |
2006 | TRIAD RESOURCES INC | 0.00 | 24.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2002 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2003 | TRIAD RESOURCES INC | Brine | 750 | 365 |
2004 | TRIAD RESOURCES INC | Brine | 0 | 365 |
2005 | TRIAD RESOURCES INC | Brine | 435 | 365 |
2006 | TRIAD RESOURCES INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1010353906 | 2012-9-18 0:00: | SW | No Violations | |
-1039961252 | 2017-5-14 0:00: | SW | No Violations | |
-1067095854 | 2011-2-7 0:00:0 | SW | No Violations | |
-1130612799 | 2017-10-17 0:00 | SW | No Violations | |
-1142103600 | 2015-10-1 0:00: | SW | No Violations | |
-1151411208 | 2018-6-8 0:00:0 | SW | No Violations | |
-1154905397 | 2009-3-4 0:00:0 | SW | No Violations | |
-11607477 | 2019-6-17 0:00: | SW | No Violations | |
-1170446904 | 2019-1-28 0:00: | SW | No Violations | |
-1174701335 | 2012-11-28 0:00 | SW | No Violations | |
-1179335372 | 2017-11-13 0:00 | SW | No Violations | |
-1207000141 | 2010-5-19 0:00: | SW | No Violations | |
-1233527775 | 2013-1-30 0:00: | SW | No Violations | |
-1341445703 | 2017-6-12 0:00: | SW | No Violations | |
-1353190046 | 2020-8-20 0:00: | SW | No Violations | |
-1367839989 | 2010-3-1 0:00:0 | SW | No Violations | 1.00 |
-1418890895 | 2012-1-20 0:00: | SW | No Violations | |
-1477032340 | 2013-1-16 0:00: | SW | No Violations | |
-1492534071 | 2019-8-1 0:00:0 | SW | No Violations | |
-1502004210 | 2015-5-28 0:00: | SW | No Violations | |
-1538136065 | 2010-5-24 0:00: | SW | No Violations | |
-1575556100 | 2010-4-13 0:00: | SW | No Violations | 1.00 |
-1591808433 | 2015-4-7 0:00:0 | SW | No Violations | |
-1607557888 | 2012-1-26 0:00: | SW | No Violations | |
-16530251 | 2013-4-10 0:00: | SW | No Violations | 2.00 |
-1653160281 | 2017-8-24 0:00: | SW | No Violations | |
-1670994569 | 2014-7-8 0:00:0 | SW | No Violations | |
-168827663 | 2016-6-7 0:00:0 | SW | No Violations | |
-1748487897 | 2012-1-5 0:00:0 | SW | No Violations | |
-1764069429 | 2016-9-29 0:00: | SW | No Violations | |
-1825222284 | 2016-5-18 0:00: | SW | No Violations | |
-1826208093 | 2013-10-16 0:00 | SW | No Violations | |
-1851417664 | 2015-12-16 0:00 | SW | No Violations | |
-1862396247 | 2018-5-31 0:00: | SW | No Violations | |
-1884873517 | 2016-3-18 0:00: | SW | No Violations | |
-1891307927 | 2011-3-15 0:00: | SW | No Violations | |
-1897140332 | 2017-9-7 0:00:0 | SW | No Violations | |
-1946856636 | 2020-6-17 0:00: | SW | No Violations | |
-1948211525 | 2011-12-19 0:00 | SW | No Violations | |
-1953711070 | 2016-2-3 0:00:0 | SW | No Violations | |
-1958707235 | 2016-5-31 0:00: | SW | No Violations | |
-1966013636 | 2015-2-5 0:00:0 | SW | No Violations | |
-2101059174 | 2015-8-13 0:00: | SW | No Violations | |
-2102968699 | 2017-1-11 0:00: | SW | No Violations | |
-2133566655 | 2014-4-23 0:00: | SW | No Violations | |
-337548586 | 2018-5-11 0:00: | SW | No Violations | |
-342304102 | 2019-3-19 0:00: | SW | No Violations | |
-361736519 | 2012-1-23 0:00: | SW | No Violations | |
-362983007 | 2010-7-20 0:00: | SW | No Violations | |
-410383361 | 2012-1-30 0:00: | SW | No Violations | |
-415386596 | 2009-12-28 0:00 | SW | No Violations | |
-43160841 | 2018-4-6 0:00:0 | SW | No Violations | |
-436628049 | 2018-3-9 0:00:0 | SW | No Violations | |
-453832949 | 2011-6-20 0:00: | SW | No Violations | |
-487316344 | 2014-4-11 0:00: | SW | No Violations | |
-498762838 | 2011-8-30 0:00: | SW | No Violations | |
-521316899 | 2018-11-28 0:00 | SW | No Violations | |
-522460586 | 2016-3-2 0:00:0 | SW | No Violations | |
-596616002 | 2014-6-3 0:00:0 | SW | No Violations | |
-634337737 | 2009-10-27 0:00 | SW | No Violations | |
-689806912 | 2020-2-4 0:00:0 | SW | No Violations | |
-710280961 | 2010-9-9 0:00:0 | SW | No Violations | |
-711904290 | 2011-2-22 0:00: | SW | No Violations | |
-769349426 | 2016-8-16 0:00: | SW | No Violations | |
-799488934 | 2012-10-30 0:00 | SW | No Violations | |
-832384800 | 2018-1-25 0:00: | SW | No Violations | |
-845411039 | 2018-11-5 0:00: | SW | No Violations | |
-915066175 | 2013-6-4 0:00:0 | SW | No Violations | |
-92346585 | 2013-9-19 0:00: | SW | No Violations | |
-965290152 | 2016-3-16 0:00: | SW | No Violations | |
-985735474 | 2016-10-25 0:00 | SW | No Violations | |
-987482248 | 2017-8-15 0:00: | SW | No Violations | |
0016530251 | 2013-04-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection .
