X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-24071

Well Details

Well ID: 34-121-24071
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Jackson Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: REASONERS RUN PART
License Status: Producing
License Date: 2004-01-15
Spud Date: 2004-02-04
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 2004-02-09
Well Total Depth: 2155.00 ft
Configuration: Vertical
Latitude: 39.630000
Longitude: -81.550000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-01-15 Proposed Formations:BEREA-GORDON, Issued Date:1/15/2004, Expired Date:1/14/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-02-04 RBDMS Rec
Completed 2004-02-09 RBDMS Rec
Reached Total Depth 2004-02-09 RBDMS Rec
Completion Report Received 2004-12-10 RBDMS Rec
Construction Permit Expires 2005-01-14 RBDMS Rec
Change of Owner 2013-08-05 Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 1634, NORTHWOOD ENERGY CORP
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-02-01 1768 1811 7
2005-02-01 1678 1685 20
1678 1685 20
1768 1811 7
1825 1906 9
1956 2049 15
1678 1685 20
2005-02-01 1956 2049 15
2005-02-01 1825 1906 9

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 43700 Gal 30000
H2O 0 0 0
H2O 20 1800 Gal 10000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 OHIO L & M CO INC 1413.00 438.00 196
2005 OHIO L & M CO INC 3174.00 428.00 365
2006 ALLIANCE PETROLEUM CORPORATION 1885.00 191.00 365
2007 ALLIANCE PETROLEUM CORPORATION 1186.00 170.00 365
2008 ALLIANCE PETROLEUM CORPORATION 772.00 57.00 365
2009 ALLIANCE PETROLEUM CORPORATION 611.00 96.00 365
2010 ALLIANCE PETROLEUM CORPORATION 589.00 165.00 365
2011 ALLIANCE PETROLEUM CORPORATION 390.00 46.00 365
2012 ALLIANCE PETROLEUM CORPORATION 398.00 76.00 366
2013 ALLIANCE PETROLEUM CORPORATION 208.00 28.00 243
2014 NORTHWOOD ENERGY CORP 221.00 76.00 365
2015 NORTHWOOD ENERGY CORP 369.00 13.00 365
2016 NORTHWOOD ENERGY CORP 394.00 44.00 365
2017 NORTHWOOD ENERGY CORP 439.00 13.00 365
2018 NORTHWOOD ENERGY CORP 401.00 50.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 OHIO L & M CO INC Brine 0 196
2005 OHIO L & M CO INC Brine 0 365
2006 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 NORTHWOOD ENERGY CORP Brine 25 365
2014 NORTHWOOD ENERGY CORP Brine 45 365
2015 NORTHWOOD ENERGY CORP Brine 103 365
2016 NORTHWOOD ENERGY CORP Brine 20 365
2017 NORTHWOOD ENERGY CORP Brine 29 365
2018 NORTHWOOD ENERGY CORP Brine 4 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1100634906 2013-9-5 0:00:0 PW No Violations 1.00
-337377790 2004-10-14 0:00 PL No Violations
0337377790 2004-10-14 Preliminary Restoration No Violations Restoration satisfactory,pit has been filled in and vegatation established.
1100634906 2013-09-05 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing, 1.5 tubing, rods, and a pump jack. All production valves are open. The tank battery consists of one 210 bbl tank, one 50 bbl plastic tank, a separator, and a meter. A small compressor is also located inside a proper dike. The identification is proper.

For data sources see[9]

References