34-121-24405

Well Details

Well ID: 34-121-24405
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Enoch Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-000580
Farm/Lease Name: NORTHSTAR W EN NBL 33
License Status: Producing
License Date: 2013-01-30
Spud Date: 2013-02-05
Spud Drilling Contractor: NABORS DRILLING
Final Drill Date: 2013-05-26
Well Total Depth: 13199.00 ft
Configuration: Horizontal
Latitude: 39.730000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-02-01 Proposed Formations:POINT PLEASANT, Issued Date:2/1/2013, Expired Date:2/1/2015 12:00:00 PM, Drilling unit acres:147.28, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2013-05-26
Construction Permit Expires 2015-01-30
Correction to Well 2016-01-01 change in acreage, surface footage, target/takepoint per as-drilled plat-ALE
Completion Report Received 2016-08-02
Change of Owner 2018-09-20 Operator changed from 8441, CNX GAS COMPANY LLC to 9520, ASCENT RESOURCES UTICA LLC
Correction to Well 2018-10-22 CHANGE IN WELL NAME AND NUMBER. PREVIOUS--RESERVE COAL PROPERTIES CO #NBL33AHSUA.
Record Last Modified 2018-10-25

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/16/2013 12/31/2013 7936 9,180,250.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1
and (Proppant), DAP-103, DAP-903,

DWP-111, DWP-125, DWP-614, DWP-901, BioClear 2000, DWP-NE1, Spearh

CWS Propping Agent, Iron Control, Scale Inhibitor, Gel Slurry, Crosslinker, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations, Calcite 471-34-1 1 0.0153 13025.8
Potassium hydroxide 1310-58-3 10 0.0001 78.19
Sorbitan monooleate 1338-43-8 5 0.003 2579.81
Biotite 1302-27-8 0.1 0.0008 719.08
Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.003 2579.81
Ammonium Persulfate 7727-54-0 100 0.002 1689
Polyethylene Glycol Mixture 25322-68-3 70 0.0126 10707
Sodium chloride 7647-14-5 0.1 0.0001 65
Ilmenite 98072-94-7 0.1 0.0001 98.8
Crystalline silica (Quartz) 14808-60-7 100 7.3959 6,295,040.0
Dimethylcocoamine, bis(chloroethyl)

ether, diquaternary ammonium salt

68607-28-3 40 0.0006 552.44
Goethite 1310-14-1 0.1 0.0023 1959.63
Alcohols, C14-15, ethoxylated 68951-67-7 0.1 0.0023 1949.97
Fatty acids, tall-oil 61790-12-3 0.1 0.0023 1949.97
Citric Acid 77-92-9 60 0.005 4240.53
Diallyldimethylammonium chloride 7398-69-8 5 0.0001 69.06
2-Propenoic acid, polymer with sodium phosphonate 71050-62-9 60 0.0068 5766.49
Alkenes, C>10 a- 64743-02-8 0.1 0.0023 1949.97
Illite 12173-60-3 1 0.0003 266.76
Apatite 64476-38-6 0.1 0.0008 719.08
2-Propenoic acid, polymer with 2-propenamide, sodium salt 25987-30-8 40 0.0242 20638.5
Hydrochloric acid 7647-01-0 35 0.5346 454993
Guar gum 9000-30-0 60 0.1319 112283
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 40 0.0126 10707
Distillates (petroleum), hydrotreated middle 64742-46-7 60 0.1501 127762
Formaldehyde 50-00-0 0.1 0.0002 130
Quaternary ammonium compounds,

bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite

68953-58-2 5 0.011 9356.9
Propargyl Alcohol 107-19-7 0.1 0.0008 649.99
Methanol 67-56-1 15 0.0048 4107.11
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.5 0.0033 2807.07
Sodium tetraborate pentahydrate 12179-04-3 40 0.0004 312.75
Isopropanol 67-63-0 40 0.0006 552.44
Modified thiourea polymer 68527-49-1 0.1 0.0023 1949.97
Water, Customer & CWS Base Fluid & Mix Water, Water 7732-18-5 100 91.6675 78,022,900.0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CNX GAS COMPANY LLC 372652 20633 264
2015 CNX GAS COMPANY LLC 278107 9604 356
2016 CNX GAS COMPANY LLC 176769 3499 289
2017 CNX GAS COMPANY LLC 157355 3571 360
2018 ASCENT RESOURCES UTICA LLC 121450 2196 330
2019 ASCENT RESOURCES UTICA LLC 30521 622 90

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CNX GAS COMPANY LLC Brine 21771 264
2015 CNX GAS COMPANY LLC Brine 5435 356
2016 CNX GAS COMPANY LLC Brine 3800 289
2017 CNX GAS COMPANY LLC Brine 3493 360
2018 ASCENT RESOURCES UTICA LLC Brine 1960 330
2019 ASCENT RESOURCES UTICA LLC Brine 172 90