Note: Talked to Rick Zigenfoose concerning restoring pipeline rightaway which they disturbed when they installed new flow line to well during the winter months. |
0043160841 | 2018-04-06 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection .
|
0074062113 | 2015-02-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that there was several company owned vacuum trucks waiting to unloading at the facility during my inspection. |
0092346585 | 2013-09-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that unloading pad is in need of repair it has encountered cracks in concrete and they will need to be repaired ASAP to prevent any seepage from pad from entering fresh water strata. |
0105797727 | 2017-07-26 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection. |
0144038833 | 2014-10-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that three company vacuum trucks were unloading at the facility during my inspection. |
0168827663 | 2016-06-07 | Salt Water Injection Well | No Violations | Inspection revealed that company reps were plumbing up tubing to flow line so they can place well back into operation once packer setting depth variance is approved by the divisions UIC section supervisor. |
0191109629 | 2008-12-04 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation during my inspection, well caretaker was changing filter in filter house during my inspection.
Note:three Key Energy trucks were unloading at site during my inspection and one company owned truck was waiting to be unloaded discussed with caretaker future plans on getting stone placed on road to unloading site to help on tracking mud out onto state route 821. |
0194840039 | 2018-08-15 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during or truck audit session, it was noted that only two company owned tankers were offloading at the facility during our time on site. |
0196108491 | 2016-08-25 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation and workers continue to work on raising dike height too resolve compliance notice issued at a earlier date. |
0256642301 | 2009-08-14 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation, injection pump was running during my inspection.
Note: 1/4 valve on tubing is in need of replacement and driveway needs to be graded and stone applied to help minimize tracking mud etc.. Out onto state highway. |
0273405765 | 2011-05-19 | Salt Water Injection Well | No Violations | On site with Tom Tomastik to inspect well site.
Note: Driveway needs more stone and access road to wellhead needs to be maintained. |
0280413014 | 2012-10-23 | Salt Water Injection Well | No Violations |
Inspection revealed that injection pump was in operation during my inspection and it was noted that company owned vacuum trucks were unloading at facility during my inspection. Note: Took water sample from pump house and took to lab to be analyzed. |
0287621448 | 2016-10-13 | Salt Water Injection Well | No Violations | Injection pump was in operation during my inspection. |
0337548586 | 2018-05-11 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection and it was noted that one AOS vacuum truck was on site offloading during my inspection.
Note: Walked flowline area to monitor area for potential leaks . |
0342304102 | 2019-03-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
0352117884 | 2016-05-21 | Salt Water Injection Well | No Violations | On site to witness rig crew release packer and pull it from well, had them line entire site with pit liner to prevent any oil base fluids from hitting the ground in the event of a uncontrollable flow in well they had to load hole on two occasions to keep well on vacuum and it was determined that tubing had seven hole in it just above the packer assembly.
Note: They will start new tubing and packer in well on Monday morning. |
0361736519 | 2012-01-23 | Salt Water Injection Well | No Violations | On site to witness the operator try and move packer. Setting depth of packer is 5684. They were unable to move it today due to downhole conditions. They will attempt to release and reset packer tomorrow. Zero pressure was left on the annulus today and they will check pressure tomorrow to determine if packer is leaking, |
0362983007 | 2010-07-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection, noted that seals on transfer pump is in need of replacement and pump house is in need of a good cleaning. |
0383651968 | 2008-09-17 | Salt Water Injection Well | No Violations | On site to witness operator run Packer&new 2.875 into well,Baker Set Lock type packer with down hole shut off valve overall BHA is 20.50 longtotal tubing in hole is 5760.15 packer setting depth is 5743,tested annulus of tubing@1680 psi and monitored pressure for 15 min with no decline in pressure blee pressure on annulus to 500 psi and left well shut in awaiting foe acid job to be preformed and testing of flow line at later date before placing well into operation. |
0399130625 | 2010-11-03 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and pump was in operation during my inspection, noted that new pump house is nearly completed and once completed they will move pumps to new facility and place them into operation. |
0410383361 | 2012-01-30 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform acid job on said well they pumped 500 gal of 20% and 1500 gal of 15% acid into well and displaced it into formations and let soak for 30 min and then proceeded to displace into formation at a rate of 1.2 bpm with 50 bbl of fresh water pressure was noted@1300 psi and after shutting well in it was noted @1080 psi then job was complete and Producers rigged down equipment and well was placed back into operation. |
0415386596 | 2009-12-28 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and pump was running during my inspection.
