X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-24197

Well Details

Well ID: 34-121-24197
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Elk Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: B & N COAL/MM
License Status: Producing
License Date: 2006-06-29
Spud Date: 2006-07-07
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 2006-07-13
Well Total Depth: 3225.00 ft
Configuration: Vertical
Latitude: 39.680000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-29 Proposed Formations:BEREA-GORDON, Issued Date:6/29/2006, Expired Date:6/29/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2006-07-07 CORRECTION TO ELEVATION, SHOULD BE 730' AND CORRECTION TO SECTION, SHOULD BE 24 (N).
Original Spud 2006-07-07 RBDMS Rec
Completed 2006-07-13 RBDMS Rec
Reached Total Depth 2006-07-13 RBDMS Rec
Completion Report Received 2006-11-22 RBDMS Rec
Construction Permit Expires 2007-06-29 RBDMS Rec
Change of Owner 2015-07-10 Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 9086, GENESIS RESOURCES LLC
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-01-22 2043 2079 20
2007-01-22 1892 1930 20
1747 1801 17
1892 1930 20
2043 2079 20
2844 2870 12
2971 3047 9
3138 3166 12
1747 1801 17
2007-01-22 1747 1801 17
2007-01-22 3138 3166 12
2007-01-22 2971 3047 9
2007-01-22 2844 2870 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 25000 Gal 7500 FOUR STAGE FRAC…25M GALLONS WATER & 7500# SAND PER STAGE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION 615.00 0.00 365
2008 ALLIANCE PETROLEUM CORPORATION 146.00 0.00 365
2009 ALLIANCE PETROLEUM CORPORATION 7.00 0.00 365
2010 ALLIANCE PETROLEUM CORPORATION 51.00 0.00 365
2011 ALLIANCE PETROLEUM CORPORATION 323.00 0.00 365
2012 ALLIANCE PETROLEUM CORPORATION 147.00 0.00 366
2013 ALLIANCE PETROLEUM CORPORATION 55.00 0.00 365
2014 ALLIANCE PETROLEUM CORPORATION 290.00 0.00 365
2015 GENESIS RESOURCES LLC 92.00 0.00 184
2016 GENESIS RESOURCES LLC 287.00 0.00 323
2017 GENESIS RESOURCES LLC 145.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2015 GENESIS RESOURCES LLC Brine 0 184
2016 GENESIS RESOURCES LLC Brine 0 323
2017 GENESIS RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1213090977 2020-6-11 0:00: PW No Violations
-1927135254 2012-5-29 0:00: PW No Violations
0275820332 2013-07-18 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing, 1.5 tubing, rods, and a pump jack. The tank battery consists of one 100 bbl tank, a 50 bbl plastic tank, a separator, and a meter all located in a dike. The identification is proper.
0873709540 2016-03-10 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing, 1.5 tubing and a pumping unit. The production valves are open at the time of inspection. The tank battery is comprised of two 210 barrel tanks, one 100 barrel tank, two separators and two meters with current charts. The tank battery is shared by multiple wells.
1164994704 2006-11-28 Preliminary Restoration No Violations Restoration work at site satisfactory, well is equipped with pumping unit and tubing&rods and 1-100 bbl tank with dike in place.
1846278564 2014-02-11 Production Wells No Violations My inspection finds the well is equipped with 4.5 casing, tubing, rods, and a pump jack. The tank battery consists of one 100 bbl tank, a 50 bbl plastic tank, a separator, and a meter all located in a dike. The identification is proper. The ground is covered at the time of inspection.
1927135254 2012-05-29 Production Wells No Violations Inspection of the well head found the following -4.5 production casing -1.5 tubing with the production valves open and the well being produced by the means of a pumping unit. A 100 barrel tank -1600 gallon plastic tank -separator and gas meter with a current chart are present in an established dike with proper well identification.
275820332 2013-7-18 0:00: PW No Violations 1.00
873709540 2016-3-10 0:00: PW No Violations 1.00

For data sources see[9]

References