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-106565087 2013-3-4 0:00:0 DD No Violations 1.00
-443565406 2015-6-18 0:00: PW No Violations 3.00
-775732539 2015-6-16 0:00: PW No Violations 3.00
0106565087 2013-03-04 Drill / Deepen / Reopen No Violations The rig is currently drilling at a depth of 4725 with a hammer.
0294944187 2016-01-13 Production Wells No Violations At 11:42 am, I received a telephone call from Jamie Kominich indicating that a small glycol release occurred on the NBL 33 well pad sometime between 6:00 and 9:00 am. I arrived on location at 12:23 pm. The site was covered in three inches of snow. I inspected the site and found an area approximately 12 by 15 with the snow melted from the surface. Around the melted area a 3 wide band of snow was discolored pink by the atomized mist. I spoke to Cody Craker a CNX employee and he stated that the cause of the release was human error. Mr. Craker indicated that T-K personnel set the Kimray T-12 temperature control regulator too high, causing the over pressurization of the production unit heating vessel, resulting in the release. The estimated total of material (50/50 glycol/water) lost is three to five gallons, with all material remaining on site. I instructed the company to remove all contaminated soil and properly dispose of the material. The company will turn over a copy of the waste manifest as soon as possible. Work on the site is estimated to be completed by the end of the day.
0443565406 2015-06-18 Production Wells No Violations My inspection today finds the fuel gas line that was the cause of the fire has been disconnected and the point of failure has been dug up. The gas line ruptured in the steel to plastic transition. The fuel line is no longer needed and will not be replaced.
0566305987 2017-03-09 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with valves in the open position. Gauges present read 400 pounds per square inch on the casing and 200 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consisted of three sand traps, three gas production units, six 400 barrel tanks, and one combustor. Identification was present and production records were current.
0775732539 2015-06-16 Production Wells No Violations A fire was discovered at the NBL 33 well pad by U.S.A. Compression personnel. The well pad was shut in at the time of the discovery due to high line pressure. Upon finding the fire, the Emergency Shut Down was activated; however, the fire did not stop. The Caldwell Volunteer Fire Dept. was called at 3:00 pm and arrived onsite at 3:16 pm. Fire Chief Reed stated that a fire was emanating from under the ground. The Fire Dept. sprayed the low pressure separator adjacent to the fire to keep it cool, until Bill Palmer with TK Services shut in the fuel gas line and the Vapor Recovery Unit line. Once those valves were closed the fire went out. I arrived on scene at 4:22 pm and the fire was out.

My inspection of the area finds no visible signs of contamination from liquid hydrocarbons. The fire occurred between a low pressure separator and a glycol line heater. The hole in the ground where the fire was burning is directly adjacent to the fuel gas line and is a likely source.

0968978508 2016-03-15 Production Wells No Violations My inspection today finds the RBS Wireline Service is onsite to install a bumper spring and plunger lift system. The tank battery is comprised of six 400 barrel tanks set inside of a plastic lined steel containment.
1194155413 2013-11-19 Preliminary Restoration No Violations The well site meets the preliminary restoration criteria.
1198886196 2013-06-20 Drill / Deepen / Reopen No Violations My inspection today finds the operator is building a large tank impoundment, they have adequate sediment controls in place.
1213537230 2017-08-08 Production Wells No Violations The purpose of my inspection today was a status check on a production well. During my inspection the well was equipped with plunger lift system with production valves in the open position. The production casing had a gauge present reading 363 pounds per square inch and the production tubing had a gauge present reading 300 pounds per square inch. The production equipment consisted of six 400 barrel tanks, three sand traps, three gas production units, and one combustor. The natural gas pipeline tie in was located on the south side of the pad. The identification was posted by the wellhead.
1361988458 2013-02-25 Drill / Deepen / Reopen No Violations I am onsite to witness Cal-Frac cement 2149 of 13.375 casing. I witnessed 25 bbl of cement returns to surface.
1363341241 2013-03-14 Drill / Deepen / Reopen No Violations I am onsite to review proposed cementing plan for the 9.625 casing string. Cal-Frac is rigging up their cement head and preparing to cement the first stage of the job.
1363622319 2013-03-15 Drill / Deepen / Reopen No Violations My inspection today finds Cal-Frac is cementing the second stage of the 9.625 casing. They are using 1143 sacks of class A cement. I witnessed 35 bbl of cement return to surface.
1459391599 2018-09-20 Production Wells No Violations The purpose of my inspection today was a status check. During my inspection the well was equipped with plunger lift system with production valves in the open position. Annular pressure monitoring was present with valves reading 0 pounds per square inch. The production equipment consisted of six 400-barrel tanks, three sand traps, three gas production units, and one combustor. The natural gas pipeline tie in was located on the south side of the pad. The identification stated CNX Gas Company. Ascent will have 60 days after the transfer date to post identification.
294944187 2016-1-13 0:00: PW No Violations 2.00
566305987 2017-3-9 0:00:0 PW No Violations 0.50
968978508 2016-3-15 0:00: PW No Violations 1.00

For data sources see[8]

References