Note: All storage tanks have been cleaned out and sludge hauled to approved site, need stone on driveway to unloading pad. |
0425883466 | 2019-05-06 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection, owner voluntarily shut injection operations down for 24 hour period so formation pressures in a adjacent well would allow for plugging operations. |
0430056563 | 2017-12-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
0436628049 | 2018-03-09 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection. |
0453832949 | 2011-06-20 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation during my inspection it was noted that 2 valve on wellhead needs to be replaced and restoration work around facility needs to be finished in the near future. |
0478374554 | 2008-11-04 | Salt Water Injection Well | No Violations | No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Proper signage is required at location by the road and stone is needed on lane going too said well. |
0487316344 | 2014-04-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that several company owned vacuum trucks were waiting to unload at facility during my inspection. |
0498762838 | 2011-08-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that pump is in need of having packing replaced on pump and several leaks on plumbing was pointed out to operator that needs to be fixed ASAP. |
0503432940 | 2004-01-02 | Production Wells | No Violations | No violations noted,rabbit well location will need to be seeded &mulched when work is completed on disposal well next too this existing well. |
0521316899 | 2018-11-28 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection.
Note: Two company owned vacuum trucks were on site during my inspection. |
0522460586 | 2016-03-02 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED 3/8/2016. |
0524226825 | 2011-04-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today.
Note: Stone is needed on driveway to unloading facility to help cut down on tracking mud onto state highway and also restoration work around new pump house and surrounding area needs to be completed as soon as weather permits. |
0530109804 | 2015-01-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that three company owned vacuum trucks were unloading at the facility on this day of my inspection. |
0536961246 | 2016-07-21 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump too this well was in operation during my inspection.
Note: One 25-463 vacuum truck was unloading at the facility today, also operator has removed four of there storage tanks from containment area and they are currently in process of having stone removed from area to allow for volumes needed to become into compliance with SPCC rules. |
0554229073 | 2013-12-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation and it was noted that four company owned vacuum trucks were unloading at facility during my inspection. |
0564011652 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION ON FEBRUARY 26, 2018 |
0596616002 | 2014-06-03 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that several company owned vacuum trucks were unloading at facility during my inspection. |
0634337737 | 2009-10-27 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump is in operation it was running during my inspection, noted a small seep on injection pump will inquire about it with operator and have him repair.
Note: More stone is needed on drive going to unloading pad it will help cut down on tracking mud onto highway and reduce risk of causing potential hazard at site. |
0654179569 | 2019-04-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were not in operation during my inspection. |
0656479452 | 2019-05-03 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection and attendant stated that they had just shut pump down prior to my inspection. |
0697443642 | 2011-01-14 | Salt Water Injection Well | No Violations | On site to witness testing of new poly flow line they pressured up line to 300 psi and waited required interval and then applied more pressure to line and again waited required interval, once we acquired 1800 psi we monitored pressure for 15 min with no decline in pressure. |
0699493546 | 2018-01-04 | Salt Water Injection Well | No Violations | Inspection revealed that operator had just started injection pump too this well just prior to my arrival or inspection.
Walked flowline right away to monitor area for any potential leaks none were detected and it was noted that three company owned tankers were offloading at the facility during my inspection. |
0700037772 | 2009-04-28 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation, injection pump was in operation noted two Key Energy trucks unloading at site during my inspection and also there was a crew applying seed&mulch to area around pump house. |
0710280961 | 2010-09-09 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and upgrades at facility are progressing, new tanks have been installed and a new pump house is being built and new poly flow injection line will be put into place in the near future. |
0711904290 | 2011-02-22 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation today,talked to well tender and he stated they have brine haulers coming to site later today to unload. |
0769349426 | 2016-08-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation and it was noted that operator is letting used filters begin to build up within the pump house. |
0799488934 | 2012-10-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and there were several company owned vacuum trucks unloading at facility during my inspection. |
0832384800 | 2018-01-25 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation today and it was noted that two company owned vacuum trucks were offloading at the facility today. |
0835876322 | 2009-01-05 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation.
Note: Pump was not in operation during my inspection, noted that stone is needed on road to unloading pad to help minimize tracking mud out onto state highway when brine trucks are leaving facility. |
0845411039 | 2018-11-05 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that one company owned tanker was on site offloading during my inspection. |
0851438863 | 2019-03-07 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were in operation and it was noted that one company owned tanker was offloading at the facility during my inspection. |
0860190599 | 2014-11-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that one Hall Drilling vacuum truck was unloading and one company owned vacuum truck was on the unloading pad during my inspection and it was noted that one of the storage tanks is being cleaned out so owner can replace valves on the bottom of the storage tank. |
0915066175 | 2013-06-04 | Salt Water Injection Well | No Violations | Injection pump was in operation today and it was noted that two company owned vacuum trucks were unloading at facility during my inspection. |
0943459927 | 2017-03-23 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation and it was noted that one company owned truck was unloading at the facility during my inspection. |
0963030536 | 2016-04-12 | Salt Water Injection Well | No Violations | Well is down waiting on approval to repair said well. |
0965290152 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED |
0981890097 | 2019-04-12 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection. |
0985735474 | 2016-10-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation and it was noted that one company owned was unloading at the facility today. |
0987164803 | 2016-11-08 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump to this well was not in operation and it was noted that dike work at the facility has been completed and is in compliance with prior compliance notice issued. |
0987482248 | 2017-08-15 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were in operation during my inspection.
