Well Details

Well ID: 34-121-24083
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Jefferson Township
Operator Name: TRIAD HUNTER LLC
Well Pad ID:
Farm/Lease Name: TURNER UNIT
License Status: Producing
License Date: 2004-05-06
Spud Date: 2004-05-20
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 2004-05-27
Well Total Depth: 6311.00 ft
Configuration: Vertical
Latitude: 39.640000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-05-06 Proposed Formations:DEVONIAN SHALE THRU MEDINA, Issued Date:5/6/2004, Expired Date:5/6/2005 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-05-20 RBDMS Rec
Completed 2004-05-27 RBDMS Rec
Reached Total Depth 2004-05-27 RBDMS Rec
Completion Report Received 2004-09-03 RBDMS Rec
Construction Permit Expires 2005-05-06 RBDMS Rec
Change of Owner 2010-03-24 Operator changed from 2348, TRIAD RESOURCES INC to 8610, TRIAD HUNTER LLC
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-10-27 5982 6008 32
2004-10-27 6110 6118 32
5982 6008 32
6110 6118 32
5982 6008 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2205 Bbl 36000 1000 GALLONS HCL ACID
H2O 15 644 Bbl 30000 1500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 TRIAD RESOURCES INC 10970.00 0.00 365
2005 TRIAD RESOURCES INC 14827.00 0.00 365
2006 TRIAD RESOURCES INC 4600.00 0.00 365
2007 TRIAD RESOURCES INC 0.00 0.00 365
2008 TRIAD RESOURCES INC 3806.00 0.00 365
2009 TRIAD RESOURCES INC 3348.00 0.00 365
2010 TRIAD RESOURCES INC 2844.00 0.00 365
2011 TRIAD HUNTER LLC 2155.00 0.00 365
2012 TRIAD HUNTER LLC 3081.00 0.00 366
2013 TRIAD HUNTER LLC 1609.00 0.00 365
2014 TRIAD HUNTER LLC 1474.00 0.00 365
2015 TRIAD HUNTER LLC 2013.00 0.00 365
2016 TRIAD HUNTER LLC 2090.00 0.00 366
2017 TRIAD HUNTER LLC 2099.00 0.00 365
2018 TRIAD HUNTER LLC 1059.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 TRIAD RESOURCES INC Brine 0 365
2005 TRIAD RESOURCES INC Brine 860 365
2006 TRIAD RESOURCES INC Brine 0 365
2007 TRIAD RESOURCES INC Brine 0 365
2008 TRIAD RESOURCES INC Brine 0 365
2009 TRIAD RESOURCES INC Brine 0 365
2010 TRIAD RESOURCES INC Brine 0 365
2011 TRIAD HUNTER LLC Brine 0 365
2012 TRIAD HUNTER LLC Brine 143 366
2013 TRIAD HUNTER LLC Brine 0 365
2014 TRIAD HUNTER LLC Brine 80 365
2015 TRIAD HUNTER LLC Brine 82 365
2016 TRIAD HUNTER LLC Brine 330 366
2017 TRIAD HUNTER LLC Brine 0 365
2018 TRIAD HUNTER LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1412335315 2004-6-11 0:00: PW No Violations
-1627125050 2004-5-27 0:00: PW No Violations
-1904368084 2009-5-7 0:00:0 PW No Violations
-303773855 2018-10-25 0:00 PW No Violations 1.00
-851371144 2004-8-2 0:00:0 PL No Violations
0303773855 2018-10-25 Production Wells No Violations On the day of my inspection I witnessed production equipment included a 100-barrel production fluid tank, horizontal separator, drip and 2-inch diameter meter run with 1.125-inch diameter orifice, there was a 3-inch diameter load line ran through the dike and to the road. The well was equipped with 11.75-inch diameter conductor, 8.625-inch diameter surface casing, 4.5-inch diameter production casing, 1.5-inch diameter tubing equipped with a plunger lift system. The casing valve was closed, tubing valve was open, but flow line valve was closed. It appeared that surface casing was open to atmosphere at the time of my inspection. The well appeared to be shut in at the time of my inspection. The Production equipment was all contained within an earthen dike. There was identification on the production equipment but not on the well equipment, and production was reported for 2017.
0851371144 2004-08-02 Preliminary Restoration No Violations Received call from Cambridge Office reguarding restoration issues on well called Kein Weaver at Triads office and discussed issues at well site informed him that restoration needed to be completed by Sept 15 2004.he stated that he had a contractor lined up to complete restoration and install drainage system(French) to help eliviate erosion on site.
0881807812 2012-10-30 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing, 1.5 tubing, and a plunger lift system. The tank battery consists of one 100 bbl tank, a meter, and a separator. The equipment is located in a dike, and has proper identification.
1085604711 2004-05-20 Drill / Deepen / Reopen No Violations Stopped by drill rig for update on up coming surface job rig crew waiting on track hoe to dig drilling pit.
1085773735 2004-05-27 Production Wells Violations Noted Kean Weaver of Triad contacted at approximately at 12:00 Noon and was notified of the situation. Tugend required imeadiate lowering of fluid level in pit to below top of liner.
1095250572 2004-09-14 Preliminary Restoration No Violations Restoration satisfactory,this well had Chiefs Order on it issued from Central Office

recommend lifting of Chiefs Order#2004-70 Photos sent to Columbus Office.

1412335315 2004-06-11 Production Wells No Violations Follow up to NOV issued by Deputy Chief Tom Tugend for pit violations pit has since been pumped down and water hauled to disposal well.Resolved!!
1627125050 2004-05-27 Production Wells Violations Noted FOLLOW UP TO NOV # 1085773735 Kean Weaver of Triad contacted at approximately at 12:00 Noon and was notified of the situation. Tugend required imeadiate lowering of fluid level in pit to below top of liner.
1904368084 2009-05-07 Production Wells No Violations Inspection this day found well producing with rabbit, tank has good IDs, good dike, current chart in meter.
2086498449 2018-10-25 Production Wells No Violations On the day of my inspection I witnessed production equipment included a 100-barrel production fluid tank, vertical separator, drip and 2-inch diameter meter run with 1.00-inch diameter orifice, there were two 2-inch diameter load line ran through the dike and to the road. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, 1.5-inch diameter tubing equipped with a plunger lift system. The 2-inch diameter casing valve and tubing gate valve were closed at the time of my inspection. The well did not appear to be producing at the time of my inspection. The Production equipment was not contained within an earthen dike. There was identification on the production equipment but not on the well equipment, and production was reported for 2017.
881807812 2012-10-30 0:00 PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1085773735 US-OH-101965 2004-05-28 Dike or pit not able to prevent escape of brine or other wastes
1627125050 US-OH-115998 2004-05-28 Dike or pit not able to prevent escape of brine or other wastes

For data sources see[9]