Note: Two company owned vacuum trucks were unloading at the facility during my inspection. |
0998063299 | 2018-07-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
|
1007606664 | 2010-01-20 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation during my inspection, noted two Key Energy tankers unloading at facility.
Note: Swabs on center piston in need of replacement and stone is needed on road to unloading pad. |
1010353906 | 2012-09-18 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that fluid end of pump is in need of replacement it sounds like it has internal problems and needs to be addressed. |
1039961252 | 2017-05-14 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump to this well was in operation during my inspection and it was noted that two Myers vacuum trucks were unloading at the facility during my inspection. |
105797727 | 2017-7-26 0:00: | SW | No Violations | |
1067095854 | 2011-02-07 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump is in operation and it was noted that several vac trucks were at site today unloading brine water. |
1071135733 | 2014-04-23 | Salt Water Injection Well | No Violations | On the day of my inspection I accompanied Dave Ball. Pressure was 480 lb and the pump was running. No violations noted. |
1093786476 | 2004-08-25 | Preliminary Restoration | No Violations | Restoration satisfactory, pits have been filled and location restored and vegatation established.
Rabbit well 1-100bbl located within dike area. |
110024123 | 2019-12-5 0:00: | SW | No Violations | |
1102406188 | 2019-7-15 0:00: | SW | No Violations | |
1130612799 | 2017-10-17 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation when I arrived on site prior to acid treatment job, Baker Hughes performed 800 gallon of 28% HCL acid treatment on said well during my inspection. |
1135757786 | 2013-02-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and well attendant stated that they were not receiving much water at this time due to weather conditions. |
1142103600 | 2015-10-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that several company owned vacuum trucks were waiting to unload at the facility. |
1151411208 | 2018-06-08 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform 1500 gallon acid treatment on said well. |
1154905397 | 2009-03-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection, noted Key Energy truck unloading at site during my inspection, noted that #2 cylinder piston was dripping a little will notify well owner and discuss pump repair is needed. |
1170446904 | 2019-01-28 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that one company owned tanker was offloading at the site during my inspection. |
1171616172 | 2010-07-13 | Salt Water Injection Well | No Violations | On site to witness placing of liner in new proposed water tank storage area,area covered was approximately 125 wide X 100 long and stone was placed on it by slinger truck and dike walls are too be covered also after applying adhesive then stone on top of that.
Note: Liner was 30 mil black plastic. |
1174701335 | 2012-11-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that several vacuum trucks were waiting to unload at facility .
Note: Walked flow line area to monitor area for potential leaks none were found today. |
1179335372 | 2017-11-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Noted two company owned tankers unloading at the facility during my inspection. |
1207000141 | 2010-05-19 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation and injection pump was running during my inspection, on site to witness clean up of brine&oil within dike area(tanks ran over) all spillage was contained within dike area and all brine and oil was cleaned up and properly disposed of, instructed well tender to apply a few absorbent pads to area in case any oil became present at site. |
1207988991 | 2016-05-26 | Salt Water Injection Well | No Violations | On site to witness MIT test they attempted to set packer@5737 test failed then they reset packer@5706 failed again then decision was made to pull up to 5565 which was 10 above where packer was previously set and it tested fine they applied 1800 psi and we monitored pressure for 15 minutes with a 10 psi loss in pressure (TEST PASSED). |
1211408293 | 2008-05-21 | Production Wells | No Violations | Site evaluation for converting to SWIW Permit, inspection revealed existing flow line to permit #4037 located approximately 40 to south of wellhead and wet weather run located approximately 150 to west and small water way 300 to north of well no water wells located within 1000 of site that could be located, remind applicant that road to wellhead will need o be constructed and properly maintained. |
1222529978 | 2008-09-24 | Salt Water Injection Well | No Violations | On site to witness Producers Service Corp. spot 1000 gal acid into well bore and pressure test flow line from pump house to wellhead, filled line with H2O and pressured tested 2 plastic coated line pipe to 1680 psi and monitored weld seams for 15 min no leaks detected released pressure and then proceeded to place well into operation. |
1223001252 | 2012-04-17 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that 2 union on plumbing on discharge side of pump is in need of replacement, well tender stated he would shut pump down and repair leaking union and it was also noted that filter transfer pump is in need of seal replacement and well tender stated that they had one ordered. |
1223422674 | 2008-10-07 | Salt Water Injection Well | No Violations | Operator called and requested that I be present to witness them reapply pressure to annulus of tubing, line to recorder failed and they lost pressure on annulus so they wanted to have pressure reapplied and wanted Inspector present to witness the job being preformed they had Timcos solvent pressure up on annulus with 4 gal H2O with inhibitor added. |
1233527775 | 2013-01-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and several owned vacuum trucks were at site during my inspection. |
1258582921 | 2009-11-17 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection,noted that pistons on pump had been recently changed. |
1266442843 | 2010-02-17 | Salt Water Injection Well | No Violations | On site towitness operator remove bad storage tank and replace with 2-500 bbl storage tanks and replumb and test plumbing for leakage (non noted).
Note:Five Centralas tankers were unloading at facility and two RET vac trucks and 2 EC tankers were at site during my inspection. |
1272710821 | 2010-04-29 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation, noted that injection pump had been changed out since my last inspection, new pump is equipped with five cylinders instead of conventional triplex style. |
1276554357 | 2010-06-11 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation injection pump was running during inspection.
Note: Both tranfer pumps inside pump house are in need of repair(seals are out on both pumps). |
1281490269 | 2010-08-10 | Salt Water Injection Well | No Violations | On site to witness acid job being preformed on injection well, Producers Services pumped 2000 gal of 15%acid down well at a rate of 1.4 bpm at average pressure of 1550 psi and displaced with 100 gal water then injection pump was placed back in operation and it appeared that injection pressure was still declining after injection pump was started up will check back tomorrow and recheck pressures at wellhead. |
1289040952 | 2010-11-05 | Salt Water Injection Well | No Violations | Inspection revealed that Producers Services were on site performing acid treatment on well they pumped 2000 gal. of 15%acid at a rate of 1.1 bpm and pumped 1700 gal then we shut down and let acid soak for 15 min and then we pumped additional 300 gal and displaced into formation and shut well in too let acid soak they will resume operations later today. |
1294264730 | 2011-01-04 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation during my inspection.
Note: On site to witness owner apply sealant to exterior of dike liner and place stone on it with stone slinger truck they applied seven tandem loads of stone to liner. |
1323645171 | 2016-01-06 | Salt Water Injection Well | No Violations | Down for repair they are currently flowing well back hoping the well will go static soon. |
1323898655 | 2011-12-14 | Salt Water Injection Well | No Violations | Inspection revealed that well was shut down to perform 2000 gallon acid treatment. Producers Services preformed work and flushed tubing. Hunter Disposal personnel hooked well back up and placed the well back into operation. |
1326846835 | 2012-01-17 | Salt Water Injection Well | No Violations | On site to witness the Boots&Coots snubbing unit run 2.875 tubing into the well to retrieve the faulty packer. They had to wash the tool onto the top of the packer. The Baker Tool representative then released the packer and they let the element relax for 30 minutes. They then started too pull the packer. |
1326934377 | 2012-01-18 | Salt Water Injection Well | No Violations | On site to witness new packer and tubing run into well. The rig stopped 60 off of setting depth today. They will set the packer tomorrow, then flush annulus and test ithe integrity of casing and tubing. |
1327740337 | 2012-01-27 | Salt Water Injection Well | No Violations | Onsite to witness setting of packer and testing of tubing annulus. Producers Service pumped 70 barrels water, with inhibitor, down tubing and up backside. Once they had clean fluids at the surface the tubing was reattached to the packer, the packer was set at @ 5575 and testing began. They pressured up to 1830 PSI and they monitored the pressure for 15 min with a 30 PSI decline - test passed. They then pumped 50 barrels down tubing to ensure that they were pumping into formations. They will start rigging down tomorrow and perform an acid job on Monday. I informed the well owner that a variance would need to be applied for since we had to move packer up hole to achieve proper testing. |
1328658135 | 2012-02-02 | Salt Water Injection Well | No Violations | Well is in operation stopped to check pressures due to fact of recent tubing change in well.
Note: Instructed site foreman to work on getting small leaks in pump house addressed before they become major problems. |
1336312850 | 2012-05-03 | Salt Water Injection Well | No Violations | Inspection revealed that pump was in operation today and several vacuum trucks were unloading during my inspection. |
1341445703 | 2017-06-12 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump to this well not was in operation during my inspection.
Note: Walked area of buried flowline flowline from pumphouse to wellhead and found no signs of leakage. |
1343949401 | 2012-08-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection, it was noted that pump has several leaks that need to be addressed and it was also noted that filter housing and transfer pump is in need of replacement. |
1367839989 | 2010-03-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection,noted B&D Oil Gathering tanker unloading at facility during my inspection.
Note: Stone has been applied to drive going to unloading pad since my last inspection. |
1373829259 | 2018-03-01 | Salt Water Injection Well | Violations Noted | The Division received annual report form 204. Review of the form 204 revealed an exceedance of the maximum allowable injection pressure. The injection pressure shall be reduced and the auto shut down switch shall be adjusted to the maximum allowable injection pressure. A follow-up inspection will be conducted. |
1375898120 | 2013-08-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that storage tanks are being cleaned out this week ad solids are being solidified and hauled to a approved landfill. |
1385497600 | 2013-11-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and operator stated that storage tanks were nearly empty and they were not expecting very many trucks today due to weather conditions. |
1405381784 | 2014-07-14 | Salt Water Injection Well | No Violations | On site to witness 2000 gallon acid treatment on well Producers Services pumped acid and displaced it with brine water and they let it soak for one hour before placing well back into operation. |
1405552035 | 2014-07-14 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform 2000 gal acid treatment on said well. |
1418890895 | 2012-01-20 | Salt Water Injection Well | No Violations | I received a call from the well operator that the pressure has risen on the tubing annulus. The packer was set, tested and passed on 1/19/2012. The pressure rose on the tubing annulus overnight and the decision was made to attempt to move packer uphole 4 and reset the packer. They will then test the packer and monitor pressures for an extended period of time to ensure that it is in proper working order. |
1426880460 | 2015-03-20 | Salt Water Injection Well | No Violations | Producers Services on site to perform 2000 acid treatment on said well they pumped 1000 gallon of acid and displaced it into formation and let soak for one hour and then pumped remaining 1000 gallon and displaced it into formation again and let soak for one additional hour before placing well back into operation. |
1435006225 | 2015-06-17 | Salt Water Injection Well | No Violations | Inspection revealed that owner has replaced old flow line with new 3 fiber spar line and we pressure tested line at 1730 psi and monitored pressures for 20 minutes with no decline in pressure(TEST PASSED). |
144038833 | 2014-10-24 0:00 | SW | No Violations | |
1463432525 | 2016-05-13 | Salt Water Injection Well | No Violations | Inspection today revealed that Baker wireline was on site to attempt to get tools down inside of tubing to check total depth on tubing but after several attempts decision was made to cancel job for today.
Note: Tools sat down at 200 suspect scale buildup on inside of tubing. |
1463934450 | 2016-05-19 | Salt Water Injection Well | No Violations | On site to witness Deep Well Services attempt to kill well with 12# brine they were unsuccessful and decision was made to bring in 14# drilling fluid to kill well and release packer and pull it from wellbore. |
1464121885 | 2016-05-23 | Salt Water Injection Well | No Violations | Inspection today revealed that Deepwell Services snubbing unit was running casing scrapper and bit in hole and they sat down in the area above Medina Sand and decision was made to come out of hole and remove scrapper and go back in hole with bit and clean out to a depth below the Medina and then they will run tubing and packer in the near future. |
1464363958 | 2016-05-25 | Salt Water Injection Well | No Violations | On site to witness Deepwell Energy Services start Baker Hughes packer in well. |
1465937339 | 2016-06-14 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection and it was noted that three Myers tankers were unloading at the facility during my inspection. |
1468069377 | 2012-01-04 | Salt Water Injection Well | No Violations | Received call from well operator of said well is showing sign of equalizing pressures told them to shut well down and get service rig on site ASAP to correct problem they stated that rig would be there this afternoon and would be ready to test tubing in morning for possible hole in tubing if not they will pull tubing and packer too find problem. |
1470435121 | 2016-08-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection and it was noted that one Myers tanker was unloading at the facility during my inspection. |
1472737664 | 2016-08-29 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation and workers were working on getting dike height raised to get containment area into compliance with SPCC rules. |
1477032340 | 2013-01-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and tank area was clean and in near future owner will need to perform cleaning of unloading pad.
Note: Curb in front of garage door opening is in need of replacement. |
1478070199 | 2009-02-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection,as noted from last inspection stone is needed on drive to unloading pad vac trucks are tracking mud onto state highway as they exit facility.
Note: B&D oil was unloading brine at facility during my inspection. |
1480608141 | 2016-11-30 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were not in operation at the facility today. |
1486812372 | 2017-02-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one company owned vacuum truck was unloading at the facility during my inspection. |
1495745161 | 2017-05-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump to this well was not in operation during my inspection. |
1501482347 | 2016-12-13 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection. |
1502004210 | 2015-05-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and in conversation with operator stating that they were planning on replacing current injection pump in the near future. |
1509426759 | 2016-05-20 | Salt Water Injection Well | No Violations | On site to witness Deep well Services pump 14# drilling fluid down well to kill flow and to monitor site for any potential environmental concerns in the event of a uncontrolled flow.
Note: Well is dead and rig crew started to rig up snubbing unit to prepare and pull packer and tubing tomorrow. |
1514006239 | 2020-3-13 0:00: | SW | No Violations | |
1520279932 | 2018-03-04 | Salt Water Injection Well | No Violations | Follow up inspection revealed that on the day of my inspection injection pump was not in operation and I requested that we test murphy switch to insure that it was working properly they started pump and we monitored pressure until it reached 1675 psi and pump shut down which is 5 psi below maximum allowable pressure at present time switch appears to be working properly. |
1528814808 | 2019-8-23 0:00: | SW | No Violations | |
1529694304 | 2018-06-22 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation and it was noted that one company owned vacuum truck was offloading at the facility during my inspection. |
1533484834 | 2018-08-01 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation and it was noted that one company owned tanker was on site offloading during my inspection. |
1538136065 | 2010-05-24 | Salt Water Injection Well | No Violations | Stopped by well site too check and see if recent acid job on well helped injection pressure it was noted that current pressure was at lowest point it has been in quite some time. |
1538424388 | 2018-10-01 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that two company owned tankers were offloading during my inspection. |
1550157510 | 2012-06-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: New fluid end on injection pump since my last inspection. |
1561092856 | 2010-05-20 | Salt Water Injection Well | No Violations | On site to witness Producers services preformed acid job on injection well they placed 1000 gal of 15% acid in well and displaced with fresh water into injection zone and shut well in, operator will resume operations 5/21/2010. |
1562338686 | 2019-7-2 0:00:0 | SW | No Violations | |
1572627710 | 2019-10-29 0:00 | SW | No Violations | |
1575556100 | 2010-04-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: Gear end on injection pump showing signs of bearing failure, talked to well tender and he stated that they were planning on changing out pump tomorrow. |
1577465112 | 2014-01-03 | Salt Water Injection Well | No Violations | On site along with Producers Services to perform 2000 gallon acid job on said well. |
1591662479 | 2013-02-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and facility is in satisfactory condition this inspection. |
1591808433 | 2015-04-07 | Salt Water Injection Well | No Violations | Inspection on this indicated that injection pump was in operation and it was noted that several company owned vacuum and tanker trucks were waiting to unload at the facility during my inspection. |
1600549545 | 2008-09-04 | Salt Water Injection Well | No Violations | On site to witnees operator attempt to retrive lost tools in hole they ran 2.375 tubing in hole with overshot and bumper sub&hydrolic jars and got a hold of tools on first run they will attempt to knock out bridge plug tomorrow if cable company can install new sand line on rig. |
1607557888 | 2012-01-26 | Salt Water Injection Well | No Violations | On site to witness the packer and tubing run into the well. The first packer would not test so decision was made to aquire a second packer and run it in well. They plan on setting and testing the new packer tomorrow. |
1632639188 | 2014-09-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that three company owned tankers were unloading at the facility during my inspection. |
1653160281 | 2017-08-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note:Walked flowline area to monitor for any potential leaks none were found. |
1670994569 | 2014-07-08 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that several company owned vacuum trucks were waiting to unload at facility and there was a third party company on site repairing unloading pad as requested by inspector. |
1748487897 | 2012-01-05 | Salt Water Injection Well | No Violations | On site to determine if operator has tubing leak or packer failure they had Baker Tool rep close down hole valve and they pressured up on tubing no pressure decline tubing has integrity, then we pressured up on annulus and pressure declined it was determined that fluids were leaking by packer they are making plans on getting snubbing unit on site to remove tubing and packer and replace packer and tubing next week. |
1764069429 | 2016-09-29 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection and workers were on site replacing liner on the outer slope of containment wall and once secured they will cover it with stone to help prevent exposure to ultraviolet rays. |
1802111980 | 2017-12-06 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that one Oil Haulers tanker was offloading during my inspection.
Note: Well pressure is near maximum allowable pressure. |
1807095197 | 2017-02-17 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation and facility was recently cleaned up and filters were in there proper place within the roll off box that is on site. |
1825222284 | 2016-05-18 | Salt Water Injection Well | No Violations | Stopped by site for update on service rig moving in to repair said well they have 12# brine coming to try and kill well tomorrow. |
1826208093 | 2013-10-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that there are several exposed spots on liner that need to be covered with stone and it was noted that there are several 3&4 valves in need of plugs placed in them when not in use and number three cylinder on injection pump is in need of repair and unloading pad is in need of repair as we discussed. |
1851417664 | 2015-12-16 | Salt Water Injection Well | No Violations | Inspection on this day indicated that injection pump was in operation and it was noted that annulus pressure on tubing was higher pressure than previous inspections contacted company rep and discussed that they could possibly have a problem with packer or tubing or possibly the seal on the on/off tool. |
1861687283 | 2019-02-14 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump is being repaired/replaced and operator stated that they were going to change out barrel on pump two also. |
1862396247 | 2018-05-31 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspecting and it was noted that two company owned tankers were offloading at the site during my inspection. |
1873522700 | 2014-12-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that three company owned tankers were unloading at the facility during my inspection. |
1877858963 | 2009-12-14 | Salt Water Injection Well | No Violations | Inspection revealed that owner is currently in process of having storage tanks cleaned out and pump was in operation during my inspection.
Note: Stone is needed on driveway to unloading pad it will help eliminate tracking mud onto state highway and creating safety hazard. |
1878819245 | 2016-05-25 | Salt Water Injection Well | No Violations | On site to witness new Baker A-3 Lok Set packer and 2.875 tubing start in well we ran approximately 2500 of tubing this evening and run the rest tomorrow and perform MIT test. |
1884873517 | 2016-03-18 | Salt Water Injection Well | No Violations | Inspection today revealed that the well is still down waiting on owner to repair(replace tubing/packer) company rep states that they plan on working on said well in April. |
1891307927 | 2011-03-15 | Salt Water Injection Well | No Violations | On site to witness acid job on injection well, Producers Services pumped 2000 gal of 15%HCL into well and we left well shut in and they will resume operations tomorrow. |
1897140332 | 2017-09-07 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during our inspection.
|
191109629 | 2008-12-4 0:00: | SW | No Violations | |
194115552 | 2020-1-14 0:00: | SW | No Violations | |
1948211525 | 2011-12-19 | Salt Water Injection Well | No Violations | Stopped by site to check with operator to comfirm that they were making plans on building up back wall of unloading pad too secure water from going over back wall and getting in to local stream. |
194840039 | 2018-8-15 0:00: | SW | No Violations | |
1953711070 | 2016-02-03 | Salt Water Injection Well | No Violations | Well is still down waiting on service rig to replace tubing/packer in well. |
1958707235 | 2016-05-31 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time they are waiting on variance for packer setting depth. |
196108491 | 2016-8-25 0:00: | SW | No Violations | |
1966013636 | 2015-02-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that one company owned tanker was unloading at the facility during my inspection. |
1969175373 | 2009-09-18 | Salt Water Injection Well | No Violations | Inspection revealed that well is in operation,pump was in operation during my inspection and company truck was unloading at facility during my inspection.
Also noted that stone has not been applied to lease road as suggested on my last inspection. |
1984160823 | 2010-10-06 | Salt Water Injection Well | No Violations | Inspection revealed that pump was not in operation during my inspection, noted that new pump house is nearly constructed and storage tanks have been painted and according to well tender stone for covering liner is too be applied in the near future. |
2040766803 | 2013-07-17 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform acid job on well they pumped 2000 gal of 15% acid and then displaced it into formation and let it soak for 15 minutes then resumed displacement of fluid into formation average treating pressure was 1640 psi and ISIP was noted@1140 psi and after 10 minutes it was 1117 psi,rigged down Producers and operator was going to let well rest the remainder of the day before they start to injecting fluids again. |
2043421804 | 2008-10-02 | Salt Water Injection Well | No Violations | No violations noted ,facility appears to be in satisfactory condition this inspection.
Pump was in operation during my inspection,disturbed area around wellhead has been graded and seeded&mulched awaiting vegetation to be established old production tank site has been graded and seeded&mulched also,well owner still needs to place stone on lane to wellhead. |
2046490908 | 2019-02-05 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection. |
2047260937 | 2016-01-14 | Salt Water Injection Well | No Violations | Inspection revealed that well is down waiting on service rig to release packer and pull from well, suspect packer element failure or possible hole in tubing.
Note: Talked to company rep stating that it could possibly be three weeks from today until they move rig onto site and company still needs to address dike capacity issues at the site. |
2095979510 | 2018-07-09 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operatin during my inspection and it was noted that three company owned tankers were on site during my inspection. |
2101059174 | 2015-08-13 | Salt Water Injection Well | Violations Noted | Inspection revealed that injection pump was in operation today and there was three company owned vacuum trucks unloading during our inspection.
Note: Measured dike to check calculation on volumes and it was discovered that dike will not hold tank volume in the event of a major tank failure, there is 22-400 bbl. Tanks connected at the bottom which equals 8800 bbl. And calculated volume of dike is only 2800 bbl. Capacity which leaves a 6000 bbl. shortage of volume needed to contain total tank capacity. SUBMIT PLAN WITHIN 30 DAYS TO DIVISION ON HOW YOU PLAN ON REMOVING TANKS/REPLUM OR REWORK DIKE SO IT WILL HOLD VOLUME OF ALL TANKS THAT ARE CONNECTED AT THE BOTTOM |
2102968699 | 2017-01-11 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation prior to Baker-Hughes performing 825 gallon acid treatment on said well.
Note: four FQ Energy vacuum trucks were unloading at the facility during my inspection and also Myers had three tankers on site also. |
2133566655 | 2014-04-23 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that several tankers were waiting in line preparing to unload at facility. |
256642301 | 2009-8-14 0:00: | SW | No Violations | |
273405765 | 2011-5-19 0:00: | SW | No Violations | |
280413014 | 2012-10-23 0:00 | SW | No Violations | |
287621448 | 2016-10-13 0:00 | SW | No Violations | |
352117884 | 2016-5-21 0:00: | SW | No Violations | |
383651968 | 2008-9-17 0:00: | SW | No Violations | |
399130625 | 2010-11-3 0:00: | SW | No Violations | |
425883466 | 2019-5-6 0:00:0 | SW | No Violations | |
430056563 | 2017-12-28 0:00 | SW | No Violations | |
478374554 | 2008-11-4 0:00: | SW | No Violations | |
503432940 | 2004-1-2 0:00:0 | PW | No Violations | |
524226825 | 2011-4-4 0:00:0 | SW | No Violations | |
530109804 | 2015-1-5 0:00:0 | SW | No Violations | |
536961246 | 2016-7-21 0:00: | SW | No Violations | |
554229073 | 2013-12-20 0:00 | SW | No Violations | |
564011652 | 2018-2-16 0:00: | SW | No Violations | |
654179569 | 2019-4-26 0:00: | SW | No Violations | |
656479452 | 2019-5-3 0:00:0 | SW | No Violations | |
697443642 | 2011-1-14 0:00: | SW | No Violations | |
699493546 | 2018-1-4 0:00:0 | SW | No Violations | |
700037772 | 2009-4-28 0:00: | SW | No Violations | |
74062113 | 2015-2-24 0:00: | SW | No Violations | |
835876322 | 2009-1-5 0:00:0 | SW | No Violations | |
851438863 | 2019-3-7 0:00:0 | SW | No Violations | |
860190599 | 2014-11-10 0:00 | SW | No Violations | |
863350815 | 2019-9-5 0:00:0 | SW | No Violations | |
943459927 | 2017-3-23 0:00: | SW | No Violations | |
963030536 | 2016-4-12 0:00: | SW | No Violations | |
981890097 | 2019-4-12 0:00: | SW | No Violations | |
987164803 | 2016-11-8 0:00: | SW | No Violations | |
998063299 | 2018-7-20 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0564011652 | US-OH-126334 | 2018-03-27 | NONE | Failure to report disposal fees |
0965290152 | US-OH-130972 | 2016-04-04 | Failure to file salt water injection annual report | |
1373829259 | US-OH-111066 | 2018-03-27 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
2101059174 | US-OH-121473 | 2016-11-21 | Pits not liquid tight/Improper construction or use |
For data sources see[9]